The SEM71 motor is designed to exhaust fumes and 
odours silently and effectively. It must be installed on an 
external wall a minimum of 500mm from the ground and 
connected to the rangehood.

Note: due to OH&S regulations if the SEM71 motor 
is positioned higher than 2 metres from the ground, 
additional servicing costs may incur. Please note, 
motor must be accessible for servicing.

Note: due to the noise of the motor itself once installed, be 
sure to check that if it is located close to a boundary fence 
or you are in a built up area that you have checked with 
neighbours or local council regulations prior to installation.

•  Note: the SEM71 motor cannot be installed  

back-to-back with the rangehood.

Motor/ducting and electrical connection installation

•  Please note that the SEM71 motor must be installed at 

a minimum distance of 2 metres from the outlet collar 
on the rangehood. A maximum of 7 metres must not 
under any circumstances be exceeded. All SEM71 
motors come fitted with a 7metre long control cable.

1.  The installation of the SEM71 motor must only be 

made by a qualified technicial/tradesperson. Where 
possible use a Sirius recommended installer. (See 
www.siriusbrand.com for a list under the support tab)

2.  After predetermining the location of the motor, make 

sure you are within the recommendations above in 
regards to min/max distances. Use the supplied drill 
hole template that is supplied with the SEM71 motor 
and drill support holes, paying careful attention to 
make sure that the area behind is clear of electrical 
cables and/or piping & plumbing. These holes are to 
be drilled with an 8mm drill bit.

3.  210mm diameter hole to be cut into house for 200mm 

ducting. Please note that if a solid masonary block wall 
or brick wall is being used thaty a series of holes may 
need to be drilled and then the remainder of the hole 
be knock out by hand with a hammer and chisel. If a 
masonary hole bit is available, this will provise the best 
result.

4.  A hole must also be made to contain the plastic pipe 

that the SEM71 wiring loom is fed through. 40mm hole 
is required. 40mm drill bit required.

5.  Remove the stainless steel body to expose the motor 

and fixing points by removing the external screws 
located on the outside of the SEM71 motor. (Fig.4)

6.  Run the length of semi-rigid/solid duct through the 

pre-cut and attach to the SEM71 collar. Secure in 
place with a URC-25/215 ring clamp, making sure it is 
fastened tightly and will not come off. Feed the cable 
from the motor though the 40mm plastic pipe at the 
same time.

7.  Lining up the fastening points with the pre-drilled holes 

secure the motor in place using the supplied plastic 
dowels and the supplied screws.

8.  Replace the stainless steel body by following the 

step 5 in reverse making sure that the holes line up 
perfectly to ensure the unit is sealed correctly. 

Do not 

silicone motor to the wall.

9.  Run the length of ducting back to the location of 

the rangehood and secure to the outlet collar on the 
rangehood using anouther URC25-215 ring clamp. 
 

10.  The SEM motor has a 7 metre long cable with 

colour-coded wiring. Follow the MOTOR WIRING 
CONNECTION instructions on page 4 of this manual 
to connect the motor to the rangehood.

11.  The SEM71 motor will draw power directly from the 

rangehood which needs to be plugged into a 10AMP 
powerpoint located within 1 metre of the rangehood.

SEM71 MOTOR

A

A

A

A

B

Screws

B

B

B

B

210mm

40mm

A

(Fig. 3)

(Fig. 4)

For full details, refer to installation template on page 11.

Содержание SEM11

Страница 1: ...1 Installation guide for SEM11 SEM21 SEM71 and SEM81 motors when Sirius ducting is used Full replacement warranty on parts and labour Year Warranty www siriusbrand com...

Страница 2: ...2...

Страница 3: ...ION 5 INSTALLING THE SEM11 MOTOR 6 SEM 1 MOTOR WIRING DIAGRAM 7 INSTALLING THE SEM21 MOTOR 8 SEM21 MOTOR WIRING DIAGRAM 9 INSTALLING THE SEM71 MOTOR 10 SEM71 MOTOR WIRING DIAGRAM 11 INSTALLING THE SEM...

Страница 4: ...ake sure that the appliance is disconnected from the electrical mains IMPORTANT INFORMATION BEFORE INSTALLATION OF YOUR SIRIUS RANGEHOOD Rangehood and SEM motor cannot be installed back to back There...

Страница 5: ...bout the ducting please contact Sirius on 1300 762 219 prior to installation BEFORE YOU INSTALL DUCTING INFORMATION Sirius warranty covers only Sirius product If you choose to install a non Sirius bra...

Страница 6: ...illing the holes insert the plastic dowels Fig 2A and then fix in place using the supplied screws Fig 2B Make sure you have taken note of the inwards and outwards arrows on the SEM motor and the motor...

Страница 7: ...7 SEM11 MOTOR WIRING DIAGRAM...

Страница 8: ...te that if a solid masonary block wall or brick wall is being used that a series of holes may need to be drilled and then the remainder of the hole be knocked out by hand with a hammer and chisel If a...

Страница 9: ...9 SEM21 MOTOR WIRING DIAGRAM...

Страница 10: ...e to be cut into house for 200mm ducting Please note that if a solid masonary block wall or brick wall is being used thaty a series of holes may need to be drilled and then the remainder of the hole b...

Страница 11: ...11 SEM71 MOTOR WIRING DIAGRAM...

Страница 12: ...or pre drilling of the holes 4 After pre drilling he holes insert the plastic dowels Fig 2A and then fix in place using the supplied screws Fig 2B Make sure you have taken note of the inwards and outw...

Страница 13: ...13 SEM81 MOTOR WIRING DIAGRAM...

Страница 14: ...14 NOTES...

Страница 15: ...Sirius s Total Peace of Mind Protection Plan Australian New Zealand 3 6 Year Protection Plan This guarantees your appliance for a full 3 years parts and labour 10 years for the off board motors coveri...

Страница 16: ...is warranty will not apply where a The fault is caused by accident misuse an infestation of insect and or vermin fire flood or the use of products not approved by Arisit Pty Limited b There has been a...

Отзывы: