SKOPE B550/660-2 and BME550-2
Installation
User Manual
Positioning the Cabinet
Location
When positioning the cabinet, avoid direct sunlight and warm draughts etc.
The cabinet must NOT be situated where it is affected by hot air from
adjacent equipment, as this will compromise the airflow and performance of
the chiller.
Ventilation
For efficient operation of the chiller, it is essential that adequate ventilation
be provided around the refrigeration unit. The maximum recommended
ambient temperature (at place of installation) is 40°C, although the chiller
will generally use less power when installed in a cooler location.
Installation
Guidelines
When installing the chiller:
Ensure the cabinet is positioned on a level surface so the door shuts
and seals correctly and to prevent the condensate tray from
overflowing.
Allow adequate space for door opening. The self-closing door has an
internal torsion bar which is pretensioned at the factory.
Do not overload the power supply (see the rating label inside the
cabinet for power supply and current draw)
Power Cord
The chiller is supplied with a 3.0m flexible power cord fitted with a 3-pin plug.
For transit purposes the power cord is clipped to the roof of the cabinet (see
Figure 1 below). For convenience, the cord should be retrieved before the
machine is positioned, when walls and partitions may make access difficult.
Warning:
For efficient operation of the chiller it is essential that adequate
ventilation be provided around the refrigeration unit.
Power Cord
Clip
Cabinet Roof Top
Figure 1: Flex and
Plug