SN: XXXXXXXXX
EI14
1
0-NTC-12
NTC TEMPERATURE INDICATOR
ENDA
INDUSTRIAL ELECTRONICS
12V AC/DC
±
10%
50/60Hz 4VA
1
2
3
4
5
6
7
8
9 10 11 12
NTC
SENSOR
SN: XXXXXXXXX
EI14
1
0-NTC-24
NTC TEMPERATURE INDICATOR
ENDA
INDUSTRIAL ELECTRONICS
24V AC/DC
±
10%
50/60Hz 4VA
1
2
3
4
5
6
7
8
9 10 11 12
NTC
SENSOR
8 680407 703623
Made in Turkey
Made in Turkey
8 680407 703630
SN: XXXXXXXXX
EI14
1
0-NTC-230VAC
NTC TEMPERATURE INDICATOR
ENDA
INDUSTRIAL ELECTRONICS
230V AC +10% -20%
50/60Hz 4VA
1
2
3
4
5
6
7
8
9 10 11 12
NTC
SENSOR
8 680407 703616
Made in Turkey
2/3
DIMENSIONS
CONNECTION DIAGRAM
ENDA EI1410
intended purpose. The electrical connections must be carried on by a qualified staff and must be
according to the relevant locally applicable regulations. During an installation, all of the cables that are
connected to the device must be free of electrical power. The device must be protected against
inadmissible humidity, vibrations and severe soiling. Make sure that the operation temperature is not
exceeded. The cables should not be close to the power cables or components.
is intended for installation in control panels. Make sure that the device is used only for
7
8
SUPPLY:
NOTE :
184-253V AC
50/60Hz 4VA
Line
Neutral
230V AC
Supply
Switch
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should be connected.
1) Mains supply cords shall meet the requirements of
IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power
supply switch shall bring the identification of the relevant
instrument and it should be easily accessible by the
operator.
UP.l1
UP.l1 HYS
-
LO.l1
LO.l1
HYS
+
Alarm
Input
t
t
When an alarm condition occurs, measured temperature value flashes on the display.
Equipment is protected througout
by DOUBLE INSULATION.
Holding screw 0.4-0.5Nm
Panel cut-out
Note :
1) Panel thickness should be maximum
7 mm.
2) There must be at least 60mm free space
behind the device,otherwise it would be
difficult to remove it from the panel.
71,5mm
2
9
,5
m
m
Flush mounting
clamp
1
Depth
Panel
2
71mm
5mm
Rubber
packing
3
5
m
m
77mm
SET
°C
SET
E
i
141
0
ENDA
°F
For removing mounting clamps:
-
Push the flush-mounting clamp in direction
1
as
shown in the figure left.
-
Then, pull out the clamp in direction
2
.
SN
: X
XX
XX
XX
XX
EI1
4
1
0-N
TC
-2
30
VA
C
NT
C T
EM
PE
RA
TU
RE
IN
DIC
AT
OR
EN
DA
IN
DU
ST
RIA
L E
LE
CT
RO
NIC
S
23
0V
A
C +
10
% -
20
%
50
/6
0H
z
4V
A
1
2
3
4
5
6
7
8
9
10
11
12
N
TC
SE
NS
OR
86
80
40
77
03
61
6
Ma
de
in
T
urk
ey
EI
1
410-E-
10-R-201307
All manuals and user guides at all-guides.com