PRODUCT SPECIFICATIONS
Connector details
54 (66)
SKF Multilog On-line System IMx-16Plus
User Manual
Revision Letter A
3.3 Connector details
3.3.1 IMx-16Plus top end cap
Table 5
IMx-16Plus top end cap connections
Terminal
Description
DC
± for 24-48 V DC supply (connect to lower pair, see
SIM
Micro-SIM card slot (refer
for SIM card orientation)
A
USB A, host interface (Bluetooth dongle normally fitted here)
Eth
RJ45 Ethernet connector (support for Power over Ethernet)
Wi-Fi
Connector for an external antenna (where Wi-fi, used)
USB B
USB mini-B connector, service interface
LTE 1/2
Mobile data connectors for external antenna (where LTE, used)
485 A/B
RS485 2-wire A and B terminals
G
Ground connection for use as required by RS485 and/or CAN
CAN L/N
CAN bus for vehicle systems (No current firmware support)
D1 -D4
4 digital inputs (Ground, Digital, Power terminals for each)
LEDs
Pwr
–
Power (green, normal: on), Sys
–
System (red, normal: off)
Sw
Switch/push button - rescue button (enters maintenance mode)
Demountable terminal connectors
For the top connectors, one 11-way, one 6-way and one 2-way are provided.