Uplink

®

 LTE30VZ Installation & User’s Guide

Uplink

®

 LTE30VZ Installation & User’s Guide

Specifications (cont.)

RADIO

Frequencies

700/1700/1900 MHz

Sensitivity

-106 dB (typical)

ENVIRONMENTAL 

Temperature Range

-30° to +70° C

Humidity

0 to 95% non-condensing

PHYSICAL

Height

2.5 inches

Width

5.4 inches

Depth

10.5 inches

Содержание Uplink LTE30VZ

Страница 1: ...Uplink LTE30VZ LTE CAT M1 PRIMARY CELLULAR ALARM COMMUNICATOR Installation User s Guide ...

Страница 2: ...ronic or mechanical means such as photocopying recording or information storage and retrieval systems The material in this manual is subject to change without notice Uplink reserves the right to make changes to any software or product to improve reliability function or design Uplink is a registered trademark of Uplink Security LLC All other trademarks are the property of their respective owners PR...

Страница 3: ... 23 A General Considerations 12 B DIP Switch Settings 12 C LEDs 13 14 D Locating and Installing the LTE30VZ 15 E Connecting the LTE30VZ to the Alarm Panel 17 F Configuring Input 1 19 G Activating the LTE30VZ 21 H Programming and Central Station Reporting 22 I Default Event Email Messages 23 J Completing the Installation and Testing 23 Specifications 25 26 Appendix A Contact ID SIA Modem IIe IIIa2 ...

Страница 4: ...3 Uplink LTE30VZ Installation User s Guide ...

Страница 5: ...the phone line connection The Uplink LTE30VZ unit will intercept the alarm panel s digital dialer output when the panel has an event to report and communicate with the panel as if it were a central station alarm receiver Once the LTE30VZ completes a communications session with the alarm panel it will transmit the alarm information using the local LTE CAT M1 cellular communications network The Mode...

Страница 6: ...8 9 Uplink 888 987 5465 if you have any questions or need additional information C Panel to LTE30VZ Cable Supervision Monitors continuity of the cable connecting the panel s telephone dialer to the LTE30VZ This feature is activated through the website www uplink com or by calling Uplink Technical Support 1 888 9 UPLINK 1 888 987 5465 D Input The LTE30VZ has one programmable input This input can be...

Страница 7: ...Received Signal Strength Indication mode RSSI to assist in selecting the optimal mounting location for transmitting and receiving cellular radio signals J Easy Initiation Ships with a SIM card with easy activations available via the website at www uplink com or by calling Uplink Customer Service 1 888 9 UPLINK 1 888 987 5465 Requires the central station receiver phone number and or its IP address ...

Страница 8: ...system dealer or installer from whom they purchased the product Distributors dealers and installers with questions about Uplink s warranty and returns process are directed to contact Uplink Order Entry issuance of a Return Merchandise Authorization RMA number by Uplink is required as a condition prerequisite to the return of any Uplink products under the applicable product warranty IN NO EVENT SHA...

Страница 9: ...INK ARISING OUT OF OR RELATED TO AN UPLINK PRODUCT AND OR SERVICE WHETHER ARISING OUT OF OR RELATED TO BREAK OF CONTRACT TORT INCLUDING WITHOUT LIMITATION NEGLIGENCE OR PRODUCT LIABILITY OR OTHERWISE EXCEED THE TOTAL AMOUNT PAID OR PAYABLE TO THE ALARM SECURITY DEALER OR INSTALLER BY THE END USER CONSUMER FOR SAID PRODUCT AND OR SERVICE IN THE 12 MONTH PERIOD PRECEDING THE EVENT GIVING RISE TO THE...

Страница 10: ...installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determine...

Страница 11: ... set by both U S and international standards bodies The design of this module complies with the FCC guidelines and these international standards The FCC ID of this unit is N7NHL7800 For more information about RF exposure please visit the FCC website at www fcc gov The term IC before the certification registration number only signifies that the Industry Canada Technical Specifications were met The ...

