1
Troubleshooting:
1-
Please check to the 14. SAFETY VOLT parameter if correct.
2-
Please check to the safety voltage between 120 and 11A lines.
---------------------------------------------------------------------------------------------------------------------------------------------
2
Troubleshooting:
1-
Please check to the KG signal connection .
2-
You should seed 24V in KG signal when all conductors are fine.
---------------------------------------------------------------------------------------------------------------------------------------------
3
Troubleshooting:
1-
Please check to the T2 signal connection .
2-
If signal already have 24V in the T2 input you should change the input from the 32.AUX INPUT
parameter .
---------------------------------------------------------------------------------------------------------------------------------------------
4
Troubleshooting:
1-
SL1 and SL2 inputs cables .
2-
The 5.SHAFT COM. TYPE parameter must be seted to PAR. DATA in Parallel lift systems.
---------------------------------------------------------------------------------------------------------------------------------------------
5
Troubleshooting:
1-
R PHASE MISS / S PHASE MISS / T PHASE MISS , Please check to the missed phase voltage.
---------------------------------------------------------------------------------------------------------------------------------------------
Содержание Sky 301-VS
Страница 1: ...MAIN CONTROL BOARD Troubleshooting V 5 01 ...
Страница 4: ......