sisel Enda EDT5412A Скачать руководство пользователя страница 4

Decimal

Hex

0000d

0001d

0002d

0003d

0004d

0005d

0006d

0007d

0008d

0009d

0010d

0011d

0012d

0013d

0014d

0015d

0016d

0017d

0018d

0019d

0021d

0x0000

0x0001

0x0002

0x0003

0x0004

0x0005

0x0006

0x0007

0x0008

0x0009

0x000A

0x000B

0x000C

0x000D

0x000E

0x000F

0x0010

0x0011

0x0012

0x0013

0x0015

word

word

word

word

word

word

word

word

word

word

word

word

word

word

word

word

word

word

word

word

word

5Et

uPL

A.uPL

LoL

A.LoL

oFF

Hy

5

A.HY

5

5

nd

d.

i

np

dd

i

C.Pon

C.Fo

5

C.PPn

C.PPf

d.dur

d.

i

nt

d.dpo

d.d

rE

A.dfl

A.dpo

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Decimal

Hex

1.2 INPUT REGISTERS

0000d

0x0000

word

--

Decimal

Hex

1.3 DISCRATE INPUTS

0000d

0x0000

bit

--

d.d

rt

Read / Write

word

0x0014

0020d

0001d

0x0001

bit

--

07d

0x07

Bit

A.tYP

08d

0x08

Bit

Read / Write

Read / Write

Decimal

Hex

00d

0x00

Bit

o

.typ

Read / Write

1.4 COILS

01d

0x01

Bit

Unit

02d

0x02

Bit

D.PNT

03d

0x03

Bit

Dpo

04d

0x04

Bit

D.d

5

p

06d

0x06

Bit

D.poN

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

D

.5mt

05d

0x05

Bit

Read / Write

D

.typ

ENDA EDT5412A DIGITAL THERMOSTAT MODBUS PROTOCOL ADDRESS MAP

Data Content

Digital input types .0=

nd

;1=

EA

;2=

SA

;3=

df

;4=

lght

Set value

Set point upper limit

Upper level alarm

Set point lower limit

Lower level alarm

The offset value for the cooling

Cooling hysteresis

Switch hysteresis for alarm

Type of buzzer sound

Digital input delay

Delay time for the compressor after power is on.

On time for the compressor output in the case of probe failure

Off time for the compressor output in the case of probe failure 

Defrost duration

The time between 2 consecutive defrosts.

Delay time for defrosting after power is on.

After the cooling process of cooling start-up delay

Delay time required for the compressor to restart following  a stop.

Measured temperature value (

°

C / 

°

F)

Control output status (0=OFF; 1=ON)

Defrost / Lighting output selection.  OFF = 

dEf ,  

ON = 

Lght

Temperature unit.  OFF = 

°

C

  ,  ON = 

°

F

Decimal point . OFF=

no  , 

ON=

YE5

Digital input polarity. OFF = 

cL  , 

 ON = 

oP

Smart Defrost selection.   OFF = 

n

o

 ,  ON= 

YE5

Defrost type selection  OFF = 

ELC

  ,  ON = 

GAS

Data Content

Dripping (discharge) time

Time delay to display alarm message after power is on.

Data Content

Time delay to display alarm message after alarm is on.

Data Content

Defrost output status (0=OFF; 1=ON)

Alarm configuration.  OFF = 

Ab5

  ,  ON = Relative alarm  

rEF

Defrosting process begins with energy. OFF =  

no 

, ON = 

YE5

 

Display configuration during defrost. OFF = 

Lc

 , ON = 

rE

                                                       

1.1 HOLDING REGISTERS

Holding Register 
      Addresses

Data 
Type

Parameter 
    Name

Read/Write
Permission

Read

Read

Read

Read/Write
Permission

Read/Write
Permission

Parameter 
    Name

Parameter 
    Name

Read/Write
Permission

Parameter 
    Name

Data 
Type

Data 
Type

Data 
Type

Input Register 

Addresses

Discrate Inputs 

Addresses

    Coil
Addresses

4

/

4

EDT5412A-EN-01-191219

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
www.enda.com

Barbaros Cad. No:18

ENDA

TM

*

 Holding and Input Register parameters of type integer, those “signed integer” is defined as the decimal port of and associated with these parameters. (So,”14.0” is a parameter 

value of “140” will be read in). Relevant parameters for a period of “mm:ss” type ones in seconds, “hh:mm” while those species defined in minutes.

Отзывы: