3
Electronic Combination Cam Lock ”Dave”
SISO A/S
Mileparken 11
DK
-
2740 Skovlunde
Denmark
Phone +45 45 830 900
Fax +45 45 830 444
www.siso.dk
VAT: DK 24786013
3. Other instructions
3.1 Acoustic & optic notifications
Note 1: Replacing battery when it is in low power
-
during the low power condition, user can still unlock for 500
times.
Note 2: Three times input the code incorrectly will cause alarm sounds for 60 seconds. Once the correct code has
been put in, the alarm will stop.
3.2 Technical parameters
Working voltage
DC 2.3
-
3.3V
Battery SPEC
CR 1220
Standby current
≤ 2uA
Max. current
≤ 5mA and time of duration ≤ 35ms
Battery life
1
-
2 years unlock 30
-
50 times one day
Operation temp
-
5 degrees to +50 degrees Celsius
Relative humidity
20% to 80%
Material
Zinc Alloy/ABS
Diameter of mounting
Apply to diameter 16mm
Panel Thickness
Steel: 0,5
-
12mm Wood: 0,5
-
22mm
Certification
CE/FCC/PSE/ROHS/SGS/SST
No
Name
Sound notification
Explanation
1
Button
Ti
--
short sound
The "keypress" is effective
2
Unlocking change
Ti
----
long sound
Operation correct. Unlocking/change code successfully
3
Error
Ti Ti two sounds
Operation, error, input failure
4
Low power
Ti Ti Ti three sounds
Low power, replace a new battery
5
Alarm
Ti… alarm sounds
3 times wrong input will cause alarm sound for 60 seconds