Страница 12: ...PM ET excluding holidays Before calling technical support please ensure you have read the installation guide completely Technical support requires the caller to provide Login name Password Serial number of the LTE30VZ Uplink Security LLC 400 Interstate N Pkwy Suite 900 Atlanta Georgia 30339 888 9 Uplink 888 987 5465 www uplink com ...

Страница 13: ...move the unit to a location that gives him the best signal strength b Proximity to the alarm panel and where to route the LTE30VZ relay output that connects to an alarm panel input B DIP Switch Settings The LTE30VZ has a four position dipswitch The dipswitches function as follows SWITCH NO SETTING FUNCTION S1 Default Load OFF Normal Operations ON Load Defaults S2 OTA Operation OFF OTA configuratio...

Страница 14: ...atus OFF No DC Power GREEN Normal DC Power RED Low DC Power LED2 Panel hook status GREEN Panel On Hook GREEN Panel Off Hook LED3 Trouble State RED Output Relay Off Normal GREEN Output Relay Normal LED4 Network Connection Status GREEN Data Connected GREEN Awaiting Carrier Response RED No Data Connection RED No Cellular Connection LED5 Heartbeat GREEN Normal Operation RED Reload Factory Default Sett...

Страница 15: ...icator RSSI Mode by turning Dipswitch S4 to ON the five LEDs indicate the follow signal strength information INSTALLATION continued next page LED1 LED2 LED3 LED4 LED5 STEADY FLASHING INDICATION ON ON ON ON ON GREEN BEST ON ON ON ON GREEN BETTER ON ON ON GREEN GOOD ON ON GREEN FAIR ON GREEN POOR ON RED BAD WEAK ON RED UNACCEPTABLE ...

Страница 16: ...propriate for this installation See DIP Switch Settings page 12 4 Place Dipswitch 4 S4 in the ON position The LEDs are now operating in RSSI Mode Locate a good mounting position based on a good Received Signal Strength Indication RSSI It is recommended that the installation location demonstrate an RSSI of at least 80 dBm two solid green LEDs The minimum acceptable RSSI is 90 dBm 1 solid green LED ...

Страница 17: ...n User s Guide Installation cont FIGURE 1 Model LTE30VZ PC Board Details STATUS LEDS INPUT OUTPUT DC TERMINAL BLOCK INSTALLATION continued next page CAUTION Incorrect Connections May Result in Damage to the Unit DIP SWITCHES RJ 45 ...

Страница 18: ... that can be used to activate an input on the alarm panel or for other local purposes Decide on how to use this output see section 6 Programming then wire it from the terminal strip to the external panel or device Output 1 Terminals OUT1 and OUT1 The default state for this Output is as follows OUTPUT DEFAULT STATE DEFAULT DEFINITION 1 Configurable normally closed Loss of cellular service See Figur...

Страница 19: ...18 Uplink LTE30VZ Installation User s Guide INSTALLATION continued next page Installation cont FIGURE 2 Connections between the LTE30VZ and the Alarm Panel LTE30VZ ...

Страница 20: ... fire signal and a steady voltage as a burglary signal It may be necessary to place a 1K Ohm resistor in parallel to prevent false alarms when using panels with supervisory voltage on the bell circuit Some panels with supervised bell circuits may require a 1K Ohm resistor in the circuit Contact Technical Support for further details 3 Sampled Siren This mode configures the unit to be tripped from a...

Страница 21: ... set for standard input can be tripped by applying 12 V to the input and 0 V to the input A signal must be continuously present for 500 ms FIGURE 4 Wiring example for open collector trip Open Collector Inputs 1 if set for standard input can be tripped by applying 12 V to the input and the Open Collector output of the panel to the input A signal must be continuously present for 500 ms ...

Страница 22: ...tion Agreement 4 Enter the device serial number and select Activate 6 If you are offering Remote Services enroll the unit in Uplink Remote 7 You will be directed to the Edit Unit Settings page where you will enter all appropriate customer information 8 From the Central Station Notification drop down menu select the appropriate format 9 Enter the appropriate Central Station phone number and account...

