SKC 224-6580 Скачать руководство пользователя страница 6

Page 4 

007-08-001 Issue C 

www.skcltd.com

Warranty Information

Limited One Year Warranty

1. SKC warrants that this instrument, and each of its component parts, provided for occupational health and 
safety and environmental applications is free from defects in workmanship and materials under normal use for 
a period of one (1) year. This warranty DOES NOT cover any claims due to abuse, misuse, neglect, alteration, 
or accident, or use in application for which the instrument was either not designed or not approved by SKC, or, 
due to the buyer’s failure to maintain normal maintenance, improper selection or misapplication.  The warranty 
also DOES NOT cover any claims due to the use of a non-SKC approved charger to charge the battery pack. 
This warranty shall further be void if changes or adjustments to the instrument are made by a person other than 
an employee of the seller or, if the operating instructions furnished at the time of installation are not complied 
with.
2. SKC hereby expressly disclaims all warranties either expressed or implied, including any implied warranties 
of merchantability or fitness for a particular purpose and neither assumes nor authorises any person to assume 
for it any liability in connection with the sale of these instruments.  No description of the goods being sold has 
been made a part of the basis of the bargain or has created or amounted to an express warranty that the 
goods will conform to any such description.  Buyer shall not be entitled to recover from SKC any consequential 
damages; damages to property, damages for loss of use, loss of time, loss of profits or income or any other 
incidental damages.  Nor shall the Buyer be entitled to recover from SKC any consequential damages resulting 
from defect of the instrument.
3. This warranty extends only to the original purchaser of the warranted instrument during the term of the 
warranty, the buyer may be required to present proof of purchase in the form of a paid receipt for the instrument.
4. In the event of a defect, malfunction, or other failure of  the instrument not caused by any misuse or damage 
to the instrument while in the possession of the Buyer, SKC will remedy the failure or defect without charge to 
the buyer.  The remedy will consist of service or replacement of the instrument, or refund of the purchase price, 

Содержание 224-6580

Страница 1: ...www skcltd com Pneumatic Test Kit Operating Instructions This manual covers the following model 224 6580 ...

Страница 2: ... this product The first service is due one year from the date of purchase and then at yearly intervals on this date Service Date Service Date Service Date 1 5 9 2 6 10 3 7 11 4 8 12 Please note that SKC Ltd are the only authorised service centre in the UK guaranteeing you access to the full range of genuine SKC replacement parts For all other areas a full list of SKC approved distributors and serv...

Страница 3: ... 5 of full scale Flow Scale Standardization Air at 20 C and 1013 25 mbar absolute Back Pressure Range 0 to 80 inches H2 O Back Pressure Accuracy 2 of full scale Control Layout Back pressure gauge Zero adjust screw Back pressure bypass valve Sample pump hosetail connection Flow meter Back pressure adjuster valve Air inlet sample head hosetail connection ...

Страница 4: ...uge reads zero and adjust using the zero adjust screw if required 2 Ensure that the sample pump battery is fully charged Run the sample pump for five to ten minutes prior to carrying out pump compensation or sample media back pressure checks Sample Pump Compensation Verification Refer to the sample pump instruction manual or SKC Ltd for pump compensation specification 1 Connect the inlet hosetail ...

Страница 5: ...ssure of 2 4 inches H2 O setting the required flow rate then increasing the back pressure to the required level Sample Media Back Pressure Check 1 Connect the inlet hosetail of the pump to the pump connection hosetail on the pneumatic test kit using a length of flexible tubing 2 Place the sample media into the sample head and connect the sample head outlet to the air inlet connection hosetail on t...

Страница 6: ... implied warranties of merchantability or fitness for a particular purpose and neither assumes nor authorises any person to assume for it any liability in connection with the sale of these instruments No description of the goods being sold has been made a part of the basis of the bargain or has created or amounted to an express warranty that the goods will conform to any such description Buyer sha...

Страница 7: ...To obtain performance of any obligation under this warranty the buyer shall return the instrument freight prepaid to SKC at the following address SKC Limited 11 Sunrise Park Higher Shaftesbury Road Blandford Forum Dorset DT11 8ST t 44 0 1258 480188 f 44 0 1258 480184 6 b To obtain further information on the warranty performance contact SKC 7 This warranty is provided under English law 8 No other w...

Страница 8: ...al group of companies SKC Limited 11 Sunrise Park Higher Shaftesbury Road Blandford Forum Dorset DT11 8ST United Kingdom T 44 0 1258 480188 F 44 0 1258 480184 E info skcltd com W www skcltd com 007 08 001 Issue C November 2010 ...