SKF TKTL 31 Скачать руководство пользователя страница 16

skf.com  |  mapro.skf.com  |  skf.com/mount 

®  SKF is a registered trademark of the SKF Group.

©  SKF Group 2020

MP5495

  ·  2020/06

The contents of this publication are the copyright of the publisher and may not be reproduced 
(even extracts) unless prior written permission is granted. Every care has been taken to 
ensure the accuracy of the information contained in this publication but no liability can be 
accepted for any loss or damage whether direct, indirect or consequential arising out of the 
use of the information contained herein.

Содержание TKTL 31

Страница 1: ...Instructions for use SKF TKTL 31 ...

Страница 2: ...5 4 Technical data 6 5 Front panel and button description 8 6 Display overview 10 7 Menu overview 11 8 Measurement settings 12 9 Maintenance 13 9 1 Storage cleaning 13 9 2 LCD error messages 13 9 3 Batteries 13 10 Notes 14 11 Emissivity table 15 12 Spare parts 15 Table of contents Original instructions EN ...

Страница 3: ...ot for intrinsically safe area All repair work should be taken care of by an SKF repair shop Here is a table of hazardous substance name and concentration for TKTL 31 Part name Hazardous Substances Lead Mercury Cadmium Hexavalent Chromium Polybrominated biphenyls Polybrominated diphenyl ethers Pb Hg Cd Cr VI PBB PBDE Laser module The table is prepared in accordance with the provisions of SJ T11364...

Страница 4: ...2 2 2013 Emission CISPR 11 2009 A1 2010 Class B Immunity IEC 61000 4 2 2008 IEC 61000 4 3 2010 IEC 61000 4 8 2009 RED EMC RADIO EQUIPMENT DIRECTIVE 2014 53 EU EN 301489 1 V2 1 1 2017 02 EN 301489 17 V3 1 1 2017 02 RED RF EN 300328 V2 1 1 2016 11 RED EMF EN 62479 2010 EN 62311 2008 RED LVD EUROPEAN LOW VOLTAGE DIRECTIVE 2014 35 EU EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 Laser standards 21...

Страница 5: ...easure target with Lens 8 and press Meas key 6 to display the surface temperature 2 The Distance Spot is 75 1 The two laser points are the reference for the target spot size Please make sure the target area is within the field of view 3 Features LCD black and white display backlit Dual laser targeting Type K thermocouple probe Adjustable emissivity High accuracy Fast response time DS ratio of 75 1...

Страница 6: ...ansmitted energy Distance to spot size 75 1 Spectral response 8 14 µm Emissivity variable 0 1 1 0 Laser Class 2 Maximum laser power 1 mW Laser pointers 2 laser dots Laser wavelength 635 660 nm Display Display LCD black and white display backlit Displayed resolution 0 1 C F from 83 2 999 9 otherwise 1 C F Controls Buttons 4 buttons and 1 trigger Function as per instructions for use User selectable ...

Страница 7: ...80 min 140 hours continuous use without Laser and Backlight Auto switch off Automatic after 60 seconds after trigger is released Probe mode Automatic after 12 minutes Environment Operating temperature 0 to 50 C 32 to 122 F 10 to 95 R H Storage temperature 10 to 60 C 14 to 140 F 10 to 95 R H ...

Страница 8: ...8 EN 5 Front panel and button description 1 2 4 5 3 9 8 10 Item Description 1 Emmissivity key 2 Down key 3 LCD 4 Up key 5 Mode key 8 Infrared lens 9 Laser 10 LED ...

Страница 9: ...9 EN 11 6 7 Item Description 6 Meas key 7 Battery cover 11 Thermocouple socket ...

Страница 10: ...10 EN 6 Display overview Default screen ...

Страница 11: ...n Press Up key 4 or Down key 2 to change the High Alarm HAL or Lo Alarm LAL then press Meas key 6 to confirm it When the reading is outside the High Alarm HAL or Lo Alarm LAL limit The High or Low icon will flash and you will hear a beep sound Connect the thermocouple with Thermocouple socket 11 and put the probe in on the target the thermometer will display the temperature automatically without p...

Страница 12: ...larly useful for continuous monitoring of temperatures for up to 60 minutes Press Down key 3 for ºC or ºF transferred In all modes First hold on the Meas key 6 and press Up key 4 for backlight function ON OFF and press Down key 2 for laser function ON OFF With flash light to be turned on in the same time as laser ...

Страница 13: ...error messages it is necessary to reset the thermometer To reset it turn the instrument off remove the battery and wait for a minimum of one minute reinsert the battery and turn on If the error message remains please contact SKF for further assistance Hi or Lo is displayed when the temperature being measured is outside of the measurement range 9 3 Batteries The thermometer incorporates visual low ...

Страница 14: ...pot aim the thermometer outside the area of interest then scan across with an up and down motion until you locate hot spot Reminders Do not use the unit to measure shiny or polished metal surfaces stainless steel aluminum etc See Emissivity The unit can not measure through transparent surfaces such as glass It will measure the surface temperature of the glass instead Steam dust smoke etc can preve...

Страница 15: ... 80 to 0 95 Water 0 92 to 0 96 Lacquer matt 0 97 Ice 0 96 to 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 85 to 0 95 Glass 0 90 to 0 95 Timber 0 90 Ceramic 0 90 to 0 94 Paper 0 70 to 0 94 Marble 0 94 Chromium oxides 0 81 Plaster 0 80 to 0 90 Copper oxides 0 78 Mortar 0 89 to 0 91 Iron oxides 0 78 to 0 82 Brick 0 93 to 0 96 Textiles 0 90 12 Spare parts Designation Description TMDT 2 30 Contact probe ...

Страница 16: ...right of the publisher and may not be reproduced even extracts unless prior written permission is granted Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct indirect or consequential arising out of the use of the information contained herein ...

Отзывы: