8

Leland Legacy Quick Guide

Terms »

Star button 

•  Scrolls through run time data and Setup options

Up and down arrow buttons 



•  Toggle between display choices and increase or decrease sampling parameters in Setup

Button sequence

 

= press buttons individually

[



] = press simultaneously



 = security code, always press in sequence

Security code 



•  Prevents unauthorized changes to the pump’s sampling program

Programming Sequences »

•  To activate pump (e.g., to change pump from Sleep to Hold):

  Press any button.

•  To change pump from Hold to Run or Run to Hold: 

 Press [



].

•  To reset accumulated data:

  Press  [



], then 



. Press 

 un

til 

CLr

 di

splays then press [



]; press 

 until 

End

 displays then 

press [



]. 

• To set pump 

fl

 ow rate: 

 Press [



], then 



. Flow rate and SET 

fl

 ash. Press 

 or 

 to change 

fl

 ow rate. Press 

 until 

End

 

appears then press [



] to save setting and place pump in Hold.

• To calibrate 

fl

 ow rate with standard calibrator: 

 Press [



], then 



. Flow rate and SET 

fl

 ash. Press 

 or 

 to change 

fl

 ow rate. Press 

 once. 

ADJ

 

displays. Press 

 or 

 until desired 

fl

 ow rate is indicated on calibrator. When 

fi

 nished, press 

 until 

End

 displays 

then press [



] to save new setting and place pump in 

Hold. For CalChek Calibration, see operating instructions.

•  To change temperature scale from F to C or C to F:

 Press [



], then 



. Press 

 until temperature displays. Press 

 or 

 to switch units; press 

 until 

End 

displays then press [



] to save new setting.

•  To change atmospheric pressure scale (mm, mb, In):

 Press [



], then 



. Press 

 until pressure displays then press 

 or 

 to switch units; press 

 until 

End

 displays then press [



] to save new setting.

•  To change time scale (12 Hr/24 Hr/Dela):

 Press [



], then 



. Press 

 until 12 Hr, 24 Hr, or Dela displays then press 

 or 

 to switch units; 

press 

 until 

End

 displays then press [



] to save new setting. 

To set delayed start (Dela), see operating 

instructions.

•  To change clock:

 Press [



], then 



. Press 

 until clock displays then press 

 or 

 to change 

fl

 ashing hour; press 

 to 

move to minutes and 

 or 

 to change setting. Press 

 until 

End

 displays then press [



] to save new setting.

•  To change the sampling time function:

 Press [



], then 



. Press 

 until 

ST L/min

 displays then press 

 to change 

fl

 ashing digit; press 

 until 

End

 displays then press [



] to save new setting. To delete, follow above steps and press 

 until 0 appears. 

Exit Setup.

Note: When in Setup, choosing Esc instead of End will exit Setup without saving new settings.

SKC Inc., 863 Valley View Road, Eighty Four, PA 15330 • www.skcinc.com

Содержание DCS

Страница 1: ...Operating Instructions SKC Deployable Cartridge Sampler DCS System SKC Inc 863 Valley View Road Eighty Four PA 15330 Form 38048 Rev 1812 ...

Страница 2: ...ow rate to 10 L min and record the pre sample flow rate 7 Disconnect calibrator and remove calibration adapter from sampling head 8 Mount bracket at desired location 9 Install sampling head on mounting bracket 10 Install rain cover on sampling head Sampling 1 Turn on pump and record pertinent data Leland Legacy pump may be started manually or automatically see Leland Legacy Quick Guide 2 After des...

Страница 3: ... Pump Operation 6 Charging the Battery 6 Reading the Charging Status LED 7 Battery Setup 7 Battery Replacement 7 Leland Legacy Quick Guide 8 Calibration and Sampling 9 Calibration 9 Sampling 10 Sample Removal and Shipping 11 Removing the Media Cartridge from the Sampling Head 11 Storing and Transporting Samples 11 Ordering Information 12 Li Ion Battery Shipment 13 Warranty 13 Indicates a reminder ...

Страница 4: ...is packaged in a portable heavy duty Pelican case from which the system operates The SKC DCS System includes a Leland Legacy Sample Pump with connection case and cable two external battery assemblies with adapters packaged separately charger 100 240 V sampling head calibration adapter rain cover for sampling head sample tubing with quick connect fitting calibration tubing and mounting bracket in a...

