-51-
Adjustment
(5) DC-DC Pack Voltage Set up Range
Vsetup : 210V ~ 240V
Vsc : 90V ~ 120V
-Vy : -60V ~ -80V
-Ve : -35V ~ -45V
<Caution>
(1) The power of the signal generator should be turned on before turning on the power of DC power
supply.
(2) The voltage of DC power supply , in standard of Module input voltage, should be preset as
below.
Vcc: 5V, Va: 65V, Vs: 190V
(3) The power of power supply must turned on by this sequence. Reverse direction When turning
off.
* Module on : 5V
Va
Vs, Module off: Vs
Va
5V
(4) Signal generator should be selected with 852*480 mode(WVGA)
Содержание PDS4250
Страница 1: ...42 PLASMA PDP MONITOR CHASSIS SP 120 MODEL PDS4250 NOV 2003 ...
Страница 9: ... 8 3 BLOCK DIAGRAM ...
Страница 42: ... 41 ASSEMBLY LIST COMPONENTS PICTURE REMARK 5 FRONT MASK 6 FILTER GLASS 7 BACK COVER ...
Страница 43: ... 42 ...
Страница 54: ...Trouble Shooting 53 ...
Страница 61: ... 60 5 Block Diagram of Module ...
Страница 62: ......