SITERWELL ELECTRONICS CO.,LIMITED GS526A Скачать руководство пользователя страница 2

INSTALLATION NOTE

SITERWELL ELECTRONICS CO ., LIMITED

Address:NO.666 Qingfeng Road, Jiangbei District, Ningbo, Zhejiang Province, China
Tel: 0086-574-87729581                          Fax: 0086-574-87729581
E-mail: [email protected]        Http://www.china-siter.com

If you are not sure about the insulation in your mobile home, or if you notice that the 
outer walls and ceiling are either hot or cold, install the alarm on an inside wall. For 
minimum protection, install at least one alarm close to the bedrooms. For additional 
protection, see SINGLE FLOOR PLAN in Figure 3 and MULTIPLE FLOOR PLAN in 
Figure 4. 

• When mounting an alarm on the ceiling, locate it at a minimum of 4" (10cm) from 
  the side wall (see figure 1).

• When mounting the alarm on the wall, use an inside wall with the top edge of the 
  alarm at a minimum of 4"(10cm) and a maximum of 12"(30.5cm)below the ceiling  
  (see figure 1).

• Put smoke alarms at both ends of a bedroom hallway or large room if the hallway 
  or room is more than 30 ft (9.1 m) long.

• Install Smoke Alarms on sloped, peaked or cathedral ceilings at or within 3 ft 
  (0.9m) of the highest point (measured horizontally). NFPA72 states: "Smoke 
  alarms in rooms with ceiling slopes greater than 1 ft in 8 ft (.3m in 2.4m) horizontally 
  shall be located on the high side of the room. " NFPA 72 states: "A row of alarms
  shall be spaced ac'usmated within 3 ft (0.9m) of  the peak of the ceiling measured 
  horizontally" (see figure 2).

Low battery trouble indication: An intermittent “chirp” accompanied by a red LED flash every 40 seconds indicates 
a low battery, you may press the test button to silence the trouble indication for 10 hours, but it will reset automati-
cally after 10 hours. During this condition the unit will continue to operate normally and detect smoke and sound an 
alarm. This action only temporarily silences the chirp.
NOTE: As the battery in this unit is not replaceable, a low battery signal is an indication of end of life. Therefore the 
alarm MUST be replaced as soon as possible!
Fault indication: This chirp will occur between the flashes of the red LED indicator light. 
Battery discharge Condition: The red LED will always light ( This is another red LED of other position).
NOTE: When the unit chirps once every 40 seconds, pressing the test button temporarily silences this warning tone 
for 10 hours.

 

SINGLE FLOOR PLAN    

Figure 3

 

 

Smoke Alarms for Minimum Protection
Smoke Alarms for Additional Protection

Ionisation Type Smoke Alarm with Alarm Silencer or Photoelectric Type

MULTIPLE FLOOR PLAN 

Figure 4