Edition: 2021-01-29
ETNSTCI/ETNSTCILF Installation Manual
Page 10 of 14
Date
F
1
Designed by
E
D
Approved by - date
4
Edition date
Checked by
F
Sheet
Scale
E
D
C
B
A
1
Revision note
RevNo
C
B
2
3
4
Signature
Date
A
Checked
Revision
2011.10.27
A.Matre
SKIPPER Electronics AS
DI-ETNSTCI
PC - 2011.11.04
Doc. Instr. for Ice Tank ETNSTCI
Ø 219*
35
298,5
268,5
210
Assembled
Factory Assembled (in MT-C001)
* NOTE: DUE TO SURFACE MACHINING, THE DIAMETER MAY VARY
BETWEEN 217 AND 219MM
Parts under Module ZZL-01011
Parts under Product ETNSTCI-M-KIT
Assembling order
* To be ordered separatly
Cable stuffing Tube to be welded
to end of Cable Pipe at a position
well above Load Water Line.
Steel Pipe, minimum 35mm inside.
Wall thickness on galvanized Pipe:
8mm, on black Pipe: 10mm.
Quality of material as stated in
D.N.V. Rules chap.X Para 7A, type III.
The Pipe to be welded and cooled off
before pulling the Cable.
After docking out it may be necessary to open Gable Gland to release air from Tank
NOTE !
DO NOT mount Cable Gland
inside Ice Tank
07
05
06
12
01
02
03
08
10
13
04
11
09
QTY.
1
1
ITEM
1
5
3
2
4
3
1
1
7
6
*8
9
1
2
1
1
10
6
ETN050BEL/(+X = 40m.)
TC-2008
TC-2003
SB-6029
TC-2013
TC-2002
DWG.NO.
TC-2006
Transducer Tank Combo
DESCRIPTION
Inner Mounting Ring for Icetank
Allen Screw M8x100 DIN912 A4
Washer M12 DIN125 A2
Transducer 50 kHz 25/40meter
Allen Screw M8x16 DIN912 A4
Tank Main Adapter Ice 50 Khz.
Bronze Nut, PG-Nipple
Tank, Ice Protection Plate
Rubber Gasket Ø23,5/12,5x15mm
12
11
Allen Screw M6x14 DIN912 A4
4
1
13
6
Cable Gland, Steel 6"
TC-2024
Tank Cartridges Ice Plate
TC-2007
00
01
ETN0200FS/(+X = 40m.)
Transducer 200 kHz 25/40meter
ZOA-01052
ZOA-01016
ZOA-01053
ZOA-01009
PART.NO.
ETNADC
ETNARCPL
ZOA-01008
ZOA-01017
ZOA-01021
ZOA-01051
6. 50 or 200 kHz Transducer in ice tank ETNSTCI TC-2002
Pos
Part number
Size
Torque
03
ZOA-01053
M8
25Nm
10
ZOA-01016
M8
20Nm
11
ZOA-01052
M6
10Nm
SKIPPER
Electronics AS