SJOBLOMS A5-011-8551 Скачать руководство пользователя страница 10

 

300kg exam table 

Operation

 

 

 

The Castors 

SJÖBLOMS 

+46 660 842 51 

[email protected] 

2.8 The function of the castors 

The table is equipped with central locking castors including a directional locking 
function. 

 

Press the red side to lock the castors. 

Press the green side to activate the directional locking function. 

Have the castors as shown above for a free mode. 
 

 

 

Содержание A5-011-8551

Страница 1: ...NUAL TWO SECTIONED EXAMINATION TABLE 300 KG LIFTING CAPACITY For model A5 011 8551 NOTE The operator must read the user manual carefully BEFORE the product is used to avoid unnecessary risks to the pa...

Страница 2: ...ckrest 2 5 Adjusting the Trendelenburg position 2 6 Replacing the paper roll 2 7 Paper dispenser 2 8 The function of the castors 2 9 Side rails 2 10 IV stand 3 Maintenance Cleaning 3 1 Routine examina...

Страница 3: ...d Therefore we reserve against possible changes in the user manual WARRANTY Sj bloms provides a two year warranty for material design and manufacturing defects provided the products are not subjected...

Страница 4: ...must only be used by competent health professionals who read the user manual for correct handling General description 2 sectioned examination table electrically adjustable chromium plated or coated a...

Страница 5: ...660 842 51 info sjobloms com 2 OPERATION 2 1 When the patient sits down We recommend to always have the castors locked when the patient sits down For maximum safety have the patient sit down on the m...

Страница 6: ...utlet The product is now ready for use 2 3 Height adjustment Electric hand control standard Electric foot control option NOTE Ensure that no unauthorized persons are in the couch s working range as a...

Страница 7: ...ht pair regulates the backrest The left pair regulates the height of the table The right pair regulates the backrest and or the Trendelenburg position Press the middle switch to change between the two...

Страница 8: ...r regulates the backrest and or the Trendelenburg position Press the middle switch to change between the two functions The left pair regulates the height of the table Electric hand control Follow the...

Страница 9: ...tear off edge Tear off the old paper on the tear off edge and the table is ready to be used again a Unscrew the black ball b Push the metal rod to the left c Pull the rod gently towards you until it c...

Страница 10: ...m 2 8 The function of the castors The table is equipped with central locking castors including a directional locking function Press the red side to lock the castors Press the green side to activate th...

Страница 11: ...660 842 51 info sjobloms com 2 9 Side rails 1 Lift the black ball 2 Fold the siderails using the other hand in the direction of the arrow 3 Done 4 When raising the siderails make sure its mechanic cli...

Страница 12: ...nce Cleaning Routine check ups SJ BLOMS 46 660 842 51 info sjobloms com 2 10 IV stand NOTE Pinch hazard exists when raising and lowering the side rails The IV stand may be adjusted in height Lock open...

Страница 13: ...d castor locking mechanism Damages to electric cables The motor functions That joints and fittings are lubricated according to the lubrication chart 3 2 Cleaning Cleaning artificial leather Water and...

Страница 14: ...Lubrication Lubrication according to the schedule should be performed every 6 months or as needed 1 First lock the castors 2 Enlist the help of another person and tip the couch on the side in order t...

Страница 15: ...arts 5 6 7 Nr Art nr Ben mning 1 312100 3115004C Motor ryggst d 2 312100 1110004C Motor chockl ge 3 343100 0015004A Motor lyft 4 CB9140AE3 0001J Styrenhet 5 12560150OT2LPV Hjul 6 12560150OT3LPV Hjul r...

Страница 16: ...300kg exam table Maintenance Cleaning Accessories SJ BLOMS 46 660 842 51 info sjobloms com 3 5 Accessories Sidogrindar Infusionsstativ...

Страница 17: ...leaning and disinfecting SJ BLOMS 46 660 842 51 info sjobloms com 3 6 Solutions for lubrication cleaning and disinfecting R 1 Cleaning solution for artificial leather 5557001 Lubrication C068 Disinfec...

Страница 18: ...pecifications Dimensions SJ BLOMS 46 660 842 51 info sjobloms com 4 TECHNICAL SPECIFICATIONS 4 1 Dimensions Length 205 cm Width 80 cm Height 55 85 cm Length of backrest 75 cm Weight ca 90 kg Max patie...

Страница 19: ...tors comply with EMC directives in accordance with standard EN 60601 1 2 At full load the motors can be used a maximum of 6 minutes hour The actuator manufacturer guarantees at least 10 000 cycles per...

Страница 20: ...lose its stored energy It is therefore recommended that the batteries are recharged at least 8 hours before usage Battery life Battery life depends on several factors including the extent of discharg...

Страница 21: ...the product The CE label contains the date order number serial number and our contact information Max patient weight 300 kg Displays the adjustment of the back rest There is a label on each side of th...

Страница 22: ...Model A5 011 8551 Product registration number 64509 The appendix contains documents that have been applied for verification of compliance Manufacturer Sj bloms Sjukv rdsutrustning AB Myr ngsv gen 8 S...

Страница 23: ...ontact information SJ BLOMS 46 660 842 51 info sjobloms com 6 CONTACT INFORMATION SJ BLOMS Myr ngsv gen 8 891 50 rnsk ldsvik Sweden Tel 46 660 842 51 Fax 46 660 180 00 E mail info sjobloms com Web pag...

Отзывы: