background image

16

PART III : ALIGNMENT

Eyepiece

It is very important to put the alignment stars at the center (or the same spot) of the FOV of the 

telescope’s eyepiece during the alignment process. Thus,
•  It is recommended that a reticle eyepiece is used for alignment.
•  If a reticle eyepiece is not available, try to use an eyepiece with shorter focal length to yield 

a smaller FOV. Users can defocus the telescope to obtain a large star disk in the FOV. 

Centering the star disk in the FOV is easier than centering a sharp star. 

•  During the alignment process, avoid changing or rotating the eyepiece and the diagonal 

mirror.

Mechanical Backlash

All mounts have more or less mechanical backlash on both axes. To avoid introducing align-

ment error from backlash, users should keep the following rules in mind:
•  When centering an alignment star in the eyepiece, the operation should always end by 

using the 

UP

 and 

RIGHT

 direction keys to move the axes.

•  If there is overshoot when centering alignment star in eyepiece with 

UP

 or 

RIGHT

 keys, use 

the 

LEFT

 or 

DOWN

 keys to pull the star back to the edge of the FOV  and then use the 

RIGHT

 

or 

UP

 keys to center the star again.

Alignment Stars Selection

The choice of alignment stars might also impact the alignment accuracy. Please refer to

 Sec-

tion 3.7

 on the rules of choosing alignment stars for various mounts and alignment methods.

3.6  Tips for Improving Alignment Accuracy

Rules for choosing an alignment star:
•  Choose an alignment star with smaller declination. It will help to obtain higher resolu-

tion in R.A. movement in the telescope’s eyepiece.

•  If there is cone error in the telescope-mount setup or if users are not sure about it, it is 

recommended to choose an alignment star that is close to the object(s) to be observed.

Advantage: Quickest alignment.
Preconditions:
•  An accurate polar alignment for the mount.
•  Small cone error in the telescope-mount setup.  

If the cone error is large, there will be noticeable offset in the R.A. when the SynScan 

hand control locates an object which is: 

1. 

Equatorial Mount with 1-Star Alignment:

3.7  Comparison of Alignment Methods

 

»

On the other side of the meridian from the alignment star

 

»

Deviated significantly with the alignment star in declination.

Содержание AZ-EQ6 GT

Страница 1: ...INSTRUCTION MANUAL SynScan TM SSHCV3 F 141031V1 EN Copyright Sky Watcher SynScan TM...

Страница 2: ...ethod 15 3 6 Tips for Improving Alignment Accuracy 16 3 7 Comparison of Alignment Methods 16 4 1 Menu Structure 18 4 2 Accessing Menus 19 4 3 Short cut Keys 19 5 1 Locating Messier Objects 20 5 2 Loca...

Страница 3: ...Editing Date Time Coordinates Time Zones and Daylight Saving Time 28 8 2 Re aligningtheMount 28 8 3 Show Position 28 8 4 Show Time and Local Sidereal Time 28 8 5 Display Version Information 28 8 6 Di...

Страница 4: ...SC SETUP ENTER directional number shortcut keys and scroll keys A SynScan hand control and its interfaces are shown in Fig 1 1 1 1 Outline and Interface 1 2 Connecting to a Telescope Mount Fig 1 1 Con...

Страница 5: ...will be kept and the LCD display will return to the previous ones The following table lists the available speeds Rate 7 8 9 is primarily used to quickly slew a mount Rate 5 6 is primarily used to mov...

Страница 6: ...but it can only give a rough result The Easy Tracking mode is suitable for quick setup for visual observing of brighter celestial objects such as planets the moon or the sun If the user does not turn...

Страница 7: ...hand control with a firmware version 3 32 or later supports both an equatorial mount and an alt azimuth mount It is able to detect the model of the mount to which it connects and select the appropriat...

Страница 8: ...function is designed for side by side dual telescopes setup Geographic Coordinates The LCD screen will display Enter Location in the first line and display longitude and lat itude in the second line P...

Страница 9: ...olaris in the polar scope s FOV User can imagine the large circle in the FOV of a polar scope as a clock s face with 12 00 at the top and put Polaris at the HH MM position of the large circle when usi...

Страница 10: ...Scan hand control work in the Easy Tracking mode refer to Section 1 4 Step 2 Users can also start an alignment process refer to Section 8 2 to let the SynScan hand control operate in Full Feature mode...

Страница 11: ...then use the data collected in this process to transform between the mount coordinates and the sky coordinates The operating steps of aligning to alignment stars may differ depending on the type of m...

Страница 12: ...key again the LCD screen will display Exit Alignment 1 YES 2 NO Press key 1 to exit the alignment process press key 2 to go back to choose an alignment star 1 Find the brightest stars in the current...

Страница 13: ...this region If multiple bright stars appear in the list users can identify the names of the stars in the real sky by matching the azimuth altitude and magnitude provided by the SynScan hand control Pi...

Страница 14: ...Use dir keys to center object Now the telescope should point rather closely to the 2nd alignment star generally in the FOV of the finder scope 4 Now users can use the direction keys to move the telesc...

Страница 15: ...rough a list of star names and Press ENTER key to pick the one on the screen as the 2nd alignment star The mount will then automatically slew and point the telescope towards the 2nd alignment star in...

Страница 16: ...HT keys use the LEFT or DOWN keys to pull the star back to the edge of the FOV and then use the RIGHT or UP keys to center the star again Alignment Stars Selection The choice of alignment stars might...

Страница 17: ...ridian For the two alignment star on the same side of the meridian the deviation in their R A should be greater than 3 hours and the absolute value of the difference of the two alignment stars declina...