Страница 5: ...omatography high resolution mass spectrometry HRGC HRMS dependent on method used Tubing 3 8 in ID reinforced flexible PVC supplied Temperature Charging 32 to 113 F 0 to 45 C Operating 32 to 104 F 0 to 40 C Storing 4 to 95 F 20 to 35 C Altitude Do not use pump beyond 7500 ft RFI EMI Shielding CE marked Case Dimensions 18 5 x 14 1 x 6 9 in 47 x 36 x 18 cm Complete System Weight 12 20 lbs 5 5 kg Samp...

Страница 6: ...See Figure 2 The aluminum foil wrapped cartridge is supplied in an aluminum can with lid so that the sample is protected from light and contamination during transport The filter and sorbent media are combined for extraction followed by GC MS or HRGC HRMS depending on the method used Inlet section PTFE O ring BUNA N O ring Exhaust section The two main components of the DCS System DCS Sampling Head ...

Страница 7: ...ridge For deployed applications where method specified solvents are unavailable use isopropyl rubbing alcohol or a clean tissue wipe Do not place any mechanical object in the inlet nozzles O ring Care for the Sampling Head Visually inspect the condition of the BUNA N exhaust O ring See Figure 2 Ensure the O ring surface is smooth i e without cracks cuts or other damage Ensure the O ring is fitted ...

Страница 8: ... holder section onto exhaust section 3 Remove media cartridge from aluminum foil and insert into cartridge holder section Ensure airflow arrow on media cartridge points to exhaust section The filter should be on the inlet side of the media cartridge 4 Thread inlet section onto cartridge holder section until just tight Further hand tighten by 1 4 turn only Thread cartridge holder section onto exhau...

Страница 9: ...attery to fire or temperatures in excess of 212 F 100 C Tampering with the battery pack VOIDS ANY WARRANTY Ensure proper orientation of charging cable before plugging it into the charging jack Improper orientation contact will short circuit the battery and VOIDS ANY WARRANTY Short circuiting the battery pack will render it immediately inoperative Failure to follow warnings and cautions VOIDS ANY W...

Страница 10: ...nsert the plug on connecting cable from pump into the jack on the battery adapter on top of the external battery assembly 2 Insert external battery assembly into a foam compartment in the case Ensure there is no tension on the connecting cable Battery Replacement 1 Record all necessary data before unplugging pump from battery 2 Remove plug on connecting cable from jack on battery adapter on top of...

Страница 11: ... new setting and place pump in Hold For CalChek Calibration see operating instructions To change temperature scale from F to C or C to F Press then Press until temperature displays Press or to switch units press until End displays then press to save new setting To change atmospheric pressure scale mm mb In Press then Press until pressure displays then press or to switch units press until End displ...

Страница 12: ...p flow rate to 10 L min see Leland Legacy Quick Guide Record the pre sample flow rate See pump and calibrator operating instructions 1 When calibration is completed disconnect calibrator and tubing from calibration adapter Remove calibration adapter from sampling head Use provided short length of calibration tubing to connect inlet of calibration adapter to outlet of a calibrator to form a calibra...

Страница 13: ...ay be started manu ally or automatically Record all necessary data before disconnecting pump from battery and reconnecting to new battery 4 After desired sample time has elapsed record sample stop time Remove rain cover from sampling head and reinstate calibration adapter tubing and calibrator see Calibration Record post sample flow rate 5 Turn off pump Record total volume ambient temperature ambie...

Страница 14: ...from cartridge holder section 3 Wrap media cartridge in supplied foil or clean aluminum foil and place in supplied aluminum can to protect sample from light and contamination Storing and Transporting Samples 1 Store samples with ice packs 39 2 F 4 C in the field 2 Package and transport samples and blanks with ice packs 39 2 F 4 C until receipt at the analytical laboratory Lift media cartridge from...

Страница 15: ...d a 47 mm quartz filter 226 206 Filter PUF XAD 2 PUF contains a 47 mm quartz filter and 2 grams of XAD 2 sorbent sandwiched between two 20 6 mm lengths of PUF 226 207 Accessories TSI 4146 Calibrator Kit 0 01 to 20 L min includes calibrator soft sided case mounting lugs tubing 1 4 in ID battery pack 6 AA batteries inlet filter dampening module NIST certificate and manual 740 4146 DataTrac for Lelan...

Страница 16: ... 100 watt hours Wh Consult with your carrier for information on Lithium Battery Shipping Regulations UN 3480 and UN 3481 or visit SKC s website for more information at www skcinc com catalog pdf instructions 1921 pdf SKC LIMITED WARRANTY AND RETURN POLICY SKC products are subject to the SKC Limited Warranty and Return Policy which provides SKC s sole liability and the buyer s exclusive remedy To v...

Отзывы: