SKC 590-400 Скачать руководство пользователя страница 4

Form 40123 Rev 1808

Validation

The SKC Hydrogen Cyanide Passive Sampler has been fully validated; see OSHA 
Method 1015.

Reference

Simmons, M., OSHA Method 1015, Hydrogen Cyanide, OSHA Salt Lake Technical Center, Nov. 2010, 
h

tt

 p://www.osha.gov/dts/sltc/methods/validated/1015/1015.pdf

Ordering

Description

Cat. No.

Hydrogen Cyanide Passive Samplers*

 include empty sampler 

housings and sealed glass vials of 600 mg soda lime sorbent, pk/5

590-400

* HCN Passive Samplers are designed for single use only. Do NOT reuse HCN samplers.

SKC Limited Warranty and Return Policy

SKC products are subject to the SKC Limited Warranty and Return Policy, which 
provides SKC’s sole liability and the buyer’s exclusive remedy. To view the complete 
SKC Limited Warranty and Return Policy, go to h

tt

 p://www.skcinc.com/warranty.

Содержание 590-400

Страница 1: ...sorbed with water and analyzed by ion chromatography electrochemical detector The HCN Passive Sampler is designed for single use Performance Profile Sorbent Amount Soda Lime 600 mg supplied in glass vial Housing Material Nylon Diameter 1 4 in 3 5 cm Length including clip 2 5 in 6 3 cm Measuring Range 0 44 to 20 ppm Analysis Solvent extraction ion chromatography IC with electro chemical detector EL...

Страница 2: ... vial adapter until secure see inset 3A Rotate entire assembly until sorbent is draining from vial to sampler Figure 3 Tap vial lightly before unscrewing and removing it from the adapter Immediately replace plug on vial adapter Store sorbent vial and cap in aluminized pouch Record start time on the sampler label Remove cover from face of sampler housing side with holes immediately before sampling ...

Страница 3: ...Ensure sorbent vials are capped tightly HCN Passive Samplers are designed for single use only Do NOT reuse HCN samplers Sample Storage 3 weeks at 68 F 20 C in a clean environment in storage studies Note OSHA Method 1015 recommends that samples be sent to a laboratory as soon as possible If delay is unavoidable store samples in a refrigerator as a precaution Analysis Preparing the Sample 1 Remove s...

Страница 4: ...on Cat No Hydrogen Cyanide Passive Samplers include empty sampler housings and sealed glass vials of 600 mg soda lime sorbent pk 5 590 400 HCN Passive Samplers are designed for single use only Do NOT reuse HCN samplers SKC Limited Warranty and Return Policy SKC products are subject to the SKC Limited Warranty and Return Policy which provides SKC s sole liability and the buyer s exclusive remedy To...

Отзывы: