Installation

Valve must be installed in direction that 

will permit free rise and fall of float 

assembly. Inspect tank interior for baffles 

that can obstruct float action.

Back off set screw in threaded collar one 

full turn; this will release collar and allow it 

to rotate freely around valve body.

Insert valve assembly into bung opening at 

top of tank. 

Arrow

 on top of valve must 

point to tank area selected for float 

operation.

Hold valve top in position while screwing 

valve collar into tank. Collar is fitted to 

accommodate spanner wrench for 

tightening.

Recheck 

arrow

 to make sure valve is in 

desired operating position before  

tightening collar set screw. When set 

screw is tightened, valve is

 lockedin 

operating position.

Place filters, regulators, oilers and air 

valves in front of air supply line going to 

in

 

port of valve. Never place accessories and 

valves in air supply line from 

out

 port to 

pump.

Maintenance

Overfill warning device is similar to fine air 

tool in that effective life and performance 

can be reduced by dirty air (air that has not 

been filtered to remove moisture and rust 

particles).

Installation of filter, regulator and oiler in 

air supply line going to 

in

 port is 

recommended to minimize fail ures in valve 

and pump. Hydraulic oil or 10 WT motor oil 

is recommended for use in lubricator. 

Antifreeze can be substituted for oil 

whenever combination of extreme cold and 

wet air are present.

Overfill warning device should be tested 

several times per year. Test can be 

accomplished by lifting test button one inch; 

this will cut off air to pump and sound signal  

whistle. Release button and valve will reset.