sisel ENDA EI1410 NTC Скачать руководство пользователя страница 2

SN: XXXXXXXXX

EI14

1

0-NTC-12

NTC TEMPERATURE INDICATOR

ENDA

 

INDUSTRIAL ELECTRONICS

12V AC/DC 

±

10% 

50/60Hz  4VA

1

2

3

4

5

6

7

8

9 10 11 12

    NTC
SENSOR

SN: XXXXXXXXX

EI14

1

0-NTC-24

NTC TEMPERATURE INDICATOR

ENDA

 

INDUSTRIAL ELECTRONICS

24V AC/DC 

±

10% 

50/60Hz  4VA

1

2

3

4

5

6

7

8

9 10 11 12

    NTC
SENSOR

8 680407 703623

      Made in Turkey

      Made in Turkey

8 680407 703630

SN: XXXXXXXXX

EI14

1

0-NTC-230VAC

NTC TEMPERATURE INDICATOR

ENDA

 

INDUSTRIAL ELECTRONICS

230V AC +10% -20%
50/60Hz  4VA

1

2

3

4

5

6

7

8

9 10 11 12

    NTC
SENSOR

8 680407 703616

      Made in Turkey

2/3

DIMENSIONS

CONNECTION DIAGRAM

ENDA EI1410
intended purpose. The electrical connections must be carried on by a qualified staff and must be 
according to the relevant locally applicable regulations. During an installation, all of the cables that are 
connected to the device must be free of electrical power. The device must be protected against 
inadmissible humidity, vibrations and severe soiling. Make sure that the operation temperature is not 
exceeded. The cables should not be close to the power cables or components.

  is intended for installation in control panels. Make sure that the device is used only for 

7

8

SUPPLY:

NOTE :

184-253V AC 
50/60Hz 4VA

Line

Neutral

230V AC
Supply 

Switch

Cable size: 1,5mm²

Fuse 

F 100 mA 

250V AC

Fuse should be connected.

1) Mains supply cords shall meet the requirements of
    IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power
    supply switch shall bring the identification of the relevant
    instrument and it should be easily accessible by the 
    operator.

UP.l1

UP.l1 HYS

 - 

LO.l1

LO.l1

HYS

 + 

Alarm

Input

t

t

When an alarm condition occurs, measured temperature value flashes on the display.

Equipment is protected througout 
by DOUBLE INSULATION.

Holding screw 0.4-0.5Nm 

Panel cut-out

Note :  

1) Panel thickness should be maximum

 

7 mm.

2) There must be at least  60mm free space 
    behind the device,otherwise it would be 
    difficult to remove it from the panel.

71,5mm

2

9

,5

m

m

Flush mounting 

clamp

1

Depth

Panel

2

71mm

5mm

Rubber
packing

3

5

m

m

77mm

SET

°C

SET

 E

i

141

0

ENDA

°F

For removing mounting clamps:  

-  

Push the flush-mounting clamp in direction 

1

 as                                            

shown in the  figure left.

-  

Then, pull out the clamp in direction 

2

.

SN

: X

XX

XX

XX

XX

EI1

4

1

0-N

TC

-2

30

VA

C

NT

C T

EM

PE

RA

TU

RE

 IN

DIC

AT

OR

EN

DA

 

IN

DU

ST

RIA

L E

LE

CT

RO

NIC

S

23

0V

 A

C +

10

% -

20

%

50

/6

0H

z  

4V

A

1

2

3

4

5

6

7

8

9

10

11

12

   

 N

TC

SE

NS

OR

86

80

40

77

03

61

6

   

   

Ma

de

 in

 T

urk

ey

EI

1

410-E-

10-R-201307

All manuals and user guides at all-guides.com