34
Opto outputs
Factory default value is NOT USED
VOID
Ref 6.5.25 for connections details
Analog outputs
Analog outputs can be configured to provide a
varying voltage output in response to a measured
value in the EMES60 system.
Touch the first box to switch between 0 to 10 V
voltage output and 4 to 20 mA current output.
The analog output can be one of:
•
DBT: depth below transducer
•
DBS: depth below surface
•
DBK: depth below keel
Touch the next box to enter the value that corresponds to the lowest analogue output.
For example, if ‘0.0’ is entered from the touch screen keyboard, then the lowest
analogue output (0V or 4mA) is given for depth of m.
Touch the next box for the highest value. For example, if ’100.0’ is entered, then the
highest analogue output value (10V or 20mA) corresponds to depth of 100 m or greater.
Ref 6.5.25 for connections details
Factory default value is NOT USED
Screen copy setup
Screen copy: this controls what happens when
the Print Screen button at the top of most
windows is touched
Touch Printer to send screen copy images to a
printer, and File to send them to a file, stored in
the HMI memory.
Touch this box to select the printer from a list of
available system printers.