Safety
Read and carefully observe operating
instructions before unpacking and operating
filter Filter must be operated, maintained
and repaired exclusively by persons familiar
with operating instructions Local safety
regulations regarding installation, operation
and maintenance must be followed
Operate filter only after safety
instructions and this service manual are
fully understood
Explanation of signal
words for safety
NOTE
Emphasizes useful hints and
recommendations as well as
information for efficient and trouble-
free operation
DANGER
Indicates a dangerous situation that will
lead to death or severe injury if
precautionary measures are ignored
Specifications
Model 84013
Model 84013A
Collapse pressure
600 psi (
41,4 bar
)
600 psi (
41,4 bar
)
Screen size
250μ
m
500μ
m
Inlet
1
/
2
in NPTF
1
/
2
in NPTF
Outlet
1
/
2
in NPTF
1
/
2
in NPTF
Maximum working pressure
5 000 psi (
344,7 bar
)
5 000 psi (
344,7 bar
)
Maximum flow rate
1 gallon/minute
(
3,8 liters/minute
)
1.25
gallons/minute
(
4,7
liters/minute
)
Description
Model 84013 and 84013A are grease filters
used to refill small reservoirs of pumps such
as model 203 QuickLub pumps
2
Содержание Lincoln 84013