![Skutt EnviroVent 2 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/skutt/envirovent-2/envirovent-2_operating-manual_1289552012.webp)
12
O
PERATION
O
PERATION
Loading the Kiln
The bottom kiln shelf needs to be supported at least one inch off the kiln fl oor to allow suffi cient
air circulation. If the holes are blocked, venting cannot take place. If you are using half shelves a slight
gap left between them will allow better air circulation in the kiln chamber. If you are loading ware near
the lid be sure not to place it directly under a vent hole. This may cause discoloration in glazes or ther-
mal shocking.
Be sure to close the lid and plug all of the peep holes. You can open any peephole during the fi ring to
check the bending of witness cones and the progress of your fi ring. Do not prop the lid or leave any
peepholes open during a normal fi ring. To do so can cause fumes to enter the room and additional room
temperature air drawn into the kiln may affect the fi ring.
Important: Keep the kiln fl oor clean and the holes unobstructed for the EnviroVent 2 to
continue doing its job properly.
Motor Operation
The EnviroVent 2 motor is equipped with an in-line toggle switch in the power cord. This switch
must be turned ON in order to ventilate your kiln and collect the fumes.
Leaving the motor in the on position during cooling will reduce the amount of time it takes to cool the
kiln to a temperature where you can safely handle your ware. Turning the motor off will not signifi cant-
ly affect the kilns ability to maintain temperature or perform a slow cooling therefore it is not necessary.
If you would like to be able to automatically control when the Envirovent 2 turns on and off, you can in-
stall an EnviroLink on KilnMaster and GlassMaster Kilns. See the Accessories section for more details.
Fresh Make-up Air
It is essential to have a source of fresh air to replace the air vented outdoors. The EnviroVent 2
fan moves 140 cubic feet per minute. Unless you know that the room ventilation can handle the total
volume of loss, leave a window or door slightly ajar for make-up air. Remember: do not exhaust fumes
near a fresh air intake.
Firing times
When the correct holes are drilled in your kiln, fi ring times should not be much longer than nor-
mal. If fi ring times are signifi cantly longer, see the Troubleshooting section for help.
Содержание EnviroVent 2
Страница 16: ......