Servicing
Cleaning
Cabinet
When necessary, wipe both the interior and exterior of the cabinet with a
damp cloth. Ensure the cabinet is disconnected from the mains power
supply before cleaning the cabinet.
Condenser
Coil
Integral cabinets only. The condenser coil should be brushed clean once a
month and blown clean by qualified service personnel every six months.
Over time, dust may accumulate within the condenser that cannot be
removed with a brush. If this occurs, contact SKOPE to arrange for a
SKOPE authorised service agent to clean the condenser with compressed
air. The condenser coil is located inside the refrigeration unit compartment
and is accessed by opening the unit front cover. Disconnect the cabinet from
the power supply before cleaning the condenser coil.
CAUTION
Disconnect the cabinet from the mains power supply before
cleaning the condenser coil or washing the cabinet with water.
IMPORTANT
If the electronic controller display flashes ‘
cht
’ the condenser
coil must be cleaned immediately.