32
Technical User Guide
Grow-Box
4
Installation guide
4.1
Electrical connection
Installation, servicing and troubleshooting of all electrical equipment must be carried out by
qualified personnel in compliance with the applicable national regulations, - in Europe according
to EN 60204-1 and any other EU regulations.
The installation of a power supply isolator is required for each motor and power supply to
facilitate voltage-free work on the electrical equipment. SKOV A/S does not supply the power
supply isolator.
4.1.1
Cable plan
4.1.2
Connection of DOL 114 temperature/humidity sensor
Conductor color in cable for sensor
Signal type
Conductor no. in cable for controller
Brown
+24 V DC
1
Blue
0 V
2
Black
(Temperature) 0-10 V
3
White
(Humidity) 0-10 V
4
The text on the cable markings matches the text on the
corresponding connection boxes.