Page 92
EN
Fig. 8
Venting the timed lubricator
Oil can discharge while performing the follow-
ing steps.
Requirement: Oil supply unit is switched on.
Set (open) pressure regulating valve (
1
)
on main line to "non-pressurized."
Pressure builds up in the main line,
causing air to low back into the lubri-
cant tank.
Set pressure regulating valve (
1
) to
50 bar.
Loosen vent plugs (
2
and
3
) by 2 to 3
revolutions.
Electrically or mechanically actuate
timed lubricator
(
4
)
until bubble-free oil
discharges at both vent plugs
(for mechanical actuation, see "Trigger-
ing interim lubrication," Chapter 5.3.2).
Tighten vent plugs (
2
and
3
).
Tightening torque 10 Nm
Slightly loosen union nuts (
5
) on the
lubricating oil lines of the timed
lubricator (
4
).
Tighten the union nuts (
5
) when bubble-
free oil discharges.
5.3.1 Venting the lubrication system
- see Figure 6
After the oil supply unit, the main line, and the
timed lubricators have been vented, the lubri-
cation lines to the injector nozzles need to be
vented.
Starting at the oil supply unit, proceed as
follows for each timed lubricator:
Loosen union nuts on all injector nozzles
by one revolution.
Electrically or manually actuate timed
lubricator (using "manual emergency")
until bubble-free oil discharges at the
injector nozzles.
Retighten the union nut.
Repeat these steps on the remaining
injector nozzles.
Clean the outside of the injector nozzles.
5. Commissioning
5.3 Venting the main line and timed lubricator
- see Figure 8