background image

SkyeReader 300 User Guide

17

Copyright 2009 SkyeTek, Inc. All Rights Reserved.

o

RF—keep the RF detection field activated after the command
executes

o

AFI—the command will use the Application Field Identifier
(AFI) field to select tags

o

Session—use the Session Field to select tags

o

CRC—CRC required for the request or response

o

TID—Tag ID (TID) present in the request

o

RID—Reader ID (RID) present in the Request (see Reader field
above)

o

Encryption—write or read data will be encrypted

o

HMAC—verify the HMAC for read and write commands

o

Data—data is present in the command

(Required flags for each command and flag combinations are
described in the SkyeTek Protocol v3 Reference Guide.)

Tag parameters:

o

Type—Specifies the type of tag with which the reader module
communicates (select from pull-down list)

o

AFI value—specifies the Application Field Identifier (AFI) used
to detect a tag in the RF field

o

Session—specifies the session number to be used with a series of
commands

o

TID—specifies the tag ID to which the command is directed

o

TID Length—the length of the Tag ID

o

Memory parameters:

o

Address—specifies the address

o

Blocks—specifies the amount of data to be written by or read
from the reader module. (The location of the data is specified by
the Address field.)

o

Data—the data being sent with the command

o

Data Length— the exact number of bytes required by the data
field

o

Mode (binary or ASCII)

o

Length—the length of the command in bytes (automatically
calculated)

o

CRC (automatically calculated; mandatory in binary mode, and
optional in ASCII mode)

4.  Click the Send button to send the command to the reader to be executed. The

response is displayed in the Response area.

You can also:

Click the Clear button to clear the screen and reset the screen to its default
values.

Содержание SkyeReader 300

Страница 1: ...SkyeReader 300 User Guide v1 0...

Страница 2: ...t 2009 SkyeTek Inc All Rights Reserved Technical Support and Contact Information SkyeTek Inc 11030 Circle Point Road Suite 300 Westminster CO 80020 http www skyetek com Sales sales skyetek com Technic...

Страница 3: ...SkyeReader 300 User Guide 3 Copyright 2009 SkyeTek Inc All Rights Reserved Error No table of contents entries found...

Страница 4: ...ay not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply w...

Страница 5: ...eTek readers Chapter 2 Setup and Installation Lists the contents of the SkyeReader 300 kit and guides you through initial setup and configuration of your system Provides instructions for installing th...

Страница 6: ...wing items The SkyeReader 300 USB cable CD with SkyeWare documentation and software libraries Tag Samples Setting Up Your SkyeReader 300 To setup your SkyeReader 300 first you will need to install Sky...

Страница 7: ...kyeReader and you are ready to go Note that any tags in the field will also be displayed Note also that under Readers the display will read SkyeReader 300 USB 4 To read a tag place an EPC Class 1 Gene...

Страница 8: ...creen After Reader Setup Capabilities Tab This tab contains sub tabs that let you perform high level demonstrations of the basic functionality of your SkyeReader This includes Read Range lets you test...

Страница 9: ...eserved Configuration Tab Sub tabs for this tab let you quickly update firmware and configure tag settings Firmware allows you to reload or upgrade SkyeReader 300 firmware Tag lets you configure tag f...

Страница 10: ...tures of your SkyeReader SkyeWare 4 recognizes the reader and firmware and adjusts the demonstration functions accordingly This chapter discusses each demonstration function SkyeWare 4 Capabilities Ta...

Страница 11: ...the detection range c Use the up or down arrows in the Modulation Depth field to adjust the percentage for the modulation depth in increments of 10 or type a number between 0 and 100 directly into the...

Страница 12: ...hen the Anti Collision sub tab Anti Collision Demonstration Function How to Use 1 Optional To limit this function to specific tags select a tag type from the pull down menu The default value is Auto D...

Страница 13: ...field to a corresponding number b Use the up or down arrows in the Command Retries field to match the number set the number of times the reader will repeat the command before timing out This automati...

Страница 14: ...icator that the memory is being read Note The specific fields displayed for the tag memory display depend on the memory layout of the tag you use for this demonstration 2 Optional If you are using mul...

Страница 15: ...ible tag c Click Open This loads the stored memory onto the current tag If the file is incompatible with the tag for example if the file has more memory than the tag can hold the read operation fails...

Страница 16: ...le reader for reader specific examples of using STPv3 commands Protocol Panel How to Use To execute a command 1 Click on the arrow next to the Command field This displays a pull down list of all reade...

Страница 17: ...ll down list o AFI value specifies the Application Field Identifier AFI used to detect a tag in the RF field o Session specifies the session number to be used with a series of commands o TID specifies...

Страница 18: ...reference guide for your SkyeModule reader for the address number of blocks and valid data values for different system parameters Select whether data is transmitted in ASCII or binary format when usi...

Страница 19: ...SkyeWare Configuration Overview SkyeWare 4 s Configuration tab lets you easily customize the full functionality of the SkyeReader 300 and the tags it supports This chapter discusses each configuration...

Страница 20: ...the Firmware sub tab Firmware Configuration Panel How to Use 1 Check the SkyeTek support portal at support skyetek com for announcements of updates to the SkyeModule M2 M4 M7 or M9 firmware SkyeTek wi...

Страница 21: ...information by querying the reader again The personality is displayed on the Firmware Configuration panel title and information box 9 Check the display area to verify that the new firmware informatio...

Страница 22: ...able for that tag type How to Use UHF tags 1 Place a configurable tag in the read field SkyeWare The screen displays the configurable fields for the tag 2 Specify new values using the editable fields...

Страница 23: ...ad only Displays the tag Class Mask and Model Memory Locks lets you set access permissions for the access and kill passwords and for the EPC TID and User memory banks For example you can configure the...

Отзывы: