4.4 Cooling pump for several house sections
A joint cooling pump can be controlled by the individual climate controllers in one or more house sections.
Cooling starts when this is required by a climate controller in one of the house sections.
Procedure:
1. Mount additional supplementary relay in the climate controllers.
2. Connect the climate controllers, solenoid valves and cooling pump.
3. Setup/set the climate controllers.
Mounting of additional supplementary relay in the climate controller
1. Disconnect the power supply to the climate controller and cooling pump.
2. Place a two-pole supplementary relay or an ordinary contactor in each of the climate controllers that are to
control the common cooling pump. Place the contactor on a DIN rail.
3. The supplementary relays activate:
• The cooling pump - if just one of the climate controllers requires cooling.
• The solenoid valve of the individual house section (opens for high-pressure cooling).
Setup, setting and testing of the climate controller
See
Technical Manual
for the climate controller in question.
Содержание DA 2000
Страница 2: ......
Страница 17: ...DA 2000 Technical User Guide 17 4 2 Pump without frequency converter 4 2 1 Circuit diagram 1 x 230 V 230 V...
Страница 19: ...DA 2000 Technical User Guide 19 4 2 2 Circuit diagram 3 x 400 V 230 V...
Страница 21: ...DA 2000 Technical User Guide 21 4 2 3 Circuit diagram 3 x 220 V 3 x 230 V 230 V...
Страница 22: ...DA 2000 22 Technical User Guide 437153 7832 14 2 2 kW 9 4 A 437156 7833 14 60 3 kW 11 1 A...
Страница 23: ...DA 2000 Technical User Guide 23 4 3 Pump with frequency converter 4 3 1 Circuit diagram 3 x 230 V 230 V...
Страница 24: ...DA 2000 24 Technical User Guide 437162 7865 14 4 kW 15 1 A...
Страница 25: ...DA 2000 Technical User Guide 25 4 3 2 Circuit diagram 3 x 400 V 230 V...
Страница 28: ...DA 2000 28 Technical User Guide 230 V House section 1 House section 2 House section 3...
Страница 35: ...DA 2000 Technical User Guide 35 8 1 1 Dimensioned sketch...
Страница 37: ...DA 2000 Technical User Guide 37 8 2 1 Dimensioned sketch...
Страница 38: ......
Страница 39: ......