background image

 
 
 

S

KF Multilog On

-Line System IMx-S 

 

A - 1 

User Manual 

Appendix A 
Limited Warranty 

SKF – Limited Warranty 

 

WARRANTY

 

 
Subject to the terms and conditions contained 
herein and provided that there is no applicable 
written agreement between the selling entity in 

the SKF Group (“SKF”) and the Buyer specifically 

covering the sale of the Products (as defined 
below) that includes a product warranty, SKF 

warrants to the Buyer that for the warranty 

period indicated below the products sold by SKF 
that are listed below (the “Products”), when 
properly installed, maintained and operated, will 
be free from defects in material and 
workmanship and shall be fit for the ordinary 
purposes for which the Products are designed. 
 

BUYER’S L

IMITED REMEDIES 

 
This limited warranty defines SKF’s sole and 

exclusive liability and Buyer’s sole and exclusive 

remedy for any claim arising out of, or related 
to, any alleged deficiency in any Product sold by 
SKF, even if such claim is based on tort 
(including negligence or strict liability), breach of 
contract, or any other legal theory.  If the 
Product does not conform to this limited 

warranty, Buyer must notify SKF or SKF’s 

authorized service representative within thirty 
(30) days of discovery of the nonconformity; 
provided, however, that SKF shall not be liable 
for any claim for which notice is received by SKF 
more than thirty (30) days following the 
expiration of the applicable warranty period for 
the Product.  Upon receipt of timely notification 
from 

Buyer, SKF may, at its sole option, modify, 

repair, replace the Product, or reimburse Buyer 
for any payment made by Buyer to SKF for the 

purchase price of the Product, with such 
reimbursement being pro-rated over the 
warranty period. 
 

WARRANTY PERIOD

 

 
Except as expressly provided below, the 
warranty period for each Product shall 
commence on the date the Product is shipped 

by SKF to Buyer.

 

 
90-

DAY WARRANTY

 

 
Products warranted for ninety (90) days by SKF 
are as follows:  cable assemblies, MARLIN 
QuickConnect (MQC), magnetic temperature 
probes, and all refurbished equipment. 
 

ONE

-

YEAR WARRANTY

 

 
Products warranted for one (1) year by SKF are 
as follows: all Microlog products and 
accessories, all Microlog Inspector applications 
including hand-held computers, all MARLIN 
data managers (MDM), all MARLIN Condition 

Detectors (MCD), all Wireless Machine Condition 
Detectors (WMCD), all Multilog On

- line Systems 

(IMx), all Multilog Condition Monitoring Units 
(CMU, TMU), Multilog Local Monitoring Units 
(LMU), all Multilo

g Wireless Monitoring Units 

(WMx), Multilog On

-

line System Wireless 

Vibration Transmitter ISA100, all Wireless 
Monitoring Systems V/T, all Vibration PenPlus, 

all Machine Condition Advisors (MCA), all 
Machine Condition Indicators (MCI), all 
transmitters, all Monitor Interface Modules 
(MIM), all Machine Condition Transmitters 
(MCT), all MicroVibes and Custom Products with 
the prefix of CMCP (with the exception of any 
consumable or expendable items), Shaft 
Alignment Systems TKSA 60 and TKSA 80 
including hand-held computer, measuring units 
and accessories. 
 

TWO

-

YEAR WARRANTY

 

 
Products warranted for two (2) years by SKF 
are as follows: all standard Eddy Probes, Eddy 
Probe Drivers, and Eddy Probe Extension 

Cables, all Multilog On

-line Systems (DMx), all 

Wireless M

achine Condition Sensors, and all 

M800A and VM600 Machinery Monitoring 
Systems. 

Содержание Multilog IMx-S 16

Страница 1: ...0 Fax 46 0 920 134 40 SKF Multilog On Line System IMx S User Manual Part No 32087700 EN Revision R WARNING Read this manual before using this product Failure to follow the instructions and safety prec...

Страница 2: ...t Product Sales For information on purchasing condition monitoring products services or customer support contact your local SKF sales office General Product Information For general product information...

Страница 3: ...r Cables 2 2 Supply Cable 2 3 Cable Glands 2 3 Mains Power 2 3 Communication Cable 2 5 Data Communication 2 5 Ethernet Cable 2 5 Unit Configuration 3 Analogue Inputs 3 1 Digital Inputs 3 3 RS485 Commu...

Страница 4: ...ue Measurement 7 2 Digital Measurement 7 3 Signal Processing 7 3 Interface 7 4 Data Processing 7 4 Miscellaneous 7 4 Quality Control 7 4 IMx S Drawings 8 IMx S 16 Standard Cabinet 8 1 IMx S 16 Stainle...

