Installation and User Instructions 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please ensure you read both the Fire and the Fascia instructions before starting the 

installation. 

All instructions must be handed to 

user for safekeeping 

This is not a DIY product and must be 

installed by a Gas Safe registered 

installer 

Edition D 05/17 

Country(s) of destination - GB/IE 

 

Eco4

 

MkIII

 

 

Содержание Eco4 MKIII

Страница 1: ...s Westerly Verto Installation and User Instructions Please ensure you read both the Fire and the Fascia instructions before starting the installation All instructions must be handed to user for safekeeping This is not a DIY product and must be installed by a Gas Safe registered installer Edition D 05 17 Country s of destination GB IE Eco4 MkIII ...

Страница 2: ...e and at the pressure stated on the appliance data plate After a new gas appliance excluding flueless cookers has been fitted the Building Regulations in England and Wales require that the installation must be notified to your Local Authority Your Gas Safe registered engineer needs to do this failure to register the appliance may affect your warranty OPENING THE APPLIANCE Stand the carton the righ...

Страница 3: ...ation 7 5 Site Requirements 7 to 9 5 1 Pre Fabricated Flue box 9 6 Debris Space 10 7 Installation of appliance 10 to 12 7 1 Preparing the Opening 13 to 15 7 2 Fitting the Burner Tray 16 to 17 8 Fuel Bed 17 to 22 9 Fitting the Outer Frame Trim 22 10 Commissioning the Appliance 23 10 1 Operating the Appliance 23 10 2 Spark Failure 23 11 Setting Pressure 24 12 Spillage Monitoring System 25 13 Testing...

Страница 4: ...and Consolidation Regulations issued by the Scottish Development Department BS 1251 BS 4543 part2 BS 5440 parts 1 2 BS 5871 part 3 BS 6461 parts 1 2 BS 6891 BS 8303 Failure to comply with these regulations could lead to prosecution and deem the warranty Invalid This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space Consult all instru...

Страница 5: ...ve height of at least three metres as measured from the hearth to the top of the flue Any flue damper plates or restrictors must be removed and no other restriction fitted to the flue Where removal is not practical the restriction must be fixed in the fully open position The flue must be connected to only one fireplace and the flue must not vent more than one appliance There must be no opening in ...

Страница 6: ...20 mbar 20 mbar Gas Inlet connection 8mm Compression 8mm Compression Overall Height 583 583 Overall Width 470 470 Overall Depth 119 139 Recess Height 548 548 Recess Width 320 320 Recess Depth 121 141 Air Vent N A N A Manual Slide Pilot Assembly Thermocouple Thermocouple T100 1332 250 Thermaco NG OXI PG 82 460 Valve CPMM 18700 357 Teddingtons TESA 3173 011 Injector STEREOMATIC 410 MULAK B STEREOMAT...

Страница 7: ... performance that cannot be corrected by any amount of ventilation For Republic of Ireland ventilation may be required see IS 813 ICP3 IS 327 and any other rules in force Section 5 SITE REQUIREMENTS The fireplace opening should be inspected and repairs made where necessary A chair brick or fireback may be left in place providing that the dimensional requirements for debris collection space and spi...

Страница 8: ...ed properly up the flue the outlet at the back of the appliance must have a 50mm minimum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the flue The fireplace or builders open must be reduced to suite the appliance both side to side and the full depth of the appliance a decorative back panel i e marb...

Страница 9: ...be in the form of a fender kerb hearth shelf or horizontal bar all made from non combustible material and fixed not less than 50mm not more than 1000mm above the floor level They should be positioned not less than 300mm in front of the appliance SECTION 5 1 PREFABRICATED FLUE BOXES This appliance can be fitted into a number of flue boxes provided that the minimum dimensions required for the applia...

Страница 10: ...USED OR PREVIOUSLY ONLY USED WITH A GAS FIRE Appliance recessed depth 20mm UNLINED FLUE OR CHIMNEY WHICH HAS BEEN PREVIOUSLY USED FOR A SOLID FUEL OR OIL BURNING APPLIANCE Appliance recessed depth 60mm Section 7 INSTALLATION OF APPLIANCE Always ensure that the gas supply is isolated before commencing installation of the appliance The fireplace opening and environment must be in compliance with spe...

Страница 11: ...ving the two screws shown in diagram below to the slide control then remove the burner from the assembly by removing the three screws at the base of the burner tray and undoing the connecting nut to the isolation tap on the side Diagram 3 NUT ISOLATION TAP SCREWS ...

Страница 12: ...holes are provided in the rear and side of the fire box for use where concealed pipe work is required Knock out the holes with a screwdriver and a sharp tap from a hammer and fit the rubber grommet supplied On the slide control option the position is located on the opposite side than shown Note DO NOT install or use the appliance without this seal in place Failure to fit this seal correctly will c...

Страница 13: ...flat and square to the wall or back panel and that the base level with the hearth as no leaks are permissible here At this stage it is essential to ensure that the spigot outlet of the fire is not obstructed in any way Remove the fire box and apply the self adhesive sealing strips around the edge of the rear of the firebox frame approximately 5mm in from the edge CABLE FIXING Using the template pr...

Страница 14: ...s in the top position and then through the one at the lower position back through the lower hole in the firebox as shown in the diagram Push the appliance back into the fireplace centralise and pull the loose cables through the hole into the firebox Open out Tab s with screwdriver to except the cable tie Through holes at the top of the fire box Through Screw eye at the bottom and through hole near...

Страница 15: ...or installation of the fire the gas supply can be routed as required and connected to the isolation tap via the 8mm compression fitting Note In no circumstance should you use soft soldered connections to or underneath the burner tray The isolator tap or restrictor elbow must be fitted to the incoming supply to facilitate servicing the gas pipe must be suitably protected where it passes through fir...

Страница 16: ...the front plate ensuring that the plate is in front of the front edge of the fire box Connect the gas supply and tighten the gas connections Note Please ensure that the electrode spark igniters gap on the manual version has not been misaligned during the handling of the burner in this installation the gap should be 5mm from the burner Connect the gas supply and tighten the gas connections With the...

Страница 17: ... the box Note Please ensure that the support brackets are level and that there is a minimum 5mm to 10mm gap between the burner and the bottom of the rear matrix this must not be touching the burner as this will cause the fire to burn incorrectly and cause damage to the fire and to malfunction Please note the position on the securing bracket and ensure this is not fixed upside down which will cause...

Страница 18: ...he back of the front matrix and the pilot assembly where applicable this is to ensure correct operating of the pilot and O D S system this must not be touching the assembly as this will cause the fire to operate incorrectly and cause damage to the fire and to malfunction BURNER FRONT MATRIX PILOT ASSEMBLY ...

Страница 19: ...e front row of 5 coals pebbles between the front coal support and the rear matrix as shown Now Place the second row as shown below coals may be rotated slightly within their positions to give a good visual effect ...

Страница 20: ...ive the best results Pay special attention to finally adjust the coals with the fire lit on the HIGH setting in order to ensure that no flames play onto the firebox sides This will reduce the possibility of heat discolouration Traditional Random coal bed option First identify the parts please see below COAL FRONT MATRIX 5 X COAL A 4 X COAL ...

Страница 21: ... does not touch the pilot assembly behind Place two B Coals at each end of the front matrix and the rear matrix as shown do not block the area between the coal supports Place the three coals A as shown again ensuring that the area between the coal supports is clear ...

Страница 22: ...tion With the three piece unit you should start with the side pieces of the clip on assembly these should be pushed into position first followed by the top bar which should overlap the sides IMPORTANT NOTE Due to the possibility of sharp edges care should be taken when handling the three piece frame components the use of protective gloves is recommended Place the fire front fret into position in f...

Страница 23: ...mm to produce a good spark There should be no need to adjust this If under any circumstances the electric spark fails the pilot may be lit manually by proceeding with the ignition sequence as previously described and after turning the control knob through the spark position the knob should be held in and the pilot lit with a taper Note Please ensure that the electrode spark igniters gap on the man...

Страница 24: ...uctions section 10 1 Check that the inlet gas pressure is at 20 mbar 1 mbar when the fire is at its highest setting Once the fire has been lit for 5 minutes turn the gas OFF at the isolating elbow After a further 3 minutes turn the gas supply ON again if the gas has stopped flowing the Flame Supervision Device FSD is operating correctly Always check that the gas has stopped flowing even if you hea...

Страница 25: ...y cleaned out on each annual service to ensure continued function of the ODS The spillage monitoring system shall not be adjusted modified or put out of operation by the installer Any spare parts fitted MUST be of a type supplied for the purpose by the appliance manufacturer If the fire is not spilling then further guidance should be sought using the Troubleshooting section as a guide SECTION 13 T...

Страница 26: ...as been completed satisfactorily repeat with any extractor fans in the premises running on the highest setting and any communicating doors open Finally repeat with all doors open DO NOT allows the fire to be used until the test is satisfactorily passed SCREWS First bend the spigot plate provided to approximately 70 The flue spigot restrictor is fixed into place with two screws from the front of th...

Страница 27: ...f the fire shuts down this system may be in operation If spillage is suspected SWITCH APPLIANCE OFF and call in the installer to investigate any problems SECTION 15 SERVICING First Isolate the fire from the gas supply and ensure that the fire is fully cold before attempting service Lay out the dust sheet and tools required Remove the cast front fret Carefully remove the ceramic components Remove t...

Страница 28: ...re restriction in gas supply clear obstruction Faulty thermocouple replace pilot unit Hold control knob in for longer Run through lighting system on the remote control several times allowing the valve to rest each time HT lead detached refit Spark gap too large or small reset correctly Spark shorting to metalwork under tray re align HT lead Excessive room draught or flue pull rectify Loose or faul...

