SJE Rhombus Three Phase Duplex Скачать руководство пользователя страница 2

Lag

Lag

Lag

Alarm

Stop

Stop

Stop

Alarm

Lead

Lead

Lead

Alarm

Operating
range

Installing the Float Switches

The Model 322 Three Phase Duplex control panel operates with 
fl oat switches.  They activate pump STOP, LEAD pump START, 
LAG pump START and high-level ALARM functions.

Mounting the Control Panel

1

2

3

CAUTION!

NOTE

Ensure all power is turned OFF 
before installing fl oats in tank. 
Failure to do so could result in 
serious or fatal shock.

If the fl oats are not properly mounted and connected in the correct 
order, the pumps will not function properly.

Label each fl oat and cord end 
with the provided pairs of 
STOP, LEAD, LAG, and ALARM 
stickers.

If the distance to the control panel exceeds the length of 
the fl oat switch cords or the pump power cord, splicing 
in a liquid-tight junction box will be required.  For outdoor 
or wet installation, we recommend an SJE Rhombus, UL 
Type 4X junction box.

2

Make sure hose clamp 
band does not interfere 
with fl oat operation.

Do not install cord under
hose clamp.

Tighten 
the 
clamp.

Floats require free range of motion.  

They must not touch each other or any equipment in the pump chamber.

LEAD

LEAD

STOP

STOP

Hose clamp is 18-8 
stainless steel. 

3.5”

(9cm)

Pipe Clamp Mounting

4 Float Operation

Pipe Clamp Mounting

3 Float Operation

Lag/Alarm

Stop

Stop

Stop

Lag/Alarm

Lead

Lead

Lead

Lag/Alarm

Operating
range

Содержание Three Phase Duplex

Страница 1: ... to health hazards in handling said material All applicable laws and regulations shall apply Installation and Operation Manual Model 322 Three Phase Duplex Installation and Operation Manual This control panel must be installed and serviced by a licensed electrician in accordance with the National Electric Code NFPA 70 state and local electrical codes UL Type 4X enclosures are for indoor or outdoor...

Страница 2: ...t and cord end with the provided pairs of STOP LEAD LAG and ALARM stickers If the distance to the control panel exceeds the length of the float switch cords or the pump power cord splicing in a liquid tight junction box will be required For outdoor or wet installation we recommend an SJE Rhombus UL Type 4X junction box 2 Make sure hose clamp band does not interfere with float operation Do not inst...

Страница 3: ...p OFF In AUTO mode commands from the float switches turn each pump ON and OFF Motor Contactors Motor contactors control pumps by switching electrical lines Transformer The transformer converts incoming three phase power to 120V to be used for control and alarm Auxiliary Contact Form C Can be wired normally open or normally closed 1 Determine conduit entrance locations on control panel as shown Che...

Страница 4: ...RED PUMP LIGHT NO SEAL FAIL FLASHING SF1 SF2 PROG FLOAT FAIL FLASHING BAD FLOAT NOT LIT NO HIGH ALARM SOLID ALARM FLOAT YES 1 2 ALT 2 1 SF1 SF2 SEAL FAIL LEAD LAG SELECTOR 25K 5K NC 150K 100K 125K 50K 15K 100K AUX ACTS NO C NC TB2 H O H O PUMP 1 PUMP 2 H O A PUMP 1 PUMP 2 H O A H O A H O A TM ON OFF STOP LEAD LAG ALARM TEST TEST TEST TEST TEST TEST TEST CONT NO C NC 4 5 6 7 8 9 10 3 TB1 ON OFF L1 ...

Отзывы: