USES
PANEL OPENING
It is possible to open the panel, which cover the
grease filters, slightly pulling the panel on a side,
as shown on fig. 1.
In order to make the hood working properly, it is
recommended to install the appliance at a distan-
ce of 2000 - 2100 mm from the floor.
Before starting the appliance installation, please
check that all components are not damaged, in
such a case contact your retailer and do not carry
out installation.
Furthermore, please read carefully all of the fol-
lowing installation instructions.
- Use an exhausting pipe whose maximum length
does not exceed 5 meters.
- Limit the no. of elbows in the piping, since each
elbow reduces the air capacity of 1 linear meter.
(Ex.: if you use no. 2 x 90 ° elbows, the length of
piping must not exceed 3 meters).
- Avoid abrupt direction changes.
- Use a 150 mm constant diameter pipe for the
whole length, or same section.
- Use piping approved by standards in force.
29
INSTALLATION
SLT972_4V - SLT974_4V
SLT979_4V
Take the product out of the packaging and place
it on a suitable surface: we Suggest to use a soft
material, such as a sponge or a cloth.
Open the glass panel , rotating it as shown in Fig.
1, and remove the grease filters.
Where you intend to install the appliance, you
must create a recess which will have a rectangu-
lar opening of:
SLT972 750x410mm
SLT974 815x465mm
SLT979 1050x645mm
The distance between the plasterboard and the
solid ceiling shall be between the following di-
mensions:
SLT972 : from 160 to 230mm
SLT974 : from 200 to 270mm
SLT979 : from 210 to 280mm
For longer distances it is advisable to make suita-
ble sturdy brackets that connect the hood to the
solid ceiling.
Adequate air ducting must be provided inside the
plasterboard niche and connected to the power
supply, which is necessary to supply the hood.
We suggest to complete the plasterboard niche
only after having completely installed the product,
in order to make all the connections (electrical
and to the air outlet pipe) easily.
Drill the holes in the solid ceiling, as shown in fig.
2 - 3 - 13, insert the plastic plugs into the holes
drilled and secure the brackets to the ceiling as
shown in 4. The brackets are telescopic, to allow
the excursion indicated in the previous point.
If you intend to orient the air outlet of the product,
in a different direction from that established in the
factory, you can dismantle the fan box (see fig.5),
acting on the eight fixing screws, then rotate and
position it as you want, restore the eight fixing
screws removed previously.
Содержание SLT972
Страница 2: ...2...
Страница 3: ...3 3 2 1...
Страница 4: ...4 5 7 8 6 9 4...
Страница 5: ...5 11 10 12...
Страница 6: ...6 14 13...
Страница 7: ...INDICE Avvertenze Sistema d uso Installazione Funzionamento Manutenzione IT 7...
Страница 27: ...CONTENTS Warnings Uses Installation Working Maintenance GB 27...
Страница 40: ...40 10 In case of following error Go back to the home page TAP Claim Devices...
Страница 47: ...47...
Страница 48: ...90009721974 EM 02 21...