![Skope ActiveCore SKT series Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/skope/activecore-skt-series/activecore-skt-series_user-manual_1289181003.webp)
Door Lock/s
The chiller may be fitted with bracket locks or key locks, located above or below each door. Bracket locks require a lock
(padlock or similar) through the brackets to lock the door. Key locks can be locked with the supplied key.
Electronic Controller
The electronic controller regulates the chiller’s temperature, signals alarms and captures operational
information. The chiller temperature is factory set for storage of perishable product (all shelves maintain
temperatures below 5°C).
To customise the chiller settings to your requirements and view historical data, download the
SKOPE-connect app from the Google Play Store or Apple App Store, and connect via Bluetooth
®
.
Lights
The chiller lights switch on and off automatically depending on chiller usage.
Cleaning
Ensure the chiller is unplugged from the power supply before cleaning.
Wipe the inside and outside of the cabinet with a damp cloth, taking care to keep moisture away from electrical parts.
The condenser coil must be kept clean. SKOPE strongly urges monthly cleaning of the condenser coil and air filter (optional
air filter available on BME only). Do
NOT
use hard or sharp tools to clean the coil as these may cause damage.
TME and SKT - Clean Coil
BME and SKB - Clean Filter
1.
Unplug the chiller from the power
supply.
1.
Rotate the grille at the bottom of the
front kick panel out to gain access to
the filter.
2.
Remove the front panel from the top
of the cabinet. Lit sign panels also
need to be unplugged.
2.
To remove the filter, use the finger
loops to pull the filter up and detach
from the front kick panel.
3.
Brush the condenser coil with a soft
brush to remove any dust and fluff.
3.
Clean the filter with a vacuum
cleaner, wash with cold water and
shake excess water off before refit-
ting. Do not apply hot water, blow
dry or place in dishwasher. If neces-
sary, discard and refit new air filter.
4.
To refit the filter, insert it up into the
front kick panel vent with the finger
loops facing out. Then clip the into
the slots on the bottom face of the
front kick panel vent.
4.
Refit the sign assembly and
reconnect to the power supply.
Important
When refitting, ensure the tabs on
the back of the sign are located in
the notches on top of the cabinet,
and that the sign is pushed fully in
and secure.
BME and SKB - Clean Coil
1.
Unplug the chiller from the power
supply.
2.
Remove the front kick panel from the
front of the cabinet.
3.
Brush the condenser coil with a soft
brush to remove any dust and fluff.
4.
Refit the front panel and reconnect
to the power supply.
Grille
Grille
Finger loop
Coil
Tab and notch
Coil
Refrigeration