8
Technical User Guide
DOL 530/DOL 630 Extension Box
3.2
Extension box with one I/O module (136470)
1)
Connect flat cable plug from
I/O module 1
in house controller to
I/O module 2
in the extension
box
(A)
.
2)
Set jumper OFF/ON
(C)
on the
I/O module 1
of the house controller to OFF.
3)
Set jumper OFF/ON
(D)
on the
I/O module 2
of the extension box to ON.
4)
Set the I/O-modules address switch (Rotary Switch) as follows:
I/O module 1
Address =
1
I/O module 2
Address =
2
5)
Connect the earthing contact of the extension box
(F)
to the earthing contact of the house controller
(G)
.
6)
Run the earth cable through the lower rubber sleeve
(H)
.
7)
Set CAN protocol jumper
(I)
according to the setting on the main module. If jumper does not exist
on the main module, set CAN protocol jumper on the I/O module to Classic.