SkoFlo Industries BPR15000MFC-MA Скачать руководство пользователя страница 3

Surface Back Pressure Regulator

 

 

 

 

 

BPR15000MFC-MA

 

 

Operations and Maintenance Instructions

 

 

 

 

 

 

 

 

 

 

2

 

A

BOUT 

S

KO

F

LO

 

Our experience and track record speak for themselves. 
SkoFlo has delivered over 20,000 valves since 1988. We are 
the only company that proves our products by testing in 
surface applications before deploying them subsea. The 
result is that SkoFlo valves have amassed over 25 million 
continuous operating hours. This level of experience is 
unparalleled and provides the basis for being the solution 
provider to our served market. 

SkoFlo Surface Back Pressure Regulator (BPR) is the 
industry leader in the oil and gas marketplace and 
regulating pump discharge pressure in chemical injection 
systems.  

G

ENERAL 

I

NFORMATION

 

1.

 

Product Overview 

The BPR is designed to maintain a constant set pressure in 
pump discharge lines feeding the chemical injection 
system. As pressure rises in the pump discharge line, the 
BPR will maintain pressure levels at a Set Point while 
allowing the unused fluid to return to the chemical 
holding tank.  
BPRs should be used in any pump discharge line where 
the pressure must remain at a constant level and unused 
fluid can be routed back to the fluid holding tank.  

BPRs are not designed to be used as Pressure Safety 
Devices.  

BPRs provide a constant pressure to the system with 
continuous spill-off to the chemical tank that is 
independent of the flow rate. The BPR15000MFC series 
has a maximum operating pressure of 15,000psi and 
supports a flow range of 0.5 – 15 GPM. 

2.

 

Guidelines for Using this Manual 

The following instructions are provided to ensure a safe 
and proper installation. 

 

Read all instructions prior to installation and operation 
of this product. 

 

Follow all warning and caution notes. 

 

Install this product as specified in the instructions 
provided by SkoFlo. 

 

Prior to use, educate personnel in the proper 
installation, operation, and maintenance of this 
product. 

 

Only use replacement parts specified by SkoFlo. 

3.

 

Warning, Caution, Notice 

Throughout this manual there are steps and procedures 
which, if not followed, may result in a hazard. The 
following flags are used to identify the level of potential 
hazard. 

 

 

 

! WARNING

 

 

WARNING IS USED TO INDICATE THE PRESENCE OF A 
HAZARD WHICH CAN CAUSE SEVERE INJURY, DEATH, OR 
SUBSTANTIAL PROPERTY DAMAGE IF THE WARNING IS 
IGNORED. 

 

 

 

! CAUTION

 

 

CAUTION IS USED TO INDICATE THE PRESENCE OF A 
HAZARD WHICH CAN CAUSE INJURY OR PROPERTY 
DAMAGE IF THE WARNING IS IGNORED.

 

 

 

 

! NOTICE

 

 

NOTICE IS USED TO NOTIFY PEOPLE OF INSTALLATION, 
OPERATION, OR MAINTENANCE INFORMATION, 
WHICH IS IMPORTANT BUT NOT HAZARD RELATED.

 

 

4.

 

Abbreviations and Acronyms 

BPR  Back Pressure Regulator 

BOM  Bill of Materials 

GA 

General Arrangement 

MA 

Manual 

NPT  National Pipe Thread 
PPE  Personal Protective Equipment 

PSI 

Pounds per Square Inch 

 

 

 

 

Содержание BPR15000MFC-MA

Страница 1: ...Pioneering an Industry Surface Back Pressure Regulator Medium Flow Manual Operation Operations and Maintenance Manual Industries DOC 03704 Rev B BPR15000MFC MA...

Страница 2: ...Warning Caution Notice 2 4 Abbreviations and Acronyms 2 Installation Maintenance 3 5 Installation Procedures 3 6 Start up Procedures 3 7 Operation Notes and Warnings 3 8 Maintenance Notes 4 9 Storage...

Страница 3: ...re to the system with continuous spill off to the chemical tank that is independent of the flow rate The BPR15000MFC series has a maximum operating pressure of 15 000psi and supports a flow range of 0...

Страница 4: ...ngs The SkoFlo Back Pressure Regulator has hard seats and is not designed to provide complete bubble tight shut off If tight shutoff is required separate isolation valves should be used for shutting o...

Страница 5: ...lubricated with Parker Super Lube or equivalent Install backup ring on low pressure side of O ring For more details see seal kits sheets 2 in Appendix C D or E Make sure the backup ring is lined up a...

Страница 6: ...SurfaceBack Pressure Regulator BPR15000MFC MA Operations and Maintenance Instructions 5 10 Trouble Shooting Improper Valve Performance...

Страница 7: ...Surface Back Pressure Regulator BPR15000MFC MA Operations and Maintenance Instructions 6 APPENDIX A GENERAL ARRANGEMENT BILL OF MATERIALS BOM...

Страница 8: ...Surface Back Pressure Regulator BPR15000MFC MA Operations and Maintenance Instructions 7...

Страница 9: ...Surface Back Pressure Regulator BPR15000MFC MA Operations and Maintenance Instructions 8...

Страница 10: ...Surface Back Pressure Regulator BPR15000MFC MA Operations and Maintenance Instructions 9...

Страница 11: ...Surface Back Pressure Regulator BPR15000MFC MA Operations and Maintenance Instructions 10...

Страница 12: ...Surface Back Pressure Regulator BPR15000MFC MA Operations and Maintenance Instructions 11 APPENDIX B BOM PRIMARY STAGE...

Страница 13: ...Surface Back Pressure Regulator BPR15000MFC MA Operations and Maintenance Instructions 12 APPENDIX C BOM PRESSURE STAGE...

Страница 14: ...Surface Back Pressure Regulator BPR15000MFC MA Operations and Maintenance Instructions 13 APPENDIX D BOM CHECK STAGE...

Страница 15: ...SkoFlo Industries 14241 NE 200th Street Woodinville WA 98072 USA Tel 1 425 485 7816 Fax 1 425 368 1696 www skoflo com DOC 03704 Rev B...

Отзывы: