The upper limit of the hysteresis value

Delay time for the upper limit alarm

The lower limit of the setpoint

The lower limit of the hysteresis value

Delay time for the lower limit alarm

Current conversion ratio

Measurement method (

0

=

AC

1

=

DC

2

=

ACDC

)

Decimal point. (0 = 

0

 , 1 = 

0.0

 , 2 = 

0.00

 , 3 = 

0.000

)

Baudrate (0=Off;1=1200;2=2400; 3=4800; 4=9600; 5=19200
6= 38400; 7= 57600; 8= 115200)

dlyU

L0Ll

HY5L

dLyl

HY5U

ctrr

typE

dpnt

OPTN

aDr5

BAUD

0.10

5.00

0

0.10

0

no

aCdC

0.00

4

1

 oFF

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

0000d

0001d

0002d

0003d

0004d

0005d

0x0000

0x0001

0x0002

0x0003

0x0004

0x0005

word

word

word

word

word

word

Measurement method (

0

=

AC

1

=

DC

2

=

ACDC

)

Baudrate (0=Off;1=1200;2=2400; 3=4800; 4=9600; 5=19200
6= 38400; 7= 57600; 8= 115200)

ctrr

typE

dpnt

0PTN

aDr5

BAUD

5

aCdC

0.00

4

1

9600

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Holding Register Parameter Table (For devices with “No Relay” and “A” type output models)

Device address for RS485 network connection.
Adjustable between 1-247.

Sampling time of the measurement value. If 1 is selected, it is
250ms. If 2 is selected, it is 500ms. If 3 is selected, it is 750ms.
If 4 is selected, it is 1 second.

Sampling time of the measurement value

Device address for RS485 network connection.
Adjustable between 1-247.

Holding Register 
      Addresses

Decimal

Hex

Data
Type

Data Content

Parameter
    Name

 Read/Write
Permission

Status
Value

0000d

0x0000

word

The upper limit of the setpoint

UPLL

Read / Write

5

HOLDING REGISTERS FOR R EXTENSION DEVICES

ENDA EPA242  DIGITAL AMPERMETER  MODBUS PROTOCOL ADDRESS MAP

0013d

0x000D

word

Read / Write

OUT1 output status

0tyP

0.00

0008d

0x0008

word

Read / Write

Delay Time for Initial Upper Limit Alarm

0

5dly

*

 0014d

0x000E

word

Input type  (

0=Ct20

1=Ct30

2

=

5Hnt

)

ityp

ct20

Read / Write

*

 0015d

0x000F

word

turn

1

Read / Write

* 14 and 15 Addresses are used only in devices with input type CT20/30.

Current conversion ratio

Decimal point. (0 = 

0

 , 1 = 

0.0

 , 2 = 

0.00

 , 3 = 

0.000

)

*

 0006d

0x0006

word

Input type  (

0=Ct20

1=Ct30

2

=

5Hnt

)

ityp

ct20

Read / Write

*

 0007d

0x0007

word

Analog output type (0=

0-20

 , 1=

4-20

 , 2= 

0-10

 ,3=

1-5

)

turn

1

Read / Write

Number of windings for transformer

Number of windings  for transformer

Atyp

Read / Write

0 - 20

**

 0008d

0x0008

word

*

   6 and 7  Addresses are used only in devices with input type CT20/30.

**

 8 Address is used only in devices with output type “A”.

In devices with input type CT20/30, following parameter settings will change automatically if the 

ityp

  parameter is changed.

If  

ityp

 = 

Ct20

 ; 

UpLL

 = 

300.0

 , 

LoLL

 = 

0

 , 

Hy5U

 = 

0.10

 , 

Hy5L

 = 

0.10

If  

ityp

 = 

Ct30

 ; 

UpLL

 = 

120.0

 , 

LoLL

 = 

0

 , 

Hy5U

 = 

0.10

 , 

Hy5L

 = 

0.10

0001d

0x0001

word

Decimal point of measured current value

--

Read Only

  Input Register 
      Addresses

Decimal

Hex

Data 
Type

Data Content

Parameter
   Name

Read/Write Permission

0000d

0x0000

word

 Measured current value

--

Read Only

INPUT REGISTERS FOR R EXTENSION DEVICES

  Discrete Input 
      Addresses

Decimal

Hex

Data 
Type

Data Content

Parameter
    Name

 00d

0x00

Bit

Relay output state (0=

OFF

; 1=

ON

)

--

DISCRETE INPUTS FOR R EXTENSION DEVICES

  Coil Addresses

Decimal

Hex

Data 
Type

Data Content

Parameter
    Name

 Read/Write 
Permission

 00d

0x00

Bit

Output state (0=

no

; 1=

nc

)

0typ

COILS FOR R EXTENSION DEVICES

Status
Value

Read Only

Read/Write Permission

Read / Write

Note 1 : 

Coil and Discrete input parameters are not available in the devices those have no relay

 

Note 2 :

 

0tyP

 menu parameters can be used as “Holding Register” or “Coil.

Note 3 :

 Value read in 0th address of input register gives the measured value. Also, the 1st address of the input register 

specifies the decimal part of the measured current value.
For example ;
Value read in 0th address of input register is 2842, if value read in 1st address from input register as 1, it is 284.2
Value read in 0th address of input register is 2842, if value read in 1st address from input register as 2, it is 28.42
Value read in 0th address of input register is 2842, if value read in 1st address from input register as 3, it is 2.842

 