Страница 23: ...efault 1 Energized Open The normal state of the Output Relay can be changed from the dealer website 4 Output Relay 1 Mapping There are 6 trouble states that can be declared by the LTE30VZ and each of these states can be programmed from the dealer website to activate the Output Relay The 6 trouble states are Cellular Network Loss No Central Station Acknowledgement Low DC input Voltage Panel LTE30VZ...

Страница 24: ...intercepted the panel s digital dialer output and reported the event to the central monitoring station c If using the Output Relay on the LTE30VZ go back to the dealer website and use the Switch Output Relay command to test the relay Make sure the premises alarm panel properly detects the relay s change of state and that it reports the proper event to the monitoring central station d Finally remov...

Страница 25: ...24 Uplink LTE30VZ Installation User s Guide ...

Страница 26: ...ltage 48 V DC On Hook Dial tone 350 440 Hz 0 2 Receive level minimum 45 dBm 20 dBm S N Line impedance 600 ohms Ringer Equivalence 0 3 REN Mode Loop start 26 mA typical POWER REQUIREMENTS Input Voltage 12V DC Normal Current On Hook 125mA Maximum Current Off Hook 200mA Radio during Transmission Average Current Peak Current 115 210 mA 600 mA UL Power Requirements Uninterruptable Class 2 power supply ...

Страница 27: ...User s Guide Specifications cont RADIO Frequencies 700 1700 1900 MHz Sensitivity 106 dB typical ENVIRONMENTAL Temperature Range 30 to 70 C Humidity 0 to 95 non condensing PHYSICAL Height 2 5 inches Width 5 4 inches Depth 10 5 inches ...

Страница 28: ...l E301 AT 48 AC Restoral R301 AR 49 Alarm generic E140 UA 10 Burglary Alarm E130 BA 10 Burglary Restoral R130 BR 12 Burglary Tamper E137 TA 10 Burglary Tamper Restoral R137 TR 12 Closing R400 CL 32 Fire Alarm E110 FA 0B Fire Restoral R110 FR 0E Fire Supervisory E200 FS 11 Fire Supervisory Restoral R200 FJ 12 High Temperature E158 KA 10 High Temperature Restoral R158 KR 12 Holdup Alarm E122 HA 10 H...

Страница 29: ...400 OP 2F Panic Alarm E120 PA 10 Panic Restoral R120 PR 12 Phone Fail E350 LT 44 Phone Restoral R350 LR 45 Radio Supervision Lost E355 YC 11 Radio Supervision Restoral R355 YK 12 Restoral generic R140 UR 12 Service Completed R616 YZ 12 Service Required E616 YX 11 Telco Line Fail E350 LT 44 Telco Line Restoral R350 LR 45 Test E602 TX 33 Trouble generic E300 UT 11 Trouble Restoral generic R300 UR 12...

Страница 30: ...ult event codes sent by the LTE30VZ EVENT DESCRIPTION CONTACT ID EVENT CODE SIA DC 03 EVENT CODE MODEM IIe llla2 ZONE NO REPORTED Low DC Voltage E302 YT 4B 240 Low DC Restoral R302 YR 4C 240 Cable Supervision Trouble E616 YX 11 242 Cable Supervision Restoral R616 YZ 12 242 Cellular Service Loss E355 YC 11 243 Cellular Service Restoral R355 YK 12 243 LTE30VZ Unit Disabled E616 YX 11 245 LTE30VZ Uni...

Страница 31: ...LTE30VZ Installation User s Guide 2021 Uplink Security LLC All rights reserved Uplink is a trademark of Uplink Security LLC Uplink LTE30VZ LTE CAT M1 PRIMARY CELLULAR ALARM COMMUNICATOR Installation User s Guide ...

Страница 32: ...R SALES PRODUCT INFORMATION AND TECHNICAL SUPPORT Uplink Security LLC 400 Interstate N Pkwy Suite 900 Atlanta Georgia 30339 1 888 9 UPLINK 1 888 987 5465 Fax 1 888 542 9105 sales uplink com www uplink com ...

Отзывы: