![sks 300013 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/sks/300013/300013_installation-instructions-manual_1289433013.webp)
13
Support Hotline: +49 (0) 2661 98088-112
Support E-Mail: [email protected]
Version No. 1-0
Document No. 97021800
SKS-Kinkel Elektronik GmbH
300013 Dome camera
EN
3 Terminal Designation
Terminals sleeve plug
Description
-
GND
+
Video output
Terminals BNC plug
Description
AV-
GND
AV+
+12 V
2.9
Safety
Electrical shock hazard to persons. Danger of burns, damage to device and malfunctions.
VDE 0100 and VDE 0800 guidelines must be complied during installation. (Germany)
Counter measures:
3
Before beginning any work, deactivate and disconnect all energized electrical wires.
3
Secure the switched off/disconnected lines against erroneous reconnection.
3
Use a measuring device to make sure that the wires are de-energized.
3
Cover up any adjacent, energized or conducting components.
3
All work and all electrical connections must comply with the national provisions for the country in question and
must be performed by appropriately trained personnel.
Mounting, installation, reparation and initial setup must be carried out by qualified elec
-
tricians only! When working on systems with 230 V alternating voltage the safety require-
ments of DIN VDE 0100 must be complied with.
The SKS planning guide (can be downloaded from www.sks-kinkel.de) must be followed during installation!
4 Technical Data
Camera
Image sensor
1/2.7” CMOS
Effective pixels
1920 (H) × 1080 (V), 2MP
Scanning System
Progressive
Electronic Shutter Speed
PAL: 1/25~1/100000s
NTSC: 1/30~1/100000s
Minimum Illumination
0.04 Lux/F1.85, 30 IRE, 0 Lux IR on
S/N Ratio
More than 65 dB
IR Distance
Up to 30 m
IR On/Off Control
Auto/Manual
IR LEDs
2
Lens
Lens Type
Vari-focal lens/Fixed iris
Mount Type
Board-in
Focal Length
2.7-12mm
Max Aperture
F1.8
Angle of View
H: 106°~33°
V: 56°~19°
Focus Control
Manual
Close Focus Distance
500 mm/19.7“