Страница 18: ...Power Voltage Polaris Pos P A Error UTILITY FUNC OBJECT LIST NGC Catalog IC Catalog Messier Catalog Caldwell Catalog SAO Catalog Double Star Variable Star User Object Deep Sky Tour Recall Object New...

Страница 19: ...short cut keys for accessing the most commonly used sub menu The short cut keys may only be used while the hand control is in stand by mode that is the SynScan hand control is not executing a specific...

Страница 20: ...y the hand control Section 11 3 The screen will display Target over slew limit in this case Users can press the ESC key to stop the mount The screen will display Mount stopped Press any key Users can...

Страница 21: ...tion is similar to that for locating Messier objects refer to Section 5 1 for details If the selected object is below the horizon at this time the SynScan hand control will display Below horizon for 2...

Страница 22: ...nitude 8 The operation is similar to that of locating Messier objects refer to Section 5 1 for de tails The operation is similar to that of locating Messier objects refer to Section 5 1 for de tails 5...

Страница 23: ...ent azimuth and altitude will be displayed in the bottom row Use the scroll keys to browse the object s J2000 celestial coordinates magnitude MAG rise time Rise transit time Transit set time Set size...

Страница 24: ...The screen will display Save 5 The screen will now display View Object Press ENTER to have the mount start slewing towards the selected object If the object is a celestial object the mount will start...

Страница 25: ...periodic error correction PEC function Applies to equatorial mounts only Note Users can turn on the tracking without doing a star alignment process In this case the polar alignment should be rather a...

Страница 26: ...with an autoguider port the SynScan hand control can change the guiding speed of the mount 1 Access the menu SETUP Auto Guide Speed and press the ENTER key 2 Use the scroll keys to choose one of the...

Страница 27: ...he ENTER key to sort the list alpha betically The alignment star s altitude must be above 15 degrees For an equatorial mount the alignment star s declination must be between 75 and 75 degrees For an a...

Страница 28: ...tailed input instructions 1 Access the menu UTILITY FUNC Show Position and press the ENTER key 2 Use the scroll keys to switch between the following coordinates Dec RA Displays the current celestial c...

Страница 29: ...nter the object to be identified in the telescope s eyepiece 8 6 Display Temperature 8 8 Display Polaris Position 8 7 Display Power Voltage 8 9 Display Polar Alignment Error Access the menu Utility Fu...

Страница 30: ...Sync Encoder Completed Press any key to exit 2 Press the ID shortcut key The screen will display Identify Searching The SynScan hand control will look up the named stars planets Messier objects NGC ob...

Страница 31: ...trophotography Note The SynScan hand control cannot work with the above application when it is in the fol lowing status When checking GPS information Section 12 2 During the PEC training process When...

Страница 32: ...skywatch er com and extract the file SynScanFirmwareLoader exe to the above folder 3 Download the latest firmware package and extract the SSF file to the above folder 1 Connect the computer and the S...

Страница 33: ...e update process failed in the middle of updating try to press the SETUP button on the SynScan hand control to use other communication speeds Mi or Lo 4 After the loading starts the application will d...

Страница 34: ...observing session Press 2 key to abandon the previous saved parked position and alignment data and start a regular observing session 11 1 Parking Telescope PART XI ADVANCED FUNCTIONS 3 The mount will...

Страница 35: ...ion Press the UTILITY shortcut key access to sub menu PAE PAE Align and then press the ENTER key Press and hold the ESC key for two seconds 4 The screen will display Center Object in the first row and...

Страница 36: ...he telescope s eyepiece Remember the reference star s current position in the eyepiece for later adjustment Press the ENTER key to confirm the centering operation 7 The screen will now display the pol...

Страница 37: ...ed to the next step The SynScan hand control can control a DSLR camera to do astrophotography It can accept 8 groups of Exposures Time Frames parameters and then controls the camera to take batch expo...

Страница 38: ...re mode 2 Press the UTILITY shortcut key access to the sub menu Camera Control Shoot and press the Enter key 3 The SynScan hand control will start to take batch exposure and display the progress data...

Страница 39: ...the position of the star in the FOV of the telescope when a user presses the Left or Right direction key on the SynScan hand control Choosing a 0 125X sidereal rate is recommended for a smaller FOV o...

Страница 40: ...to execute the au to home process 4 Finish the subsequent initialization steps 5 At the end of the initialization choose 1 star alignment to align the mount 6 At the end of the 1 star alignment the ha...

Страница 41: ...from Sky watcher product dealers Operation Details 1 Connect the camera s shutter control port to the mount or SynScan hand control with proper cables 2 Point the camera to the desired orientation 3 A...

Страница 42: ...to exit Use the left and right direction keys to move the cursor on the screen Use the scroll keys to change or switch the sign for the time zone Use for the time zones in the Eastern Hemisphere use...

Страница 43: ...s to bring the Polaris as close as pos sible to the center of the finder scope or the telescope s eyepiece 4 Fine tune the azimuth and latitude of the mount to center the Polaris in the telescope s ey...

Страница 44: ...a while for the purpose of checking the LCD display 5 If there is any problem for the RS 232C function on multi purpose port the RJ 12 outlet or no Loop Test Plug connected to the multi purpose port...

Страница 45: ...Backlight Keypad Rubber Adjustable backlight GPS SynScan GPS Modular Optional PC Connection RS 232C 9600bps No parity check 8 data bits 1 start bit 1 stop bit Power Supply DC 7 5 to 12V 100mA Power ou...

Страница 46: ...SynScan TM...

Отзывы: