Single Phase Duplex

SJE-Rhombus

®

 Type 123

Installation Instructions and Operation/Troubleshooting Manual

22650 County Highway 6  

n

   P.O. Box 1708

Detroit Lakes, Minnesota 56502 USA

1-888-DIAL-SJE (1-888-342-5753)

Phone: 218-847-1317  

n

   Fax: 218-847-4617

E--mail: [email protected]

Website: www.sjerhombus.com

©SJE-Rhombus

PN1009560D • Rev 11/14

Manufactured by:

Installation

Warranty void if panel is modified.

Call factory with servicing questions:

1-800-RHOMBUS

(1-800-746-6287)

This control panel must be installed and serviced by a licensed 

electrician in accordance with the National Electric Code NFPA-70, state 

and local electrical codes. 

All conduit running from the sump or tank to the control panel must be 

sealed with conduit sealant to prevent moisture or gases from entering the panel. 

NEMA 4X enclosures are for indoor or outdoor use,

 primarily to provide 

a degree of protection against corrosion, windblown dust and rain, splashing 

water and hose-directed water. 

Cable connectors must be liquid-tight in 

NEMA 4X enclosures.

Most Type 123 panels are designed to operate as three or four float systems. 

The three float system is standard performing the common pump stop, lead 

pump start, and lag pump start/high level alarm functions. The four float system 

utilizes separate floats for lag pump start and high level alarm.

NOTE: Options ordered may affect the number of floats and their func

-

tions.  Please reference the schematic provided with the control panel 

for proper installation.

Installation of Floats

CAUTION: 

If control switch cables are not wired and mounted in the correct 

location, the pump system will not function properly.

WARNING:

 Turn off all power before installing floats in pump chamber. Failure 

to do so could result in serious or fatal electrical shock.

1.  

Use float label kit to identify and label cables on both float and stripped 

ends (stop, lead, lag, alarm, etc.). See schematic for float options.

2.

  Determine your normal operating level, as illustrated in 

Figures 1-2

3. 

  Mount float switches at appropriate levels as illustrated in 

Figures 3-5

.

 

 Be 

sure that floats have free range of motion without touching each other, or 

other equipment in the basin.

If using the mounting clamp; follow steps 4-6.

4. 

Place the cord into the clamp as shown in

 Figure 5

.

5. 

Locate the clamp at the desired activation level and secure the clamp to 

the discharge pipe as shown in 

Figure 5

.  

 NOTE:

 Do not install cord under hose clamp.

6. 

  Tighten the hose clamp using a screwdriver. Over tightening may result in 

damage to the plastic clamp. Make sure the float cable is not allowed to 

touch the excess hose clamp band during operation.

 NOTE:

 All hose clamp components are made of 18-8 stainless steel 

material. See your SJE-Rhombus

®

 supplier for replacements.

Содержание 123

Страница 1: ...separate floats for lag pump start and high level alarm NOTE Options ordered may affect the number of floats and their func tions Please reference the schematic provided with the control panel for proper installation Installation of Floats CAUTION If control switch cables are not wired and mounted in the correct location the pump system will not function properly WARNING Turn off all power before ...

Страница 2: ...nduit connectors to control panel FOR INSTALLATION REQUIRING A SPLICE FOLLOW STEPS 6 10 Installation Instructions FIGURE 5 Mounting clamp detail FIGURE 3 Internally weighted float FIGURE 4 Float with cable weight FOR INSTALLATION WITHOUT A SPLICE GO TO STEP 11 6 Determine location for mounting junction box according to local code requirements Do not mount the junction box inside the sump or basin ...

Страница 3: ... a short time delay the indicator light will turn on When the condition is cleared the relay will de energize and the indicator light will turn off The seal fail relay has a sensitivity adjustment so that false readings may be tuned out Dry Auxiliary Contacts optional Normally open Contacts are open under normal conditions and closed when alarm condition is present Normally closed Contacts are clo...

Страница 4: ...es and E to units repaired and or modified without prior authorization from SJE RHOMBUS Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rig...

Отзывы: