OUTPUTS

 Auxiliary power supply 

 12V DC, max. 50mA (unregulated) or 8V DC, max. 50mA (regulated) or 5V DC max. 50mA (regulated)

In the current measurement mode input impedance is 5

W. 

Therefore, in the current measurement mode, any voltage input 

should not be connected to the input terminals. Otherwise, the device will be broken down.

 To change the input type from 

voltage to a current measurement mode while the device is operating, first,

 leave out the voltage inputs. Then, change 

input type to one of the current measurement modes. 

  EI741A  must not be used in location where measurement category is II, III or IV.

 * 72x72mm sized.
 * 4 digits display.
 * Easy to use by front panel keypad.
 * Display scale can be adjusted between -1999 and 4000.
 * Decimal point can be adjusted between 1. and 3. digits.
 * Measurement unit can be displayed.
 * Selectable four different standard input types (0-20mA, 4-20mA, 0-1V, 0-10V)
 * User can calibrate the device according to his/her own specified input type.
 * Sampling time can be adjusted in four steps. 
 * Maximum and minimum measurement values are registered.
 * The maximum or the minimum values can be hold on the display.
 * Current and voltage calibration can be made..
 * Parameter access protection on 3 levels.
 * Easy connection by removable screw terminal.

Supply Voltage

Order Code

Auxiliary Supply OUT 

230V AC  +10% -20%

EI741A

---------------

24V AC    10%

9-30V DC SMPS module

EI741A-ASXX
EI741A-24AC

EI741A-24DC

EI741A-24AC-ASXX

EI741A-24DC-ASXX

Present
------------—

------------—

Present

Present

SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ.
Yukarý Dudullu 

 34775 - ÜMRANÝYE/ÝSTANBUL-TÜRKÝYE

Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. Kutup Sok. No:20

 EI741A-E-05

Input type

 0-1V DC voltage

 0-10V DC voltage

 0-20mA DC current
 4-20mA DC current

 Input empedance

Approx. 11k

W

 (terminal voltage limits:  min. =  -2V,  max. = 30V)

Approx.

(terminal voltage limits:  min. =  -2V,  max. = 30V)

 11k

W

  

Approx. 5

W

  (applicable terminal voltage is max. 50mA.)

Approx.

(applicable terminal voltage is max. 50mA.)

 5

W

  

ENDA EI741A PROGRAMMABLE INDICATOR

 Thank you for choosing ENDA EI741A INDICATOR.

Read this document carefully before using this device. The guarantee will be expired by 
damaging of  the device if you don't attend to the directions in the user manual. Also we don't 
accept any compensations for personal injury, material damage or capital disadvantages.  

ENVIRONMENTAL CONDITIONS

 Height

 Max. 2000m

 Ambient/storage temperature

 Max. relative humidity

0 ... +50

 

°C/-25 ... +70°C  (with no icing) 

Rated pollution degree

TECHNICAL SPECIFICATIONS 

80% up to 31

decreasing linearly  50% at 40

°C °C

According to EN 60529                Front panel :    IP60
                                                       Rear panel  :    IP20

 Do not use the device in locations subject to corrosive and flammable gases.

 Supply

 230V AC +%10 -%20, 50/60Hz or 24V AC ±%10, 50/60Hz or optional 9-30V DC SMPS module.

 Power consumption

Max. 7VA
2.5mm² screw-terminal connections

 Wiring
 Date retention 
 EMC
 Safety requirements

 EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for the EMC standard)  

EEPROM (Min. 10 years)

 EN 61010-1: 2001 (pollution degree 2, overvoltage category II, measurement category I)

ELECTRICAL CHARACTERISTICS

HOUSING

 Housing type

 Suitable for flush-panel mounting according to DIN 43 700.

 Dimensions

 W72xH72xD97mm 

 Weight

 Approx. 350g (after packing)

 Enclosure material

 Self extinguishing plastics 

 While cleaning the device, solvents (thinner, benzine, acid etc.) or 

corrosive materials 

must not be used.

0V

±

0,5%

 

(of full scale

0V

±

0,5%

 

(of full scale

)

0mA

±

0,5%

 

(of full scale

)

0mA

±

0,5%

 

(of full scale

)

 1.1V

 14V
 25mA
 25mA

 Min.

Max.

Measurement range Measurement accuracy

NOTE :

Auxiliary Supply OUT:

XX: Indicates 

voltage.

Example: 
AS = 12V 50mA (unregulated)  

Auxiliary Supply 

AS08 = 8V DC 50mA (regulated) 
AS05 = 5V DC 50mA (regulated)

ENDA

PROGRAMMABLE INDICATOR

PRG

SHIFT

MIN.

MAX.

UNIT

RESET

D.P.

SET

EI 741A

Отзывы: