4.5  Slide the hex nut over the copper tubing end. Slide the brass ferrule over the 
tubing. Push the end of the tubing into the threaded fitting and slide the hex nut 
up to the fitting. Tighten the nut.  
4.6  Slide the bushing over the tubing, Insert the bushing through the humidifier 
wall until it snaps into place.  
4.7  Open  the  needle valve  at the  cold  water  pipe. 

IMPORTANT: 

Check  all fit-

tings for leaks.  

MOUNTING THE HUMIDISTAT:  

5.0  

NOTE: 

See the installation instructions packaged with the enclosed humidi-

stat (humidity controller). 

 

5.1  

NOTE: 

When wiring the unit to a system that has a multi-speed blower mo-

tor, or that uses a motor other than 120 VAC, include the Skuttle A50 Interface 
Relay in your installation. 

 

 

 

 

 

 

 

 

 

 

 

 

HUMIDIFIER CHECKOUT:  

Check the humidifier operation by following these procedures: 

6.0  Turn on the water valve to the humidifier. 
6.1  Turn the humidistat to the “ON” position.  
6.2    Set  the  furnace  thermostat  high  enough  to  allow  the  furnace  to  come  on. 
When  the  furnace  blower  comes  on,  the  humidifier  should  start  spraying 
(provided there is enough heat reaching the humidifier thermostat).  
6.3  Check the humidifier operation by turning the humidistat off, making sure the 
humidifier stops spraying. 

NOTE: 

If the humidifier continues spraying, there may 

be an error in wiring. Review the wiring diagram, above. 

 

6.4  Set the furnace thermostat low enough to allow the furnace to shut off. The 
humidifier should stop spraying either before or as the furnace blower shuts off. 

NOTE: 

Again, if the humidifier continues spraying, there may be an error in writ-

ing. Consult the wiring diagram. 

 

6.5  If the humidifier shuts off correctly, repeat steps 6.2 through 6.4 at least five 
times. Each time, check to see that no water impinges on ductwork or any part of 
the  heating  system. 

NOTE: 

If  water  impingement  or  fallout  could  occur,  YOU 

MUST  INSTALL  A  SUITABLE  DRAIN  PAN,  PLUMBED WITH  AN  ADEQUATE 
RUNOFF DRAIN.  

6.6  Set the thermostat to the desired setting.  
6.7  Finally, set the humidistat as recommended in Table 1, on the front of these 
instructions.  

HUMIDIFIER PARTS:  

7.0  Parts may  be  ordered  through your local  heating or  plumbing  dealer.  (See 
Figure 6, below).  
7.1  When ordering repair parts, always give the following information:  

Model Number 
Serial Number (if possible)  
Part Number (See Table 3, right, top.)  
Part Name 

 

 

 

PARTS LIST 

 

HOMEOWNER HUMIDIFIER TIPS:  

8.0  If the mineral content of the water in your home is above normal, a lime dust 
may form in the duct distribution system, as well as in your living areas.  
8.1  In a home that has had little or no humidification, a new humidifier may op-
erate almost continuously to attain the desired level of relative humidity. This is 
because furniture, woodwork carpeting, plaster and houseplants will absorb the 
newly-produced humidity to reach normal moisture levels. This period of adjust-
ment will take approximately three weeks.  
8.2  Natural drafts in the home can cause humidified air to escape through open 
fireplace dampers. Make sure they are closed when not in use.  
8.3    When  the  weather  turns  warmer,  humidification  is  unnecessary. 

IMPOR-

TANT

: Turn  the water  and  electrical  power to your  humidifier ‘OFF”  after 

each heating season.  

8.4  When water frequently flows through your humidifier, the nozzle and/or sole-
noid valve can become clogged by lime and other mineral deposits, thereby di-
minishing humidification effectiveness. When this occurs, you should replace the 
affected part(s). In fact, it’s a good idea to replace the spray nozzle at the start of 
each  heating  season  to  help  ensure  continuous,  trouble-free  operation  of  your 
humidifier.  (You may  wish  to  have your  heating  or  plumbing contractor  perform 
this service for you.)  
8.5    The  inline  water  filter  should  be  cleaned  at  the  end  or  beginning  of  each 
heating season. To do so, loosen the hex nut (see Figure 4, left, top), slide the 
tubing out of the tube connector and remove the filter. At this time, the solenoid 
valve may be disassembled for cleaning.  
8.6  

IMPORTANT: 

For parts and service, contact your local authorized dealer. 

 

CAUTION: 

If  excessive  moisture  appears  on  windows  or  walls,  reduce  the    

humidity  setting  on  your  humidistat  enough  to  eliminate  condensation.  If  the 
situation continues, turn off the water valve that permits water flow to the humidi-
fier, and contact your heating or plumbing contractor.  

Key No. 

Part No. 

Description 

Qty. 

000-1715-013 

Mounting Panel 

A00-0641-099 

Front Panel Assembly 

000-0431-019 

Thermostat 

A00-1319-034 

Drain Basin Assembly 

000-0814-070 

Indicator Light, 24-Volt 

000-1106-018 

(Part no. varies w/size) 

.50 Gal. Nozzle 

(Consult whlslr. for available sizes) 

000-1319-055 

Nozzle Body 

000-1319-054 

45° Street Elbow 

A01-0814-148 

Solenoid Valve, 24-Volt 

(includes Key Nos. 10 & 12) 

10 

000-1319-070 

90° Street Elbow 

11 

000-1154-000 

Tubing Connector 

12 

000-1319-051 

Inline Filter 

13 

A00-1128-005 

Self-Piercing Valve 

14 

SK0-0055-001 

Humidistat 24-Volt Wall or Duct 

Mounting 

Table 3

 

NOTES 

Wiring Diagram / Figure 5

 

Figure 4

 

Figure 6

 

Отзывы: