20
Installation
Installation Manual
SKOPE MISA Cool & Freezer Rooms
Freeblock Refrigeration Unit
Introduction
The SKOPE MISA Freeblock side mount is a wall mounted refrigeration unit
which is easily positioned and locked onto the side of the room using the
supplied cam lock tool. The standard opening size for the refrigeration unit
is 800mm wide x 400mm high.
The following information applies to SKOPE MISA Freeblock side mount
refrigeration units. For information on SKOPE MISA Drop-In refrigeration
unit installation refer to “Drop-In Refrigeration Unit” on page 31.
If the room is supplied with a third party drop-in unit or remote refrigeration
system, ceiling or wall panels will need to be cut to fit the refrigeration unit.
If it is necessary to cut into the panels, ensure measurements are correct
before cutting and take care when cutting as the panels are delicate. Do
not
cut through cam locks. Ensure that the ceiling panels have adequate
support for the refrigeration unit. If more ceiling support is required, hangers
on wires attached to the cool room roof can be used. The wires can be
attached to either the building internal roof beam/s. Or alternatively a
strengthening beam or plate can be installed across the top of the room to
support the refrigeration unit.
Refer to the documentation provided with the drop-in or remote refrigeration
unit for further information.
Safety and
Service
Guidelines
When installing, using, maintaining and servicing the Freeblock refrigeration
unit, follow the safety and service guidelines below:
Installation must be carried out in strict compliance with the diagrams
and instructions supplied by the manufacturer.
Electrical connections must meet all relevant safety standards.
Use safety gloves to protect your hands from cuts.
The unit is not suitable for use in explosive environments, therefore the
use of the unit in an explosion dangerous atmosphere is absolutely
forbidden.
The unit is not suitable for use in corrosive environments. In such cases
protect the condenser coil and evaporator coil with appropriate means.
Servicing must be completed by trained personnel or manufacturer
according to the provisions supplied by EN378.
When maintenance or servicing involves operations on the refrigeration
circuit, empty the system and allow it to reach atmospheric pressure.
Do not discharge the refrigerant gas into the atmosphere. Refrigerant
gas must always be recovered by specialised technicians using suitable
equipment.
Quantity and quality of the refrigerant charge are indicated on the data
plate.
Do not use alternative refrigerants (especially inflammable fluids e.g.
hydrocarbons) or air.
Do not modify or alter the refrigerating circuit or its components.
The unit shall only be used following the instructions indicated by the
supplier. Any incorrect use can result in damage to the unit and
represents a serious danger for peoples health.
IMPORTANT
The refrigeration unit is heavy and requires two or more people
to lift.