background image

PLEASE KEEP THESE INSTRUCTIONS IN A

SAFE PLACE FOR FUTURE REFERENCE

USER INSTALLATION & SERVICE MANUAL

FOR: -

REMOTE    ECO 1& 2

DECORATIVE FUEL EFFECT APPLIANCE

THIS IS NOT A “DO-IT-YOURSELF” PRODUCT

THIS IS A 

NATURAL GAS 

(G20) APPLIANCE

FOR USE IN 

GB

 AND 

IE

 ONLY AT A SUPPLY

PRESSURE OF 20mbar.

Our policy is one of constant development and improvement.

Strict accuracy of illustrations and specifications is not guaranteed.

Modifications to design and materials may be necessary subsequent to publication.

Tel: (01282) 441 771  

eco

VII-11-09

Содержание REMOTE ECO 1

Страница 1: ...NOT A DO IT YOURSELF PRODUCT THIS IS A NATURAL GAS G20 APPLIANCE FOR USE IN GB AND IE ONLY AT A SUPPLY PRESSURE OF 20mbar Our policy is one of constant development and improvement Strict accuracy of illustrations and specifications is not guaranteed Modifications to design and materials may be necessary subsequent to publication Tel 01282 441 771 eco VII 11 09 ...

Страница 2: ...__________________ 2 GENERAL INSTALLATION REQUIREMENTS ___________________ 8 3 CHECK CARTON CONTENTS _______________________________ 4 THE FIREPLACE______________________________________ 5 GAS SUPPLY PIPE _____________________________________ 6 APPLIANCE INSTALLATION _________________________________ 6 7 CHECK FOR GAS SOUNDNESS____________________________ 10 6 8 FUEL BED ASSEMBLY _________________...

Страница 3: ... OR ANY OTHER COMBUSTIBLE MATERIAL IS 766mm FOR COMBUSTIBLE PROJECTIONS ABOVE 150mm DEPTH ADD 12 5mm TO THE ABOVE CLEARANCE FOR EVERY 25mm OF ADDITIONAL PROJECTION DEPTH 8 NEVER THROW PAPER OR OTHER MATERIAL ONTO THE FIRE 9 IT SHOULD BE APPRECIATED THAT ALTHOUGH THIS APPLIANCE CONFORMS TO ALL THE REQUIRED STANDARDS IT IS A DECORATIVE FUEL EFFECT HEATING APPLIANCE WITH AN OPEN FLAME AND CERTAIN PAR...

Страница 4: ...o more than 20 seconds TO SELECT THE REQUIRED FLAME LEVEL To turn down the fire point the handset to the sensor on your fire then push and hold the minus button small flame if you release immediately the flame will go to low if you hold the flame will lower slowly and you can release the button to your desired position To turn the fire up point at the sensor push the plus button until the desired ...

Страница 5: ...d the serial number Both of which can be found on the data badge which is located next to the control knob behind the ash pan cover A full service kit is available FUEL BED ASSEMBLY Using the two brackets supplied in the fixing kit included are two _ screws fold these brackets by hand with the black painted facing forward locate them into the two slots in the burner bracket and fix them in place u...

Страница 6: ...e back row As shown in figure 2A The Coals Pebbles MUST be placed sitting on top of the front ceramic resting between the pillars of the floor matrix as shown in fig 2A and fig 2B This allows the flame path to take its correct direction REAR MATRIX FRONT MATRIX REAR MATRIX FRONT MATRIX FLAME PATH Figure 2B VII 11 09 ...

Страница 7: ...is is due to a series of holes tailored in the hotbox top and canopy fixing face allowing fixture via two self tapping screws Canopy Fixing 1 Place canopy beneath the top of the Hotbox as shown in figure 2c taking care not scratch the paintwork 2 When fixing the canopy locate the fixing holes from beneath behind the canopy screwing up into the hotbox top figure 2d Figure 2c Figure 2d VII 11 09 ...

Страница 8: ...tic Gas Installations and the current building regulations 2 2 The appliance can be used in a builders opening or fireplace conforming to the sizes below The Minimum depth of the opening see Figure 4 dimension C in the case of the Hotbox Eco 1 2 only shall be 180mm and 200mm for the Convector box Eco 1 2 only The minimum front width see Figure 4 dimension A of the chairbrick opening shall be E1 41...

Страница 9: ...s not normally required for this appliance For use in I E ventilation must be in accordance with IS 813 2 15 It is essential that all decorative fenders have a minimum open area of 50cm_ to ensure adequate air supply for correct combustion 3 CHECK CARTON CONTENTS Check the contents are as follows 1 Burner Unit 1 Hotbox or Convector Box eco 1 2 only 1 Isolation Elbow with Nut Olive 1 Set of fuel ef...

Страница 10: ...rick dust and debris entering the pipe and causing a blockage or damage to valves and components 6 4 HAVE YOU PURGED THE GAS SUPPLY PIPES This is essential to expel any foreign matter that might be blown into the valve assembly injector or pilot etc and cause a blockage 6 5 Once the gas supply has been connected and purged then the burner assembly can be refitted in the reverse order to removal en...

Страница 11: ...actor fan is fitted in the same room as the appliance or a connecting room check that spillage does not occur with the fan operating all doors and other openings between the fan and the appliance open 9 FINAL CHECK AND CUSTOMER BREIFING 9 1 Instruct the customer on the full operation of the appliance 9 2 Advise the customer how to assemble the fuel effect as described in these instructions and tha...

Страница 12: ...the firebox sides see Figure 5 Figure 5 10 2 TO REMOVE THE THERMOCOUPLE ASSY a Follow 10 1 above to remove the burner tray b Disconnect the thermocouple connection from the control unit c Remove the pilot tube d Disconnect the spark electrode lead e Remove the two screws fixing the assy 10 3 TO REMOVE THE GAS VALVE a Follow 10 1 above to remove the burner tray b Disconnect the lead from the contro...

Страница 13: ...ay lit or fire goes out in use See Flame Failure Functional Check Uneven flame pattern e g flame at one side only 1 The fuel effect may need adjusting to even the flame pattern See page 6 Blue flames 1 The fire will burn blue on initial lighting until sufficient heat is generated causing the flames to burn yellow Typically 10 minutes 2 Insufficient gas pressure Check the supply pressure to the app...

Страница 14: ... Ensure there is no debris around the spark ignitor e g coal soot etc which could short the spark clean the area IGNITION FUNCTIONAL CHECK 2 NO Consult the User s section in this manual and retry YES Check for damaged or defective control knob spindle or cam operation Check for correct location of peizo components Correct and retry NO Is the valve being operated correctly NO Reset the electrode ga...

Страница 15: ...data badge NO Problem is with the pipework or fittings which lead to the fire YES Run for 3 mins turn off time interval until mag unit shuts with a click Is this greater than 7 seconds YES With the fire running on Full is the gas pressure as stated on the data badge Will the burner stay alight Light the burner and keep the control knob pushed in for 10 20 seconds before letting go Ensure there is ...

Отзывы: