5.  Setting Up Internal Calling 
 

5.1

 

Programming Internal Call Addresses 

 

Internal calling makes it possible to communicate between two  intercom units.  Using the HT4600, you 
can speak with up to 6 intercom units. Buttons 1 through 6 are provided on the HT4600 for this purpose. 
You place an internal call by pressing the matching button.  

 

Intercom Unit 

Intercom Unit(s) 

 
 

Programming Procedure for Internal Addresses: 
 

Note: 

Before  the  internal  call  addresses  can  be  programmed,  the  house  call  address  must  be 
programmed as described in 4.2. 

 

Step 

Description 

Set the internal call address (target address) on the DIP-Switch. 

Push the programming button the desired internal call button within 2 seconds. 
Push this combination for around 5 seconds until you hear the second signal 
tone.  

 
 
 

5.2 Deleting Internal Call Addresses 
 

No individual internal call addresses can be deleted. When you delete, all internal call addresses stored 
will always be deleted.   
Hold  the  programming  button  down  and  push  the  corresponding  internal  call  button  within  2  seconds. 
Deletion is completed when you hear a high-pitched tone lasting 3 seconds. Release the buttons. All call 
addresses are now deleted.  

 

Содержание HT 4600

Страница 1: ... 1 HT 4600 Version 1 1 ...

Страница 2: ... irrtümliches Wiedereinschalten Stellen Sie Spannungsfreiheit durch Messung fest Decken Sie benachbarte unter Spannung stehende oder leitfähige Teile ab Alle Arbeiten und elektrische Anschlüsse müssen den nationalen Bestimmungen des jeweiligen Landes entsprechen und von entsprechend ausgebildetem Fachpersonal durchgeführt werden Bei Geräten mit 230 V Anschluss ist die DIN VDE 0100 zu beachten und ...

Страница 3: ... eindrücken und die Front abnehmen Aufputz Montage Mit Dübel und Schrauben das Hinterteil der Sprech stelle an der Wand befestigen Dabei auf das Kabel achten Unterputz Montage Mit zwei Schrauben das Hinterteil der Sprechstelle an der Unterputzdose befestigen Dabei auf das Kabel achten ...

Страница 4: ...er Türstation zugeordnet Die Adressen sind im Anhang aufgeführt In der Regel wird mit der SKS BUS Rufadresse A1 begonnen Beim Austausch von Sprechstellen stellen Sie den DIP Schalter so ein wie bei der zuvor montierten Sprechstelle Das Frontteil auf das Hinterteil drücken bis die Klipps einrasten Achten Sie dabei darauf dass keine blanken Adern die Leiterplatte von hinten berühren können ...

Страница 5: ...lingeltaste an der Türstation 2 Die Programmiertaste für ca 5 Sekunden drücken bis der erste Kontrollton ertönt 3 Nach diesem Kontrollton ertönt ein kurzer Ton Er signalisiert dass die erste Rufadresse programmiert ist Die Anzahl der kurzen Töne signalisieren auf welchem Speicherplatz die Rufadresse gespeichert wurde 4 Zum Programmieren weiterer Rufadressen wieder holen Sie die Schritte 1 bis 3 Es...

Страница 6: ...rt sein Arbeitsschritt Beschreibung 1 Die Internrufadresse Zieladresse am DIP Schalter einstellen 2 Halten Sie die Programmiertaste gedrückt und drücken Sie innerhalb von 2 Sekunden die gewünschte Internsprechtaste für die gewünschte Innensprechstelle Halten Sie die Tastenkombination für ca 5 Sekunden gedrückt bis Sie den zweiten SIgnalton hören 5 2 Löschen von Internrufadressen Es können keine ei...

Страница 7: ...odie Wird die gewünschte Melodie abgespielt lassen Sie beide Tasten los Es stehen 8 verschiedene Kingeltöne zur Auswahl Etagenrufklingelton ändern Die Tontaste gedrückt halten und anschließend die Türöffnertaste innerhalb von 2 Sekunden drücken und beide gedrückt halten Warten Sie bis die gewünschte Melodie ertönt Lassen Sie beide Tasten los Es stehen 4 verschiedene Etagenruftöne zur Auswahl Kling...

Страница 8: ...che Daten Elektrische Daten Spannung a b 19 23VDC Allgemeines Umgebungstemperatur 10 C bis 45 C Feuchtigkeit 20 bis 90 nicht kondensierend Gehäuse Kunststoffgehäuse Abmessungen Breite x Höhe x Tiefe 82 x 193 x 33mm ...

Страница 9: ... 9 ...

Страница 10: ...reneous reconnection Use a measuring device to make sure that the wires are deenergized Cover up any adjacent energized or conducting components All work and all electrical connections must comply with the national provisions for the country in question and must be performed by appropriately trained personnel DIN VDE 0100 must be observed and complied with in devices with a 230V connection 2 Termi...

Страница 11: ...r middle clip and remove the front Assembly of Mounting Box Fasten the rear part of the intercom unit to the wall using dowels and screws Watch the cable Flush Mounting Socket Assembly Using two screws fasten the rear part of the intercom to the flush mounting socket Watch the cable ...

Страница 12: ...utton at the door station The addresses are listed in the appendix As a rule the SKS BUS call address set in with A1 When replacing intercom units set the DIP Switch as it is for the previously mounted intercom unit Press the front part down onto the rear part until the clips snap into place Make sure that no exposed wires can touch the printed circuit board from behind ...

Страница 13: ...tation 2 Push the programming button for about 5 seconds until you hear the control tone 3 After this control tone sounds you will hear a short tone that signals that the first call address has been programmed The number of short tones indicates the memory location at which the call address was stored 4 To program additional call addresses repeat steps 1 to 3 A maximum of 4 call addresses can be s...

Страница 14: ...e house call address must be programmed as described in 4 2 Step Description 1 Set the internal call address target address on the DIP Switch 2 Push the programming button the desired internal call button within 2 seconds Push this combination for around 5 seconds until you hear the second signal tone 5 2 Deleting Internal Call Addresses No individual internal call addresses can be deleted When yo...

Страница 15: ... buttons 8 different buttons are available Change floor call tune Push the sound button and then quickly press the open door button within 2 seconds A different tune will sound with each push of the button Wait until the desired tune plays then release both buttons There are 4 different floor call tunes Change ring volume Push the sound button until the desired volume is reached There are five dif...

Страница 16: ...16 7 Technical Data Electric Data Voltage a b 19 23VDC General Ambient Temperature 10 C to 45 C Humidity 20 to 90 non condensing Housing Plastic housing Dimensions width x height x depth 82 x 193 x 33mm ...

Страница 17: ... 17 ...

Страница 18: ...êcher toute remise sous tension accidentelle Constatez l absence de tension en procédant à une mesure Recouvrez les éléments voisins sous tension ou conducteurs Tous les travaux et les connexions électriques doivent répondre aux dispositions nationales du pays concerné et sont l affaire de spécialistes dûment qualifiés La norme DIN VDE 0100 est à observer et à respecter pour les appareils connecté...

Страница 19: ...ip inférieur à l aide d un tournevis et démonter la façade Montage apparent Fixer au mur la partie arrière du poste avec des vis et des chevilles Attention au câble Montage encastré Fixer la partie arrière avec deux vis sur la boîte d encastrement Attention au câble ...

Страница 20: ...rie sur la station de porte Les adresses figurent en annexe En règle générale on commence par l adresse d appel du bus SKS A1 Lorsque vous remplacez les postes réglez le microinterrupteur DIP comme sur le poste préalablement monté Appuyez la façade sur la partie arrière jusqu à encliquement des clips Veillez à ce qu aucun fil nu ne puisse entrer en contact à l arrière du circuit imprimé ...

Страница 21: ...on 5 secondes sur le bouton de programmation jusqu à ce que la tonalité de contrôle retentisse 3 Après cette tonalité de contrôle une brève tonalité signale que la première adresse d appel est programmée Le nombre de brèves tonalités signale sur quel emplacement de mémoire l adresse d appel a été enregistrée 4 Répétez les étapes de 1 à 3 pour programmer d autres adresses d appel Au maximum il est ...

Страница 22: ...adresse d appel interne adresse de destination sur l interrupteur DIP 2 Maintenez la touche conversation enfoncée et appuyez la touche de conversation interne voulue dans un délai de 2 secondes pour le poste interne voulu Maintenez la combinaison de touches appuyée pendant environ 5 secondes jusqu à ce que vous entendiez la deuxième tonalité de signalisation 5 2 Suppression des adresses d appel in...

Страница 23: ...de touche Une fois la mélodie souhaitée exécutée relâchez les deux touches On peut choisir entre 8 tonalités de sonneries Changer la tonalité d appel à l étage Maintenez appuyée la touche son puis pressez brièvement pendant 2 secondes la gâche d ouverture de porte et maintenez les toutes deux enfoncées Attendez jusqu à ce que la mélodie souhaitée retentisse Relâchez les deux touches On peut choisi...

Страница 24: ...echniques Caractéristiques électriques Tension a b 19 23VDC Généralités Température ambiante de 10 C à 45 C Humidité 20 à 90 sans condensation Boîtier Boîtier plastique Dimensions largeur x hauteur x profondeur 82 x 193 x 33mm ...

Страница 25: ... 25 ...

Страница 26: ... 26 Anhang Appendix Annexe DIP Switch settings for intercoms switch actuator and TK Adapter Standard address range Extended address range ...