Instl Instr. PN 1012018D    

   INSTALLING THE AUTO DIALER

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this 
product. A qualifi ed service person must install and 
service this product according to applicable electrical 
and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with fl ammable liquids. 
Do not install in hazardous locations as defi ned by 
National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged 

or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/

NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fi ttings, fl oat housing, or cable. 

   TESTING THE AUTO DIALER

   PROGRAMMING  THE AUTO DIALER

   PROGRAMMING  TIPS

FIGURE A

TWO NORMALLY CLOSED CONTACTS

FIGURE B

TWO NORMALLY OPEN CONTACTS

Note:

 Temperature switch can also be used by itself. See 

Figure C.

FIGURE C

  

Note:

 These instructions are intended as a quick reference for the most 

common installation of the Auto Dialer when used with a control 
panel. For complete instructions, see the included 

Installation 

and Instruction Manual for the Automatic Voice Dialer

. Before 

beginning installation, read the entire instruction manual for the 
AVD-45b Automatic Voice Dialer.

  1.  Determine indoor mounting location for the Auto Dialer.
    2.  If mounting the Auto Dialer to the wall, use the two supplied screws. 

Install the screws parallel and level  5 3/16 inches apart.

  3.  Install the four conductor power/alarm cable into a control panel 

using only the white and yellow conductors. The conductors can 
be attached to normally open or normally closed contacts. 

Note:

 

Trim the red and black conductors fl ush with outer jacket of the 
cable. (See Figures A & B for optional wiring methods.)

    4.  Install the two conductor telephone cable by matching the appropriate 

colors to a telephone service or by installing an appropriate 
connector. 

  5.   Install the 9 VDC battery if backup power is desired. 

Note:

 The 

battery will supply approximately four hours of backup power. 
Replace battery yearly and after each power outage.

    6.      Hang the auto dialer on the two mounting screws previously installed. 
  7.  Connect the phone cable and power/alarm cable to the auto dialer 

using the supplied connectors.

    8.      Install the barrel connector on the power supply into the connection 

labeled 

12V standby battery

.

  9.   Plug the DC power supply into a standard outlet.

  

1.  Program the Auto Dialer according to the 

United Security Products 

Model AVD-45b Automatic Voice Dialer

 instruction manual.

  2.  Be sure to note if normally open or normally closed contacts are 

used to trigger the Auto Dialer. This will have to be programmed 
into the Auto Dialer.

 

 1.  When programming for pagers, call the desired pager from the 

telephone number and telephone line that the Auto Dialer will 
be attached to. Record the time required for the pager service to 
answer. Use that time for programming the required number of 
pauses needed. Each pause is two seconds in length.

  2.  If a cell phone does not ring before the Auto Dialer hangs up, 

program the cell phone number into the Auto Dialer with pauses 
after the number. Note: The number of pauses will depend on each 
cell phone and must be tested.

  3.  If a delay is desired before the Auto Dialer calls out to help prevent 

nuisance calls, set the entry delay to "on" and the channel to 
"continuous" mode. This will require that channel activation to be 
tripped for 20 seconds before dialing out and remain activated 
throughout the dialing process.

  1.  All people or organizations should be notifi ed that the auto dialer 

will be calling and the action you would like them to take.

  2.  Apply power to the unit. 
  3.  Be sure an active telephone line and all wiring is connected to the 

auto dialer.

  4.  Press the "M" key until "Operate" appears in the LCD.
  5.   Trigger the signaling device to cause the auto dialer to call out.
  6.   The auto dialer will dial the numbers stored in locations 1-4. The 

out going message will be delivered when the auto dialer receives 
an answer. For pager numbers, the pager code will be transmitted 
instead of the outgoing message.

  7.   The auto dialer is now ready for operation.
  8.  Test the Auto Dialer system once a month to insure the outgoing 

message is being sent and received.

For detailed specifi cations on this product, or for the complete line of SJE-Rhombus

®

 

panel, alarm, and switch products, visit our web site at www.sjerhombus.com.

Note:

 The Auto Dialer AVD-45b will attempt to deliver the outgoing message twice with a maximum of 10 attempts for each telephone number.

Note:

 This device should not be used for life saving applications.