Instruction Manual
CARBON MONOXIDE ALARM
Thank you for your support
Please read the instruction manual carefully before operating
Please keep the instruction manual
for future reference
SITERWELL ELECTRONICS CO.,LIMITED
Страница 1: ...ction Manual CARBON MONOXIDE ALARM Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual for future reference SITERWELL ELECTRONICS CO LIMITED ...
Страница 2: ...S816B Type of apparatus Type A Power Supply DC 3V 2pcs alkaline battery Recommend battery type GP GN15A Raymax LR6 Sensor Type Electrochemical Product life 10 years after initial power up Sensitivity Setting Conforms to EN 50291 1 2010 A1 2012 standard 30PPM Without alarm before 120 minutes 50PPM Between 60 to 90 minutes 100PPM Between 10 to 40 minutes 300PPM Less than 3 minutes Standby Current 50...
Страница 3: ...COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION COMMAND_CLASS_WAKE_UP COMMAND_CLASS_SUPERVISION Supported Notification Type CO Alarm 0x02 CO Alarm Supported Event a Carbon monoxide detected Unknown Location 0x02 b Carbon monoxide Test 0x03 c Replacement Required Unspe...
Страница 4: ...he devices status sending BASIC SET control frame to the associated devices having detected the CO leak Linkage group 3 reports the detection s status to the associated device The maximum number of devices that can be added to the linkage group 1 is 5 number linkagegroup2 or linkage group3 is 5 numbers This product will send a BASIC SET 0xFF message to associated group when press and release the t...
Страница 5: ...damp and humid areas such as the bath room Avoid spraying aerosols near the CO alarm Do not install in areas where the temperature is below 10 or hotter than 40 Do not place behind curtains or furniture CO must be able to reach the sensor for the unit to accurately detect CO Do not place near metal objects otherwise it will affect the distance of wireless signal transmission Tips 1 Start up After ...
Страница 6: ...FAULT indicator yellow LED flashing twice every 30 seconds indicates that the battery is low battery you must to replace the battery with battery specified To install or replace the battery in unit please perform the following steps 1 Take down the unit from screw heads of the wall 2 Open battery compartment 3 Remove the old battery and replaced by new battery 4 Close battery compartment 5 Hook th...
Страница 7: ...s a colourless odourless non irritating gas classified as a chemical asphyxiant and whose toxic action is a direct result of the hypoxia produced by a given exposure CO is rapidly absorbed through the lungs diffuses across the alveolar capillary membrane and is reversibly bound with haemoglobin as carboxyhaemoglobin COHb however a minute amount is present in the plasma The affinity of haemoglobin ...
Страница 8: ...us will not fully safeguard individuals at special risk Manufacturer and Service information SITERWELL ELECTRONICS CO LIMITED ADDRESS NO 76 HAICHUAN ROAD CHUANGYE ZONE B JIANGBEI NINGBO CHINA TEL 0086 0574 87729581 FAX 0086 0574 87729581 E MAIL Sales china siter com Guarantee THREE YEARS LIMITED WARRANTY Dear customer Our products are subject to strict quality controls However if this device shoul...