![sisel Supra H2 Ultra Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/sisel/supra-h2-ultra/supra-h2-ultra_product-manual_1285257004.webp)
WARNING
Filters must be replaced according to instructions in the attached
documentation. Failure to replace filters on schedule will effect system
performance and may damage the unit.
HOW TO REPLACE FILTERS
PREPARATION
Place machine on a dry towel to absorb excess
water which may spill.
Close water supply valve.
Remove remaining water pressure inside
filters by pressing the “Start” button until the
water stops flowing.
Disconnect power input jack from the product.
OPENING SIDE COVER
Remove 2 thumb screws located on back of
machine.
Slide the door toward the back of the machine
until door releases and can be removed.
REPLACING UF AND CARBON FILTERS
Grasp filter firmly and rotate counter-clockwise
until filter drops out. Insert new filter so that it
slides up into receptacle
(it will only fit one way).
Twist filter Clockwise until it is firmly seated.
Replace next filter using same procedure.
RECONNECT MACHINE
Open water supply valve.
Check each connection and fitting for any
leakage. If leak is found, tighten connection.
Reconnect power input jack from the product.
Run system for 5-10 minutes prior to the first
use after filter replacement.
REPLACE SIDE COVER
Slide the door forward from the back of the
machine until the door catches seat properly.
Replace and tighten 2 thumb screws located
on back of machine, being careful not to
over-tighten.
DISPOSAL
The construction and materials of the SupraH2 Ultra do not require special disposal
procedures. Simply follow the local requirements for the disposal of electrical and
electronic devices.
WATER FILTERING SYSTEM
WARNING
Before performing any type of maintenance, disconnect the device from
its power source.
OPERATION OF SUPRAH
2
ULTRA WATER SYSTEM
MAINTENANCE OF SUPRAH
2
ULTRA WATER SYSTEM
INITIAL OPERATION
Open black water supply valve.
Touch “Pure” or “H2” button, then press “Start” and check for water flow. Allow
water to flow for5-10 minutes before normal use.
Remove cover and check each part, connection and fitting for any leakage. Replace
cover and use.
HOW TO OPERATE
Place receptacle under water outlet.
Press “Pure” button for purified water or press H2 button
for Ion infused water.
Press and hold “Start” button until desired amount has
been dispensed.
The device should be kept clean and dry. Remove any dust or grime by using a soft
cloth moistened with water or a gentle, non-abrasive cleanser.
WARNING
FLUSH FILTERS!
During initial operation water may contain carbon particles, allow the
machine to run 5-10 minutes to flush these particles out. Failure to do so
may damage unit.
WARNING
Close water supply valve when the
product is not in use for more than 24
hours to prevent any damage due to
water leakage.
UF Membrane Filter
12 Months
Carbon Block Filter
6 Months
Removes minute particles and germs while maintaining
useful minerals in the water
Chlorine removal, water taste control and odor removal
Filter
Filter Function
Replace
Содержание Supra H2 Ultra