background image

 

3

 

      

Electronic Combination Cam Lock ”Dave”

 

SISO A/S

 

  

  

  

Mileparken 11

 

DK

-

2740 Skovlunde

 

Denmark

 

Phone +45 45 830 900

 

Fax +45 45 830 444

 

 

www.siso.dk

 

[email protected]

 

VAT: DK 24786013

 

3. Other instructions

 

3.1 Acoustic & optic notifications

 

Note 1: Replacing battery when it is in low power 

-

 during the low power condition, user can still unlock for 500 

times.

 

Note 2: Three times input the code incorrectly will cause alarm sounds for 60 seconds. Once the correct code has 
been put in, the alarm will stop. 

 

3.2 Technical parameters

 

 

Working voltage

 

DC 2.3

-

3.3V

 

Battery SPEC

 

CR 1220

 

Standby current

 

≤ 2uA

 

Max. current

 

≤ 5mA and time of duration ≤ 35ms

 

Battery life

 

1

-

2 years  unlock 30

-

50 times one day

 

Operation temp

 

-

5 degrees to +50 degrees Celsius

 

Relative humidity

 

20% to 80%

 

Material 

 

Zinc Alloy/ABS

 

Diameter of mounting

 

Apply to diameter 16mm

 

Panel Thickness

 

Steel: 0,5

-

12mm  Wood: 0,5

-

22mm

 

Certification

 

CE/FCC/PSE/ROHS/SGS/SST

 

No

 

Name

 

Sound notification

 

Explanation 

 

1

 

Button

 

Ti

--

 short sound

 

The "keypress" is effective

 

2

 

Unlocking change

 

Ti

----

long sound

 

Operation correct. Unlocking/change code successfully

 

3

 

Error

 

Ti Ti two sounds

 

Operation, error, input failure

 

4

 

Low power

 

Ti Ti Ti three sounds

 

Low power, replace a new battery

 

5

 

Alarm

 

Ti… alarm sounds

 

3 times wrong input will cause alarm sound for 60 seconds

 

Отзывы: