background image

3

For 1500mm versions, a comprehensive list of 
300mm components is available at  
www.siriusbrand.com or contact nearest retailer.

Min. 1200mm - Max. 1600mm from the barbecue 
grill surface for alfresco installations.

Min. 600mm - Max. 900mm 

for induction cooktops.

Min. 650mm - Max. 900mm

 gas cooktops.

If the rangehood is positioned above the max height 
recommended, warranty may be compromised 
as performance of the rangehood will be affected.
Measurement is taken from the top of the trivets to 
the underside of the hood. (Fig. 1)

•  The air being drawn can’t be conveyed through 

or into a duct used to let out fumes from 
appliances fed by energy other than electric 
power (eg. centralized heating, radiators, water 
heaters, etc.).

•  Attention: remove any possible PVC film from the 

stainless steel, including the filters.

•  To externally vent, please comply with the 

pertaining rules given by competent authorities.

•  Provide the room with an adequate ventilation 

when a rangehood and appliances fed by energy 
other than electric power (gas, oil, or coal stoves, 
etc.) are used simultaneously. The rangehood, 
when evacuating the air, could generate a 
negative pressure in the room which can’t exceed 
the limit of 0.04 mbar, in order to avoid the 
suck of exhausts deriving from the heat source. 
Therefore the room should be provided with air 
intakes to allow a constant flow of fresh air.

If the rating label in the rangehood shows the symbol       
    , the appliance is built in class II° and it 

does not 

need

 any earth connection.

If the rating label in the rangehood does not show 
the symbol     , the appliance is built in class I° and it 

needs

 the earth connection.

When performing the electrical connections on the 
appliance, please make sure that the current-tap 
is provided with earth connection and that voltage 
values correspond to those indicated on the label 
placed inside the appliance itself. 

When ducting rangehood, options are as follows:

Roof vent - EASYROOF 200T/M  
(for 850 & 1200 versions) 

*Kit includes roof flashing

Download installation guide

Eave vent - EASYEAVE 200 (for 850 & 1200 versions)

Download installation guide

Wall vent - EASYWALL 200 (for 850 & 1200 versions)

Download installation guide

Before carrying out any cleaning or maintaining 
operations, the appliance needs to be switched off. 
If the appliance is not provided with a non-separable 
flexible cable and plug, or with another device 
ensuring omnipolar disconnections from the grid, 
with an opening distance between the contacts of at 
least 3mm, then such disconnecting devices must be 
supplied within the fixed installation.
If the fixed appliance is endowed with a supply cord 
and a plug, the appliance has to be put in a place 
where the plug can be reached easily.

The use of materials which can burst into flames 
should be avoided in close proximity of the appliance. 
When frying, please pay particular attention to fire 
risk due to oil grease. Being highly flammable, fried 
oil is especially dangerous. Do not use uncovered 
electric grills. In order to avoid possible fire risk, all 
instructions for grease-filter cleaning and for removing 
eventual grease deposits should be strictly followed.

WARNING

1200mm - 1600mm (alfresco)

600 - 900mm (induction)

650 - 900mm (gas)

1200mm - 1600mm (alfresco)

600 - 900mm (induction)

650 - 900mm (gas)

(Fig. 1)

(Fig. 2a)

(Fig. 2b)

(Fig. 2c)

SIDE VIEW

FRONT VIEW

Dome 
featured on 
200mm kit 
only

Содержание SL920 FRESCO Series

Страница 1: ...ANGEHOOD INSTALLATION INSTRUCTIONS Congratulations on your purchase Thank you for choosing a Sirius product SL920 FRESCO 850 EAN 9351116002022 SL920 FRESCO 1200 EAN 9351116002039 SL920 FRESCO 1500 EAN...

Страница 2: ...then charges will apply for service and parts Flexible ducting is not permitted under any circumstances Flexible ducting has been found to increase noise levels increase vibration and reduce airflow...

Страница 3: ...e is built in class I and it needs the earth connection When performing the electrical connections on the appliance please make sure that the current tap is provided with earth connection and that vol...

Страница 4: ...ace area Before installing the appliance in order not to damage the appliance itself the metal grease filter should be removed These filters could be removed by pushing the handles towards the back si...

Страница 5: ...t other screws along the front or rear of the product as shown in Fig 7 This is not absolutely necessary if the cutout is the correct depth 7 Insert the grease filter Before connecting any ducting to...

Страница 6: ...ng is done Induction cooking with frequent boiling will create more condensation Filters may require to be dried more frequently To clean the appliance itself water and detergent are recommended while...

Страница 7: ...cy 433 92 Mhz Combinations 32 768 Max consumption 25 mA Operating temperature 20 55 C Dimensions 120 x 45 x 15 mm OPERATING DESCRIPTION The transmitter is equipped with 5 buttons for cooker hood manag...

Страница 8: ...m All efforts have been made to ensure that the information provided in this brochure is correct at the time of printing Due to continuous product improvement and ongoing development Sirius reserves t...

Отзывы: