SJ45 AJ+, SJ60 AJ+
238264AAA
57
Function tests
Section 4 – Inspections Before Operation
14.
Press the
sensor bar
for less than 1 second and
then release it.
▪
Result:
The function will stop while the bar is
pressed, and the function will continue when
the bar is released. The audible/visual alarm
goes on while the bar is pressed and goes off
after it is released. The reset button illuminates
when the bar is pressed and goes off when the
bar is released.
15.
Press the
sensor bar
for more than 1 second
and then release it.
▪
Result:
The function will stop, and the audible/
visual alarm goes on immediately and stays
on after the bar is released. The engine stops
after 1 second. The reset button illuminates.
16.
While the
audible/visual alarm
7
is on, make
sure the LED strobe light is also on.
4.3-12 Do a test of the engine start/on/off
switch
1.
Make sure the engine is on.
2.
Select the off position from the
engine start/on/
off
8
switch.
▪
Result:
The engine stops and the platform
control console is disabled.
3.
Select the on position from the
engine start/on/
off
switch.
▪
Result:
The platform control console is
enabled.
4.
Select the start position from the
engine start/
on/off
switch to start the engine.
TM
1
2
+
+
7
8
To
order
go
to
Discount-Equipment.com