sisel Supra H2 Ultra Скачать руководство пользователя страница 4

WARNING
Filters must be replaced according to instructions in the attached 
documentation. Failure to replace filters on schedule will effect system 
performance and may damage the unit.

HOW TO REPLACE FILTERS

PREPARATION
Place machine on a dry towel to absorb excess 
water which may spill.
Close water supply valve.
Remove remaining water pressure inside 
filters by pressing the “Start” button until the 
water stops flowing.
Disconnect power input jack from the product.
 
OPENING SIDE COVER 
Remove 2 thumb screws located on back of 
machine.
Slide the door toward the back of the machine 
until door releases and can be removed.
 
REPLACING UF AND CARBON FILTERS
Grasp filter firmly and rotate counter-clockwise 
until filter drops out. Insert new filter so that it 
slides up into receptacle 
(it will only fit one way). 
Twist filter Clockwise until it is firmly seated. 
Replace next filter using same procedure.

RECONNECT MACHINE
Open water supply valve.
Check each connection and fitting for any 
leakage. If leak is found, tighten connection.
Reconnect power input jack from the product.
Run system for 5-10 minutes prior to the first  
use after filter replacement.
   
REPLACE SIDE COVER
Slide the door forward from the back of the 
machine until the door catches seat properly.
Replace and tighten 2 thumb screws located 
on back of machine, being careful not to  
over-tighten.

DISPOSAL
The construction and materials of the SupraH2 Ultra do not require special disposal 
procedures. Simply follow the local requirements for the disposal of electrical and 
electronic devices.

WATER FILTERING SYSTEM

WARNING
Before performing any type of maintenance, disconnect the device from 
its power source.

OPERATION OF SUPRAH

2

 ULTRA WATER SYSTEM

MAINTENANCE OF SUPRAH

2

 ULTRA WATER SYSTEM

INITIAL OPERATION

Open black water supply valve.
Touch “Pure” or “H2” button, then press “Start” and check for water flow. Allow 
water to flow for5-10 minutes before normal use.  
Remove cover and check each part, connection and fitting for any leakage. Replace 
cover and use.

HOW TO OPERATE

Place receptacle under water outlet.
Press “Pure” button for purified water or press H2 button 
for Ion infused water. 
Press and hold “Start” button until desired amount has  
been dispensed.

The device should be kept clean and dry. Remove any dust or grime by using a soft 
cloth moistened with water or a gentle, non-abrasive cleanser.

WARNING

 FLUSH FILTERS!

 

During initial operation water may contain carbon particles, allow the 
machine to run 5-10 minutes to flush these particles out. Failure to do so 
may damage unit.

WARNING

Close water supply valve when the 
product is not in use for more than 24 
hours to prevent any damage due to 
water leakage.

UF Membrane Filter

12 Months

Carbon Block Filter

6 Months

Removes minute particles and germs while maintaining 

useful minerals in the water

Chlorine removal, water taste control and odor removal

Filter 

Filter Function 

Replace

Отзывы: