![SKIPIO Dual Table Series Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/skipio/dual-table-series/dual-table-series_service-manual_1288580028.webp)
27
3-4-9. Control Eva fan motor
STEP
OPERATION
DISPLAY
RESULT
Step 1
Push the ▼ ▲ button Five seconds.
Step 2
Push the ▼button ninetime.
Now is the setting value.
Step 3
Push the ▼ button When changed
Setting value Reference Table 7
Table 7
Setting value
description
Memo
“o”
Eva motor is running with setting mode on Comp Off
“n”
Eva motor is keeping running even if Comp Off
3-4-10.Verify Error Code
STEP
OPERATION
DISPLAY
RESULT
Step 1
Push the ▼ ▲ button Five seconds.
Step 2
Push the ▼button fourtime.
If Bar LED will not display error,
it will indicate no
Step 3
Push the ▼ button When changed
Error value
If there are lots of error, bar
LED will display error sequently.
☞Verify Error Code
No
Function
Display
Malfunction description
Memo
1
F-SENSOR
- When sensor is short, or the temperature is above
65℃
ERROR
running
- When sensor is open, or the temperature is lesser
than -50℃.
2
D1-SENSOR
- When sensor is short, or the temperature is above
65℃
Normal
running
- When sensor is open, or the temperature is lesser
than -50℃.
3
RT-SENSOR
(outer sensor)
- When sensor is short, or the temperature is above
65℃
Normal
running
- When sensor is open, or the temperature is lesser
than -50℃.
4
defrost 1
ERROR
- (defrost 1) It will automatically stop after 80 minutes.
Normal
running