Holding Register
addresses
Decimal (Hex)
Data
type
Data content
Parameter
Name
Read / Write
permission
inp.
disp.
st.ti.
ou.hi.
ou.lo.
cu.hi.
ou.of.
A.con.
A.out.
A.cnn.
d.adr.
R / W
R / W
R / W
R / W
R / W
R / W
R / W
R / W
R / W
R / W
R / W
R / W
Input selection (0: 4-20mA, 1: 0-20mA, 2: 0-10V, 3: 1-5V, 4: 2-10V,
5: 0-5V, 6: potentiometer
, 7: manual, 8: Modbus
).
Display selection on Run
ning
Mode (0: output as percent,
1: output as current, 2: set manually in percent output).
Kick-Soft start duration (adjustable between 0 and 200 seconds).
Max. acceptable value for output.
(
Acceptable between
ou.lo.
and
100
)
.
Modbus
device address
(adjustable between 0 and 247).
Max. output current. (Acceptable value between 0 and load current).
Output offset value. (Adjustable between -50 and 50).
Security parameter for configuration menu (0: Menu invisible,
1: Menu programmable 2: Only configuration menu visible).
Output parameter for configuration menu (0:Menu invisible,
1: Menu programmable 2: Only configuration menu visible).
Communication parameter for configuration menu (0: Menu invisible,
1: Menu programmable 2: Only configuration menu visible).
Modbus input (adjustable between
ou.lo.
and
ou.hi.
).
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
Byte
0012d (000Ch)
0011d (000Bh)
0010d (000Ah)
0009d (0009h)
0008d (0008h)
0007d (0007h)
0006d (0006h)
0005d (0005h)
0004d (0004h)
0003d (0003h)
0002d (0002h)
0001d (0001h)
0000d (0000h)
1.1 Memory Map for Holding Registers
1.2 Memory Map for Coils
Coil
addresses
Input register ad
dress
Data
T
ype
Data content
Parameter
Name
c.typ.
a.lou.
--
Err.c.
R / W
Only Readable
R / W
R / W
Control selection type (0: Phase angel, 1: Zero-cross)
Min. acceptable value for output. (acceptable between
0
and
ou.hi.
).
Output value as percent
Alar
m relay selection (0: NO, 1: NC)
Alarm control management (0: Returns to Run Mode when error
disappeares., 1: Remains in Eror Mode when error disappeares.)
Bit
Byte
Bit
Bit
(0000)h
(0000)h
(0001)h
(0002)h
1.3
Memory Map for
Input Register
s
--
Byte
ENDA ERPA1 MODBUS PROTOCOL ADDRESS MAP
Read / Write
permission
Data content
Parameter
Name
Read / Write
permission
Only Readable
Current value as percent
Output rate %20
Output rate %20
Output rate %50
Output rate %50
Output rate %80
Output rate %80
It is a proportional control method used in inductive and variable resistive loads
(cosØ <1). The disadvantage of this method is that it causes high electrical noise.
It is a control method used in capacitive and variable resistive loads (cosØ =1).
The advantage of this method is that it does not causes high electrical noise.
With Phase Angle Control
With Zero-Crossing Control
Start Method
t : Start time (
St.ti.
)
Output
Ratio
Max. 100
Max. 100
0
0
t
t
Second
Soft Start
Kick Start
Output Ratio : Manually set or changed
by the input signal is
output as a percentage.
Out
%
Control Method
Out
%
Output
Ratio
Second
Output Ratio : Manually set or changed
by the input signal is
output as a percentage.
t : Start time (
St.ti.
)
baud
R / W
Modbus baud rate (0: 1200, 1: 2400, 2: 4800, 3: 9600, 4: 19200)
Byte
00
13
d (000
D
h)
st.ty.
R / W
Start type selection. ( 0 : Soft Start according to input signal. 1 : Kick Start according to
input signal. 2 : Soft Start according to manual output. 3 : Kick Start according to manual output ).
Note : Modbus default Parity and Data Bits settings can not be changed. (Parity : None. Data Bits : 8)