- 8 -
3inch Helical Rotor Pumps Series
Over Temperature Foldback
The SK-197K1500-36 solar pump controller is designed for full power operation from a solar array in
ambient temperatures up to 45
℃
. In excess of 45
℃
temperature conditions
,
the controller will reduce output
power in an attempt to avoid shutdown. Full pump output is restored when the controller temperature cools to
a safe level.
Level Control Switch
The SK-197K1500-36 solar pump controller can access two water level switch detects remotely control
the pump automatically. Level switch for SK-197K1500-36 solar pump controller is optional, not mandatory
3.2 The Technical Parameters of The SK-197K1500-36 Solar Controller
Item
Technical Parameters
Voltage
Rate Voltage
36 VDC
Max Open Voltage
80 VDC
Under Protection Voltage
17 VDC
Over Protection Voltage
68VDC
Current
Rate Current
12 A
Over Protection Current
15 A
Peak Protection Current
18 A
MCU and Controller Mode
32bit MCU / FOC / Sine Wave Current / MPPT
Shell
Die-cast Aluminum (IP67)
Dimension
197mm*190mm*98mm
Weight
2.1kg
Cooling Mode
Natural Heat Dissipation
Operating temperature
-20
℃
- +50
℃
Storage conditions
-20
℃
- +80
℃
/5
~
85%RH(No condensation)
Operating mode
S1 (Continuous working)
Adaptive Solar
Panel
The Solar Panel of Vmp
17~18V
29~30V
35~36V
The Solar Panel of VOC
21~22V
35~37V
43~44V
*Nate: Please find the solar panel connection drawing at page 12 to 13