Thank you for purchasing our smoke alarm!

 

Please read these instructions carefully and store them in a safe place 
where you can access them easily.

 

 

Product description and intended use

 

This is a smoke alarm with an optical sensor for installation in residential 
buildings, apartments and rooms with residential-like use. Smoke alarms 

are designed to provide an early warning of fire smoke and fires to 

persons present, so that these persons can react appropriately to the 
hazardous event. Always consult local regulations for smoke alarms.

 

 
 

 
 

 

Test button 

Sound output 

LED indicator

 

 

 

 

 

Product specifications

 

Detection method 

:  Optical

 

Power supply 

: Sealed battery

 

Battery lifetime 

: 10 years

 

Alarm volume 

: > 85 dB (A) at 3 meters

 

Alarm sensitivity 

: 0,096 - 0,148 dB/m

 

Monitored area 

: 20 - 40 m² 

Operating temperature 

: 0 °C - 40 °C 

Operating humidity 

: < 93 %

 

Date of replacement 

: See product label 

Individual alarm indicator 

:  Yes

 

Alarm silence facility 

: Yes | Hush time: 5-15 minutes 

Low battery warning 

: Yes  

Low battery silence facility 

: Yes | Hush time: 10 hours 

Installation in leisure

 

accommodation vehicles 

: Yes 

Mounting location 

: Ceiling

 

Interconnectable 

:  No

 

 

Warnings:

 

• 

To prevent injury, this apparatus must be securely attached to the 
ceiling in accordance with the installation instructions.

 

• 

Batteries should not be exposed to excessive heat such as sunshine, 
fire or the like.

 

• 

Do not paint or cover the smoke alarm.

 

Where to install a smoke alarm

 

Smoke alarm must be installed in such a way that it can be reached 
unhindered by the fire smoke so that fire can be reliably detected during 

the development phase.

 

• 

Install at least in sleeping areas (especially children's rooms);

 

• 

Install at least in escape rooms;

 

• 

In the middle of the ceiling of a room;

 

• 

At least 50 cm away from the wall and other objects;

 

• 

Maximum installation height of 6 meter.

 

 

 

 

  

Minimum

 

  

Optimal

 

 

Restrictions

 

 

Where to install a smoke alarm in rooms 
with special geometries

 

• 

Corridors with a maximum width of 3m: Max. 15m between 2 smoke 
alarms. Max. 7,5m to the front side of the gallery and smoke alarms 

at edges/crossings of corridors.

 

• 

Rooms with sloping ceilings:

 

-

 

If the ceiling inclination is > 20° to the horizontal: Smoke 

alarms must be installed at least 0.5 m and at most 1 m 
from the ceiling top.

 

-

 

Partial roof slopes: If the flat ceiling is ≤ 1m wide, consider 

as ceiling inclination is of > 20°. If the flat ceiling is >1m 
wide, consider as flat ceiling.

 

• 

Rooms with subdivided ceilings:

 

-

 

Height of the subdivisions is ≤ 0.2 m: Beams without consideration; 
smoke alarm may be installed on the beams as well as on the 

ceiling.

 

-

 

Height of subdivisions is > 0.2 m and area of ceiling panels > 36 m²

 

: Smoke alarm should be installed in each ceiling panel.

 

-

 

Height of subdivisions > 0.2 m and area of ceiling panels ≤ 36 m²

 

: Individual ceiling without consideration.

 

 

Where not to install a smoke alarm

 

• 

In an environment with a high risk of draught (e.g. close to air 
conditioning, fans and ventilation outlets). The movement of air can 

impair the penetration of fire smoke into the smoke alarm.

 

• 

Areas where occurs combustions regularly, such as kitchens.

 

• 

Areas with high humidity such as bathrooms, or close to devices such 

as dish washers or washing machines.

 

 

Activation

 

• 

Before commissioning the smoke alarm, it is important to activate 

and test it for correct operation.

 

• 

Place the mounting plate on the smoke alarm and secure it by 
turning it clockwise. When it’s properly tightened, the smoke alarm is 

activated by the activation switch and generates a loud beep.

 

• 

Test the correct activation of your smoke alarm by pressing the test 

button. If no sound is generated, the smoke alarm is not activated 

properly and should not be used!

 

 

Mounting

 

• 

Remove the mounting plate from the smoke alarm;

 

• 

Place the mounting plate on a desired installation location and mark 
where the holes should be drilled;

 

• 

Drill two holes with a diameter of 5 millimeters;

 

• 

Push the plastic plugs into the holes;

 

• 

Insert the screws into the mounting plate, and tighten them firmly into 

the plugs;

 

• 

Place the smoke alarm on the mounting bracket and secure it by 

turning it clockwise;

 

• 

When it’s properly tightened, the smoke alarm generates a beep;

 

• 

Test the correct operation of your smoke alarm by pressing the test 

button. If no sound is generated, the smoke alarm is not functioning 

properly and should not be used!