Страница 29: ... the fire See relevant section for further details on clearances to combustibles No combustible material or flooring should protrude onto the hearth DO NOT burn any foreign material on this fire the coals must be of the correct type and lay out in accordance with the relevant section of these instructions Failure to do so could create a hazard or lead to sooting Before the appliance is installed t...

Страница 30: ... the spark click to the PILOT light position ensuring that the control knob is depressed and the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob depressed for approximately ten to fifteen seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ignition...

Страница 31: ...re has been turned off for any reason always WAIT FOR 3 MINUTES before attempting to re light The pilot is visible through the Fuel bed at the front of the fire rotate the coals for good viewing 1 From the standing position push the thumb control all the way to the bottom where a spark will be heard and generated hold down for approximately 15 seconds 2 Release the pressure and the pilot light sho...

Страница 32: ...S AND CERAMICS See the relevant section in the Installation Guide of these instructions SERVICING The fire and flue should be checked on an annual basis to ensure all of the products of combustion are entering the flue and that there is no excessive build up of soot The frequency of service will depend on usage but MUST be carried out at least once annually Servicing must be carried out by a compe...

Страница 33: ...ostly dealt with in the installation instructions DO NOT USE YOUR APPLIANCE and in the first instance contact your installer to investigate these further to establish their cause before contacting Sirocco CONTACTING SIROCCO FOR WARRANTY SERVICE OR TO PURCHASE SPARE PARTS In the event of a service or parts claim please note that some parts such as ceramics batteries trims and fronts etc are categor...

Страница 34: ...34 SECTION 20 LIST OF SPARES Eco 4 Manual Control 13 14B 11B 6B 1B 7B 8B 9B 10B 2B 15B ...

Страница 35: ...35 Eco 4 Slide Control 5D 3B 4D 3D 11D 13D 10D 2D 7D 8D 2D 9D 1D ...

Страница 36: ...36 Eco4 Ceramics 4A A1 A2 A4 ...

Страница 37: ...37 Eco4 Ceramics 10A ...

Страница 38: ...CO 2 3 BRA 460 11B BURNER NATURAL GAS PRT VAL BR E4 NG AE 41M 11B BURNER LPG GAS PRT VAL BR E4 LP AE 41M 13B ENGINE NATURAL GAS MANUAL EXCLUDING CERAMICS PRT E4 3 N M E 0 0 15B GAS INLET TUBE PRT VAL TU ECO 1 5 SI 1 TRIM 3 PART BRASS PRT DCF TR ECO 3PR SK BR TRIM 3 PART CHROME PRT DCF TR ECO 3PR SK CH TRIM 3 PART BLACK PRT DCF TR ECO 3PR SK BL 1D ENGINE SLIDE EXCLUDING CERAMICS PRT ECO 4 N SL E 0 ...

Страница 39: ... Delta Ltd Lodestar Delta Ltd T A Sirocco Unit 1 11 Weir St Blackburn Lancashire BB2 2AN SIROCCO HEAD OFFICE Telephone number for all departments 0843 289 4268 charged at BT national rate Mon to Fri 10 00 to 15 00 Contact us by email adminuk siroccofire pl View our latest products and use our on line services www siroccofires com Nad Lasem 8 Zabia Wola 96 321 Zelechow Poland WARRANTY AND SERVICE F...

Страница 40: ...t parts are given to an engineer for a service visit Please ensure you provide this to us within 28 days stated and include the Gas Safe notification number or your warranty will not be valid Regular Servicing It is essential that your Sirocco appliance is serviced by a suitably qualified Gas Safe engineer or a Sirocco authorised appointed engineer to carry this out at least within each twelve mon...

Страница 41: ...his guarantee nor shall the company assume responsibility for same Furthermore the company will not be responsible for any incidental indirect or consequential damages except as provided by law All other guarantees expressed or implied with respect to the product it s components and accessories or any obligations or liabilities on the part of Sirocco Fires are hereby expressly excluded Sirocco Fir...

Страница 42: ...AME ADDRESS POST CODE YOUR INSTALLER MUST COMPLETE ALL SECTIONS IN THIS PART AND SIGN THE FORM NAME ADDRESS TEL NUMBER GAS SAFE REG NUMBER THE WORKING PRESSURE OF THE FIRE IS on high setting mbar THE STANDING PRESSURE OF THE FIRE IS mbar GAS RATE FLUE SPILLAGE TEST PASS FAIL FLUE FLOW TEST PASS FAIL DOES VENTILATION MEET APPLIANCE REQUIREMENTS YES NO SIGNED BY INSTALLER PRINT NAME DATE PLEASE KEEP...

Страница 43: ...43 FOLD HERE SIROCCO Sp Zo o C O UNIT 1 THE WEIRS 11 WEIR STREET BLACKBURN LANCASHIRE BB2 2AN PLEASE AFFIX STAMP HERE ...