Страница 5: ...countries you have to be certified in order to connect an IMx S to the power grid Make sure that the power is disconnected before the installation Mains cable must be properly fixed with a cable glan...

Страница 6: ...ending conditions and advanced condition based maintenance to improve machine reliability availability and performance Figure 1 1 System Overview IMx S with ptitude Observer Analyst The picture above...

Страница 7: ...standard trigger sensors and 4 channels for square pulses with trigger level 12 to 24 V Each IMx S 16 unit has 8 MB flash memory with the following storage capacity 2 MB for firmware configuration fi...

Страница 8: ...t in hardware auto diagnosis system continuously checks all sensors cabling and electronics for any faults signal interruption short circuits or power failure Initiating IMx S Initiating the IMx S is...

Страница 9: ...ifferent types of machines can have different safety hazards and safety instructions In all cases read the instructions carefully and act accordingly Important In order to fulfill fire enclosure requi...

Страница 10: ...longer cable lengths are needed fibre optic cables may be used along with needed converters such as converters for fibre optic to CAT5 6 TP Ethernet and vice versa When GPRS is used the GPRS routers...

Страница 11: ...y Important Mains cable must be properly fixed with a cable gland to prevent the cord from strain twist or move See Cable Glands section as well Cable Glands If the sensor cable shields are to be grou...

Страница 12: ...ce Refer to Power Supply in Technical Data section for power requirements Figure 2 1 IMx S Mains Power and Fuse Holder As shown in the picture above a fuse slow blow T2A 250 V 5 x 20 mm is mounted in...

Страница 13: ...which work like an internal network switch Ethernet Cable The Ethernet TP cable on the IMx S is connected at one of the standard Ethernet RJ45 connections Both Ethernet ports have auto detection of cr...

Страница 14: ......

Страница 15: ...ts The figure below shows the screw terminal connections for the IMx S Important The sensor shield should be connected either to the sensor or to the IMx S unit depending on the cable and the sensor t...

Страница 16: ...gs for analogue sensors Signal Terminal DIP Settings position 123456 Standard accelerometer ICP N C Signal Pwr Com Pwr A B 100110 Voltage source N C Signal Com Pwr A B 000000 4 20 mA source N C Signal...

Страница 17: ...h settings while the IMx S unit is powered up as this may cause damage and void warranty Important Before powering up the IMx S unit make sure that DIP switch settings are properly set to match the re...

Страница 18: ...Black Signal Blue 0 V A B 0 0100 0101 Tacho 3 wire PNP 24 V internally powered max 30 mA Brown 24V Black Signal Blue 0V A B 0 1010 1011 Pulse 12 24 V external power N C A B O 0100 0101 Pulse TTL exte...

Страница 19: ...nel for DIP21 no need to remove front panel Table 3 8 DIP21 functionality DIP21 settings position 1234 Functionality with I O board version less than v1 24 DIP21 switch with 4 positions 0100 Terminati...

Страница 20: ...re Controlled Relays Each IMx S 16 has four and IMx S 32 has eight software controlled relay driver outputs labeled as Dig1 OUT through Dig4 OUT see Relay terminal list above These relay driver output...

Страница 21: ...two digital buffered outputs labeled as Dig1 In Buf Output a buffered copy of the Dig1 input as shown in Relay terminal list table above Dig1 In Buf Output copies and buffers the signal from digital...

Страница 22: ...er to ptitude Observer On line Device Configurator User Manual For Analyst clients Multilog IMx Configurator in Admin Tools under SKF ptitude Monitoring Suite There are two ways to configure a network...

Страница 23: ...tup is being done The RS232 connector is located on the right hand side of IMx S front panel labeled as COM Use a serial null modem cable with a 9 pin D SUB connector It is recommended to use a short...

Страница 24: ...x S will continuously synchronize the time with the computer that has ptitude Observer Monitor or Analyst IMx Service running IMx S uses a built in function NTP in Windows for time synchronization In...

Страница 25: ...ltilog On Line System IMx S 4 1 User Manual 4 Hardware Maintenance The IMx S hardware i e the IMx S unit is maintenance free However we advise the customers to do a yearly visual inspection of the equ...

Страница 26: ......

Страница 27: ...should be recycled according to the WEEE directive and not be placed in the general refuse Product should be sent to an approved recycling center for safe recycling recovery reuse or sent to SKF Condi...

Страница 28: ......

Страница 29: ...n on the basis of information in this document Note The guarantee becomes void if IMx S units are damaged through incorrect intervention in the hardware or a patently incorrect connection in contraven...

Страница 30: ...ensor Faulty earthing Incorrect setting in hardware Faulty IMx S input Suggested solution Carry out sensor cable test Load input gives faulty no input signal Possible causes Cable fault short circuit...

Страница 31: ...on Possible causes Monitor PC non functional Monitor software incorrectly set Ethernet switch non functional Cable break in Ethernet network Firewall configuration incorrect Database non functional Su...

Страница 32: ...circuit voltage when one of the sensor cable poles is disconnected from the terminal block of the IMx S unit NO Continue to step 9 6 Did the voltage rise to normal open circuit voltage YES Continue t...

Страница 33: ...sensor or the contact is oxidized First try cleaning the contact before replacing the sensor NO There is a break in the cable Repair the cabling Checking sensor and sensor cabling for analogue channel...

Страница 34: ...g speed input 1 Determine the unit number and speed input of the channel in question through the software measurement point setting or through the list of terminal blocks 2 Measure the signal on the I...

Страница 35: ...ecking monitor 1 Check first whether the ptitude Observer Monitor or Analyst IMx Service PC is functioning as it should be 2 Try restarting the computer if there is any doubt as to the status of the p...

Страница 36: ...rrectly installed Physical connections of RS485 cable wires are done correctly Transmission characteristics are defined correctly The Modbus Master Slave pair address is entered correctly RS485 termin...

Страница 37: ...Mx S 32 500 500 220 mm 19 7 x 19 7 x 8 7 in Weight Standard cabinet IMx S 16 15 0 kg 33 1 lb IMx S 32 21 0 kg 46 3 lb Stainless steel cabinet IMx S 16 21 5 kg 47 4 lb IMx S 32 23 1 kg 50 9 lb Stainles...

Страница 38: ...k Digital Inputs Digital opto isolated inputs IMx S 16 8 IMx S 32 16 Individual 24 V power supply maximum 30 mA per channel IMx S 16 4 channels IMx S 32 8 channels Trigger level range Outputs Relay dr...

Страница 39: ...O board older versions DIP21 switch with 4 positions Required pulse width 4 s for electrical positive 40 s for electrical negative Accuracy frequency 0 05 of measurement value typically 0 01 up to 2...

Страница 40: ...ervice interface 2 port Ethernet network switch possible for daisy chaining Data Processing 64 MB RAM for data processing from serial number 12000 Miscellaneous Calibration traceable to BIPM CE certif...

Страница 41: ...SKF Multilog On Line System IMx S 8 1 User Manual 8 IMx S Drawings IMx S 16 Standard Cabinet Figure 8 1 IMx S 16 Standard Cabinet...

Страница 42: ...IMx S Drawings IMx S 16 Stainless Steel Cabinet 8 2 SKF Multilog On Line System IMx S User Manual IMx S 16 Stainless Steel Cabinet Figure 8 2 IMx S 16 Stainless Steel Cabinet...

Страница 43: ...Mx S Drawings IMx S 32 Standard Stainless Steel Cabinet SKF Multilog On Line System IMx S 8 3 User Manual IMx S 32 Standard Stainless Steel Cabinet Figure 8 3 IMx S 32 Standard Stainless Steel Cabinet...

Страница 44: ...IMx S Drawings Terminal List 8 4 SKF Multilog On Line System IMx S User Manual Terminal List Table 8 1 Terminal list...

Страница 45: ...or reimburse Buyer for any payment made by Buyer to SKF for the purchase price of the Product with such reimbursement being pro rated over the warranty period WARRANTY PERIOD Except as expressly prov...

Страница 46: ...ng Unit CMU Multilog Local Monitoring Unit LMU and the proprietary SKF communications interface with the host computer FIVE YEAR WARRANTY Products warranted for five 5 years by SKF are as follows spec...

Страница 47: ...d by the 90 day warranty stated above THIRD PARTY PRODUCT WARRANTIES For any third party products sold to Buyer by SKF SKF will transfer to Buyer any warranties made by the applicable third party prod...

Страница 48: ...COST OR EXPENSE IN CONNECTION WITH THE PRODUCTS AND RELATED SERVICES IF ANY PROVIDED BY SKF AND THIS DISCLAIMER SHALL EXTEND AS WELL TO ANY LIABILITY FOR NONPERFORMANCE CAUSED BY SKF S GROSS OR ORDINA...

Страница 49: ...ge ESD prevention 2 1 ethernet 2 5 7 4 ethernet cable 2 2 2 5 ethernet LEDs 2 5 F fire enclosure requirements 2 1 frequency range 7 2 7 3 fuse holder 2 3 G GPRS router 2 2 H hardware maintenance 4 1 h...

Страница 50: ...sor cable type 2 2 sensor cables 2 2 set time 3 10 signal processing 7 3 signal to noise ratio 7 2 simultaneous sampling 7 2 SKF ptitude Analyst IMx Service 1 2 SKF ptitude Observer Monitor Service 1...

Отзывы: